thomann expolite tourled pro User Manual

Page 1
Page 2
3.6--DMX512 SETTINGS....................................................................11.
PART 4 USING A DMX512 CONTROLLER....................................14.
4.1--BASIC ADDRESSING.................................................................14.
4.2--CHANNEL ASSIGNMENT............................................................14.
4.3--BASIC INSTRUCTIONS FOR DMX512 OPERATION......................19.
PART 3 DISPLAY PANEL OPERATION.........................................8.
3.1--BASIC..........................................................................................8.
3.4--ACTIVATING AUTO PROGRAMS.................................................10.
3.7--PERSONALITY...........................................................................11.
3.8--ID ADDRESS..............................................................................11.
3.10--SPECIAL SETTINGS.................................................................12.
3.13--A CTIVATE THE PASSWORD .................................................... 13.
3.9--EDITING CUSTOM PROGRAMS ................................................ 12.
3.12--WHITES BALANCE .................................................................. 13.
PART 1 PRODUCT (GENERAL)....................................................1.
1.1--PRODUCT INTRODUCTION.........................................................1.
1.2--PRODUCT FEA TURE S.... .... ...... .... .... ...... .... .... .... ...... .... .... .... ...... .1.
1.3--TECHNICAL SPECIFICATIONS.....................................................2.
1.4--PHOTOMETRIC DATA..................................................................3.
1.5--SAFETY WARNING......................................................................4.
PART 2 INSTALLATION...............................................................5.
2.1--MOUNTING...................................................................................5.
2.3--SETTING UP WITH A DMX512 CONTROLLER.................................6.
2.3-1--DMX512 ADDRESSING WITHOUT ID ADDRESSING................................ ......6.
2.3-2--DMX512 ADDRESSING WITH ID ADDRESS..................................................6.
2.2--POWER CONNECTION..................................................................5.
3.3--EDIT STATIC COLOUR...............................................................10.
PART 5 APPENDIX......................................................................20.
5.1--TROUBLE SHOOTING...............................................................20.
5.2--MAINTENANCE......................................................................... 21.
3.5--RUN MODE................................................................................ 10.
3.11--WHITES SETTING ....................................................................13.
ABLE OF CONTENTS
T
5.2 MAINTENANCE
21
5 APPENDIX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1 2 3 4 5 6 7 8
9 10 11 12 13 14
Front cover Rubber seal Clear glass Lens completed set LED PCB Heat sink Bracket Power connection board Display PCB Display protection metal plate Safety chain board Driver PCB POWER PCB (5V) Power supply (24V)l
No
ITEM
2010.1.15
Page 3
1.1 PRODUCT INTRODUCTION
This product is designed for indoor or outdoor use. Suitable applications include wash or effect lighting for architectural, stage,theatre or road show applications. Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller. This product can be operated as a single unit or in multiple units for large applications.
1.2 PRODUCT FEATURES
LED FIXTURE
1 PRODUCT(GENERAL)
1
* IP67 protection rating * RGBW Dimmer 0-100% * Strobe * Built-in automatic programs * Upload custom parameters to slave fixtures * LED display * Display control 'lock-out' * Direct DMX512 input * Independent ID address * Different white colors setting * 'Over-heat' protection
1 PRODUCT (GENERAL)
No display
SITUATION CAUSE
ACTION
5.1 TROUBLE SHOOTING
1) No power input
2) Power connection error
3) Display damaged
4) Display board IC error or power input connection error or two board connection error
5) Contrast decay
1) Check power supply
2) Check power connection
3) Replace display
4) Check the IC and all the connections
5) Adjust the LCD contrast
1) Display IC reverse install
2) Display IC damaged
1) Check Display IC installation and quality
LED MODULE on, but no control from display
Display normal, but no response from buttons
1) Buttons damaged
2) Display IC damaged
1)Replace buttons
2) Replace Display IC
1) Signal Cable error
2) Signal conncetion error
3) The DMX signal receive IC damaged
4) DMX address error
No DMX signal
1) Check all signal Cables
2) Check all signal conncetions
3) Check the DMX signal receive IC
4) Check DMX address
1) The heat sensor resistance of LED board error
2) The temperature protection circuit on the display error.
When the surface temperature of the unit exceed 75 , the temperature protection no work .
1) Replace the heat sensor resistance.
2) Check the temperature protection circuit.
