Musikhaus Thomann
Thomann GmbH
Hans-Thomann-Straße 1
96138 Burgebrach
Deutschland
Telephone: +49 (0) 9546 9223-0
E-mail: info@thomann.de
Internet: www.thomann.de
20.07.2017, ID: 376918 (V2)

Table of contents
1 General notes............................................................................................................................................... 4
1.1 Further information........................................................................................................................... 5
1.2 Notational conventions.................................................................................................................... 6
1.3 Symbols and signal words............................................................................................................... 6
2 Safety instructions..................................................................................................................................... 9
3 Features....................................................................................................................................................... 14
4 Installation and starting up................................................................................................................ 15
5 Connections and controls................................................................................................................... 20
6 Operating.................................................................................................................................................... 27
7 Technical specifications....................................................................................................................... 31
8 Plug and connection assignments.................................................................................................. 32
9 Cleaning....................................................................................................................................................... 33
10 Protecting the environment.............................................................................................................. 34
Table of contents
Fan-200 DMX
3

1 General notes
This manual contains important instructions for the safe operation of the unit. Read and follow
the safety instructions and all other instructions. Keep the manual for future reference. Make
sure that it is available to all those using the device. If you sell the unit please make sure that
the buyer also receives this manual.
Our products are subject to a process of continuous development. Thus, they are subject to
change.
General notes
wind machine
4

1.1 Further information
On our website (www.thomann.de) you will find lots of further information and details on the
following points:
Download This manual is also available as PDF file for you to download.
Keyword search
Use the search function in the electronic version to find the topics of
interest for you quickly.
Online guides
Our online guides provide detailed information on technical basics
and terms.
Personal consultation For personal consultation please contact our technical hotline.
Service
If you have any problems with the device the customer service will
gladly assist you.
General notes
Fan-200 DMX
5

1.2 Notational conventions
This manual uses the following notational conventions:
The letterings for connectors and controls are marked by square brackets and italics.
Examples: [VOLUME] control, [Mono] button.
Texts and values displayed on the device are marked by quotation marks and italics.
Examples: ‘24ch’ , ‘OFF’.
1.3 Symbols and signal words
In this section you will find an overview of the meaning of symbols and signal words that are
used in this manual.
Letterings
Displays
General notes
wind machine
6

Signal word Meaning
DANGER! This combination of symbol and signal word indicates an
immediate dangerous situation that will result in death or
serious injury if it is not avoided.
WARNING! This combination of symbol and signal word indicates a pos‐
sible dangerous situation that can result in death or serious
injury if it is not avoided.
NOTICE! This combination of symbol and signal word indicates a pos‐
sible dangerous situation that can result in material and
environmental damage if it is not avoided.
Warning signs Type of danger
Warning – high-voltage.
Warning – suspended load.
General notes
Fan-200 DMX
7

Warning signs Type of danger
Warning – danger zone.
General notes
wind machine
8

2 Safety instructions
This device is designed for generating an adjustable airflow in show applications. The device is
designed for semi-professional and professional use and is not suitable for use in households.
Use the device only as described in this user manual. Any other use or use under other oper‐
ating conditions is considered to be improper and may result in personal injury or property
damage. No liability will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intellectual
abilities and having corresponding knowledge and experience. Other persons may use this
device only if they are supervised or instructed by a person who is responsible for their safety.
Intended use
Safety instructions
Fan-200 DMX
9

DANGER!
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not
within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from
the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.
DANGER!
Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present. Never
remove any covers.
There are no user-serviceable parts inside.
Do not use the device if covers, protectors or optical components are missing or
damaged.
Safety
Safety instructions
wind machine
10

DANGER!
Electric shock caused by short-circuit
Always use proper ready-made insulated mains cabling (power cord) with a pro‐
tective contact plug. Do not modify the mains cable or the plug. Failure to do so
could result in electric shock/death or fire. If in doubt, seek advice from a regis‐
tered electrician.
WARNING!
Risk of injury caused by falling objects
Make sure that the installation complies with the standards and rules that apply
in your country. Always secure the device with a secondary safety attachment,
such as a safety cable or a safety chain.
The load capacity of trusses or other fixtures must be sufficient for the intended
number of devices. Not that the movement of the head places additional loads on
the load-bearing parts.
Safety instructions
Fan-200 DMX
11