1) Check LEDs joining
2) Check lens installing
1) LED not joining well
2) Lens not installing well
Color mixing uneven,with splash
1) LED damaged
2) LED damaged or Main PCB
LEDs of the same color are not lit
1) Replace LEDs
2) Replace damaged LED or Main PCB
1) Replace saving IC1) Saving IC damaged
Manual and program can not save
20
5 APPENDIX
5 APPENDIX
1) Check driver current of the partial color LEDs on the Driver PCB
2) Check LED quality
3) Reset to factory default setting.
1) The current of one of the color group LEDs is too strong or too weak.
2) LED brightness not enough
Partial color
partial red,partial green, partial blue or partial white
2010.1.152010.1.15
Page 4
1.3 TECHNICAL SPECIFICATIONS
LED MODULE
Dimensions
LED MODULE:
Voltage
Rated Power
IP67 protection rating 48pcs (12 x RED / 12 x GREEN / 12 x BLUE/ 12 x WHITE)
Weight
LED/Unit
Output/LED
Cooling
IP
3W
Direct air convection
305 x 276 x 230mm
8.5Kg
100~250V...50/60Hz
180W
1 PRODUCT(GENERAL)
2
Environment Temperature
-20 ~40
305mm
276mm
230mm
115mm
13mm
8.5mm
204mm
4.3 BASIC INSTRUCTIONS FOR DMX512 OPERATION (STAGE1)
MASTER DIMMER
CH1 controls the intensity of the currently projected color When the slider is at the highest position (255) the intensity of the output is
the maximum
RED, GREEN & BLUE & WHITE COLOR SELECTION
CH2, CH3 & CH4 & CH5 control the intensity ratio of each of the RED,
GREEN, BLUE & WHITE LEDs.
When the slider is at the highest position (255) the intensity of the color is
the maximum.
CH2, CH3, CH4 & CH5 can be combined together to create over 16 million
colors.
COLOR MACROS
CH6 selects the required COLOR MACRO CH6 has priority over CH2, CH3, CH4 & CH5 CH1 is used to control the intensity of the COLOR MACRO
STROBE
CH 7 controls the strobe of CH1 to CH6 Strobe 1 is with RGB in-step Strobe 2 is with RGB out-step Strobe 3 is a pulse strobe(fast on/slow off) Strobe 4 is a pulse strobe (slow on/fast off) CH7 has priority over CH2, CH3, CH4 &CH5.
ID ADDRESS SELECTION
CH9 is used to select the target ID address. Each independent DMX address may have upto 66 independent ID
addresses.
An ID address of 0 will activate all ID address locations.
AUTO
CH8 selects the preset AUTO programs AT.01-AT.10 or the custom AUTO
programs CUS.01-CUS.10
When activating the custom AUTO programs CUS.01 to CUS.10 then it is possible to control the STEP TIME and FADE TIME using CH2 and CH3 respectively.
CH8 has priority over CH2, CH3, CH4, CH5, CH6 & CH7.
DIMMER SPEED
CH10 is for selecting the dimmer mode and dimmer speed. When DIMMER is set to Off , then RGBW and MASTER DIMMER are linear. The Dim 1/2/3/4 are different speed of the non linear dimmer .
19
4 USING A DMX512 CONTROLLER 2010.1.152010.1.15
Page 5
1.4 PHOTOMETRIC DATA
PHOTOMETRIC DATA
1 PRODUCT(GENERAL)
3
RED
1 2 3
0
1
2
3
3931
1010 482 274 186 LUX
15
GREEN
1 2 3
0
1
2
3
6130
1700 776 450 304 LUX
15
BLUE
1 2 3
0
1
2
3
1360
256 120 68 46 LUX
15
WHITE
1 2 3
0
1
2
3
2
4
6 8
10Distance(m)
4613
1204 552 326 230 LUX
15
RGB
1 2 3
0
1
2
3
2
4
6 8
10Distance(m)
11340
2885 1285 765 530 LUX
15
1 2 3
0
1
2
3
2
4
6 8
10Distance(m)
16300
4000 1900 1122 752 LUX
15
RGB+WHITE
2
4
6 8
10Distance(m)
2
4
6 8
10Distance(m)
2
4
6 8
10Distance(m)
Ar2.s
18
4 USING A DMX512 CONTROLLER
1
2
0 255
CHANNEL FUNCTIONVALUE
3
0 255
0 255
HSV
1
2
0 255
CHANNEL FUNCTIONVALUE
3
0 255
0 255
VALUE(0~100%)
SATURATION(0~100%)
HUE(0~100%)
4
5
6
0
0
0
255
255
255
BLUE
GREEN
RED
WHITE
MASTER DIMMER
STROBE
2010.1.152010.1.15
Page 6
1.5 SAFETY WARNING
IMPORTANT
ALWAYS READ THE USER MANUAL BEFORE OPERATION.
PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA.
This product must be installed by a qualified professional. Always operate the equipment as described in the user manual. A minimum distance of 0.5m must be maintained between the equipment
and combustible surface.
The product must always be placed in a well ventilated area. Always make sure that the equipment is installed securely. DO NOT stand close to the equipment and stare directly into the LED
light source.
Always disconnect the power supply before attempting and maintenance. Always make sure that the supporting structure is solid and can support
the combined weight of the products.
The earth wire must always be connected to the ground. Do not touch the power cables if your hands are wet.
ATTENTION
This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual.
Avoid shaking or strong impacts to any part of the equipment.
Make sure that all parts of the equipment are kept clean and free of dust.
Always make sure that the power connections are connected correct and secure.
If there is any malfunction of the equipment, contact your distributor immediately.
When transferring the product, it is advisable to use the original packaging in which the product left the factory.
Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired.
The lamp (LED) shall be changed if it has become damaged or thermally deformed.
1 PRODUCT(GENERAL)
4 17
4 USING A DMX512 CONTROLLER
Ar1.d
BLUE
1
2
0 255
CHANNEL FUNCTIONVALUE
3
4
0 255
0 255
0 255
GREEN
RED
MASTER DIMMER
Arc.2
BLUE
1
2
0 255
CHANNEL FUNCTIONVALUE
3
4
0 255
0 255
0 255
GREEN
RED
WHITE
Ar2.d
BLUE
1
2
0 255
CHANNEL FUNCTIONVALUE
3
4
0 255
0 255
0 255
GREEN
RED
WHITE
5
0 255
MASTER DIMMER
2010.1.152010.1.15
Page 7
2.1 MOUNTING
HANGING
UPRIGHT
The fixture can be mounted in an upright or sitting position using the supporting brackets.
The fixture can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cable should also be used.
@ 220V: 10 units may be connected in series @120V: 5 units may be connected in series
The LED MODULE can be mounted at any angle and in any position. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture.
2.2 POWER CONNECTIONS
5
2 INSTALLATION
Note:
1. As this fixture's DMX signal cable connection is Parallel connection, so if over 32 units to be connected, then a DMX signal amplifier is needed.
2. If the signal cable is over 60m between the DMX512 controller and fixture or beween two fixtures, then a DMX signal amplifier is needed as well.
2 INST ALLA TION
16
4 USING A DMX512 CONTROLLER
ID21 ID22
210 211
11
ID20
200 209
ID19
190 199
ID18
180 189
ID14 ID15 ID16 ID17
140 149 150 159 160 169 170 179
ID65 ID66
254 255
ID8 ID9 ID10 ID11 ID12 ID13
80 89
90 99 100 109 110 119 120 129 130 139
CHANNEL FUNCTIONVALUE
ID6 ID7
60 69
70 79
Arc.1
BLUE
1
2
0 255
CHANNEL FUNCTIONVALUE
3
0 255
0 255
GREEN
RED
2010.1.152010.1.15
Page 8
2.3 SETTING UP WITH A DMX512 CONTROLLER
2.3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING (TOUR MODE)
The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1, with the sec o nd set at 12 and so on... (Note that when used i n this way, the CH11 ID function must be inactive (CH11=0))
DMX512 CONTROLLER
Connect the DMX512 controller to the units in series. Each unit has 11 DMX channels so the DMX Addresses should increase by increments of
11 (e.g. 1,12,23,34...)
The ID address has not been set so therefore when using the controller CH11 must
be inactive ( CH11=0 ).
It is also possible to deactivate ID address selecting ID OFF from the Settings menu.
on the fixture
Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used.
2.3-2 DMX512 ADDRESSING WITH ID ADDRESS (TOUR MODE)
Connect the DMX512 controller to the units in series Each unit has 11 DMX channels so the DMX Addresses should increase by increments of
11 (e.g. 1,12,23,34...)
Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used. Each DMX address may carry up to 66 separate ID addresses. ID should be set in the menu on each unit in ascending values
(i.e. 1,2,3...)
ID On should be set in the Settings menu on each unit. ID addresses are accessible from Ch9 on the DMX512 controller.
Example:
6
2 INSTALLATION
............