NOTICE!
Operating conditions
This device has been designed for indoor use only. To prevent damage, never
expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and
strong vibrations.
NOTICE!
Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches
the voltage rating of the device and that the AC outlet is protected by a residual
current circuit breaker. Failure to do so could result in damage to the device and
possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long
periods of time to reduce the risk of electric shock or fire.
Safety instructions
wind machine
12

NOTICE!
Possible staining
The plasticiser contained in the rubber feet of this product may possibly react
with the coating of your parquet, linoleum, laminate or PVC floor and after some
time cause permanent dark stains.
In case of doubt, do not put the rubber feet directly on the floor, but use felt-pad
floor protectors or a carpet.
Safety instructions
Fan-200 DMX
13

3 Features
n Adjustable fan speed
n Adjustable inclination angle (180°)
n Control via DMX and via buttons and display on the unit
n Timer function
n 3 and 5-pin DMX connectors
n Lockable connectors (Power Twist) for self-supply and for supplying further devices
n Canned motor for use with foggers
n Omega brackets for truss mounting enclosed
n Power supply cable (Power Twist) included
Features
wind machine
14

4 Installation and starting up
Unpack and carefully check that there is no transportation damage before using the unit. Keep
the equipment packaging. To fully protect the device against vibration, dust and moisture
during transportation or storage use the original packaging or your own packaging material
suitable for transport or storage, respectively.
Only lift the device by the base. Lifting it at the fan housing may damage the device.
You can install the device standing or hanging. When in use, the device must be mounted at a
solid surface or clamped to an approved truss.
Work from a stable platform whenever you install or move the device or when you perform
any kind of maintenance. Block access under the work area.
Installation and starting up
Fan-200 DMX
15

WARNING!
Risk of injury caused by falling objects
Make sure that the installation complies with the standards and rules that apply
in your country. Always secure the device with a secondary safety attachment,
such as a safety cable or a safety chain.
Mounting options
Installation and starting up
wind machine
16

The threads on the bottom are used for secure truss mounting of the device using omega
brackets. Additionally secure the device by a safety-rope against falling.
A Threads for attaching Omega brackets.
B Safety eyelet.
Installation and starting up
Fan-200 DMX
17

Create all connections while the device is off. Use the shortest possible high-quality cables for
all connections. Take care when running the cables to prevent tripping hazards.
NOTICE!
Possible data transmission errors
For error-free operation make use of dedicated DMX cables and do not use ordi‐
nary microphone cables.
Never connect the DMX input or output to audio devices such as mixers or ampli‐
fiers.
Wiring
Installation and starting up
wind machine
18

Connect the DMX input of the device to the DMX output of a DMX controller or another DMX
device. Connect the output of the first DMX device to the input of the second one, and so on
to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain
is terminated with a resistor (110 Ω, ¼ W).
Connections in DMX mode
Installation and starting up
Fan-200 DMX
19

5 Connections and controls
Front view
Connections and controls
wind machine
20

1 Operating panel with display.
2 Locking screw for fixing the fan housing.
3 Grab handle
Connections and controls
Fan-200 DMX
21

4 Display
5 [FUNCTION]
Button for selecting the setting parameter.
6 [UP]
Increases the displayed value by one.
Operating panel with display
Connections and controls
wind machine
22

7 [DOWN]
Decreases the displayed value by one.
8 [MANUAL]
Button for manually controlling the fan.
9 [VOLUME]
Button for adjusting the fan speed.
10 [TIMER]
Button to activate the TIMER mode.
Connections and controls
Fan-200 DMX
23

11 [POWER INPUT]
Lockable input socket (Power Twist) for power supply.
12 [POWER OUTPUT]
Lockable output socket (Power Twist) to supply further units.
13 [Fuse]
Fuse holder
14 [Voltage]
Main switch to turn the device on and off.
15 [DMX OUTPUT]
5-pin DMX output.
16 [DMX INPUT]
5-pin DMX input.
17 [DMX OUTPUT]
3-pin DMX output.
Connections and controls
Fan-200 DMX
25

6 Operating
To start up the device, connect it to the mains. The display shows consecutively ‘WELCOME’ ,
‘Version Vx.x’ and ‘AC
~
230V 50Hz’ . The device is then ready for use.
Press repeatedly [FUNCTION] until the display shows ‘Volume’ . In this mode you can use the
buttons [UP] and [DOWN] to adjust the fan speed in a range from ‘1’ … ‘9’.
The fan runs in continuous operation, the setting takes effect immediately and can be changed
any time.
Use the button [MANUAL] to control the fan manually. The fan runs with maximum speed as
long as you keep the button pressed.
Continuous operation
Manual operation
Operating
Fan-200 DMX
27

In DMX mode, the device is controlled by a DMX controller. The following table shows the
assignment of the three channels.
Channel Function Value
1 Fan speed 0% … 100%
2 Interval between two operating
phases
1m … 999m or 5s … 999s
3 Operating phase duration 1m … 999m or 5s … 999s
DMX operation
Operating
wind machine
28

Press repeatedly [FUNCTION] to consecutively call the various setting parameters for timercontrolled and DMX operation (see following table). Adjust the respective value using the but‐
tons [UP] and [DOWN] to adapt the values).
Parameter Function
‘IntervalSet’ Interval between two operating phases, value range
‘1m’ … ‘999m’ or ‘5s’ … ‘999s’ depending on the setting of
‘TimingSet’ .
‘DurationSet’ Operating phase duration, value range ‘1m’ … ‘999m’ or
‘5s’ … ‘999s’ depending on the setting of ‘TimingSet’.
‘VolumeSet’ Fan speed, value range ‘1’ … ‘9’.
‘DMX512’ DMX address, value range ‘1’ … ‘512’.
‘TimingSet’ Time unit selection for parameters ‘IntervalSet’ and
‘DurationSet’ , value range minutes ‘MIN’ and seconds ‘SEC’.
Timer-controlled operation,
DMX operation
Operating
Fan-200 DMX
29

If you don't press any button for about 15 seconds, the display shows the first setting param‐
eter ‘IntervalSet’ again.
Press [TIMER] to start the timer-controlled operation. The display shows the settings
‘IntervalSet’ and ‘DurationSet’.
Or connect a DMX controller to control the device after respective address assignment.
Operating
wind machine
30

7 Technical specifications
Inclination angle of fan housing
180°
Air flow rate
34 m3/min @ 2100 min
-1
Noise generation approx. 70 dB/1m
Power consumption 200 W
Operating supply voltage
AC 230 V 50 Hz
Fuse 5 mm × 20 mm, 12 A, 250 V, fast-acting
Dimensions (W × H × D) 430 mm × 460 mm × 400 mm
Weight 9.8 kg
Technical specifications
Fan-200 DMX
31

8 Plug and connection assignments
This chapter will help you select the right cables and plugs to connect your valuable equip‐
ment so that a perfect light experience is guaranteed.
Please take our tips, because especially in ‘Sound & Light’ caution is indicated: Even if a plug
fits into a socket, the result of an incorrect connection may be a destroyed DMX controller, a
short circuit or ‘just’ a not working light show!
The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please
refer to the drawing and table below for the pin assignment of a suitable XLR plug.
Pin Configuration
1 Ground, shielding
2 Signal inverted (DMX–, ‘cold signal’)
3 Signal (DMX+, ‘hot signal’)
Introduction
DMX connections
Plug and connection assignments
wind machine
32

9 Cleaning
Clean the device components that are accessible from the outside regularly. The cleaning fre‐
quency depends on the operating environment: damp, smoky or particularly dirty environ‐
ments can cause greater accumulation of dirt on the device components.
n Clean with a dry soft cloth.
n Stubborn dirt can be removed with a slightly dampened cloth.
n Never use solvents or alcohol for cleaning.
The fan grids of the device must be cleaned on a regular basis to remove dust and dirt. Before
cleaning, switch off the device and disconnect AC-powered devices from the mains. Use a lintfree damp cloth for cleaning. Never use solvents or alcohol for cleaning.
Device components
Fan grids
Cleaning
Fan-200 DMX
33

10 Protecting the environment
For the transport and protective packaging, environmentally friendly materials have been
chosen that can be supplied to normal recycling.
Ensure that plastic bags, packaging, etc. are properly disposed of.
Do not just dispose of these materials with your normal household waste, but make sure that
they are collected for recycling. Please follow the notes and markings on the packaging.
This product is subject to the European Waste Electrical and Electronic Equipment Directive
(WEEE). Do not dispose with your normal household waste.
Dispose of this device through an approved waste disposal firm or through your local waste
facility. When discarding the device, comply with the rules and regulations that apply in your
country. If in doubt, consult your local waste disposal facility.
Disposal of the packaging mate‐
rial
Disposal of your old device
Protecting the environment
wind machine
34

Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de