DMX Addr.1 DMX Addr.12 DMX Addr.23
15
4 USING A DMX512 CONTROLLER
CHANNEL FUNCTIONVALUE
7
8
0 10
1~20Hz
11
255
CUSTOM 2 CUSTOM 3 CUSTOM 4 CUSTOM 5 CUSTOM 6 CUSTOM 7 CUSTOM 8 CUSTOM 9 CUSTOM 10
121 130 131 140 141 150 151
160
161
170
171
180
181
190
191
200
201 210
CUSTOM 1
211 220 221 255
71
80
81
90
91
100
101 110
AUTO 6 AUTO 7 AUTO 8 AUTO 9
111 120
AUTO 10
0 20 21 30 31 40 41 50 51
60
61
70
AUTO 1
AUTO 2 AUTO 3 AUTO 4 AUTO 5
0 255
9
231 235 236 240 241 245 246 250 251 255
WHITE 7: 6500K WHITE 8: 7200K WHITE 9: 8000K WHITE 10: 8500K
WHITE 11: 10000K
6
DIMMER SPEED
LINEAR DIMMER NON LINEAR DIMMER 1 fastest
10 29 30 69 70 129
130 189 190 255
10
NON LINEAR DIMMER 2 NON LINEAR DIMMER 3 NON LINEAR DIMMER 4 slowest
ID1~ID66 ID1 ID2 ID3 ID4 ID5
0 9 10 19 20 29 30 39 40 49 50 59
11
NO FUNCTION
AUTO
NO FUNCTION
STROBE
NO FUNCTION
ID ADDRESS
AUTO SPEED ADJUSTMENT
When using CH8,AUTO01-AUTO10, this function ac tivated
0 9
PRESET DIMMER SPEED FROM DISPLAY MENU
2010.1.152010.1.15
Page 9
DMX512 CONTROLLER
Example:
The figure above shows a simple DMX layout which has used three units at each DMX address. The three units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting CH11 to 0, or to control each unit independently by first selecting the DMX address and then by using CH11 to locate the target ID address.
7
2 INSTALLATION
............
DMX Addr.1 ID Addr.1
DMX Addr.1 ID Addr.2
DMX Addr.1 ID Addr.3
DMX Addr.12 ID Addr.1
DMX Addr.12 ID Addr.2
DMX Addr.12 ID Addr.3
Note: This product have three DMX512 channel configuration: TOUR ,
Arc.1 , Ar1.d , Arc.2 , Ar2.d , Ar2.s and HSV
4.1 BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable or
the IP65 rated cable provided.
Set the DMX512 address in the DMX menu. It is possible to have the same DMX address or independent addresses for
each fixture.
4.2 CHANNEL ASSIGNMENT
14
4 USING A DMX512 CONTROLLER
TOUR
4 USING A DMX512 CONTROLLER
1
2
0 255
3
4
0 255
0 255
0 255
5
0 255
0 5
6 21 31 51 71 91
111
20 30 50 70 90 110
130 131 150 151 170 171 190 191 200 201 205 206 210 211 215 216 220 221 225 226 230
HIGH POWER(only when in NORMAL POWER mode)
RED 0%/GREEN100%/BLUE UP RED 0%/GREENDOWN/BLUE 100% RED UP/GREEN 0%/BLUE 100% RED 100%/GREEN 0%/BLUE DOWN RED 100%/GREEN UP/BLUE UP RED DOWN/GREEN DOWN/BLUE 100%
WHITE 1: 3200K
RED 100%/GREEN 100%/BLUE 100%/WHITE 100%
RED 100%/GREEN UP/BLUE 0% RED DOWN/GREEN 100%/BLUE 0%
WHITE 2: 3400K WHITE 3: 4200K WHITE 4: 4900K WHITE 5: 5600K WHITE 6: 5900K
6
COLOR MACRO
CHANNEL FUNCTIONVALUE
BLUE
WHITE
GREEN (or FADE TIME when CUS.01-CUS.10 in CH8 is activated)
RED
(or STEP TIME when CUS.01-CUS.10 in CH8 is activated)
MASTER DIMMER
NO FUNCTION
NO FUNCTION
2010.1.152010.1.15
Page 10
3.1 BASIC
enter the currently selected menu or confirm the current function value scroll 'UP' through the menu list or increase the value of the current function scroll 'DOWN' through the menu list or decrease the value of the current function
scroll through the main menu or return to the main menu
3 DISPLAY PANEL OPERATION
MENU
3 DISPLAY PANEL OPERATION
8
ENTER UP
DOWN
MENU
ENTER
CAL2 Enter the CAL2 to adjust the RGB parameter to make different whites.
CAL2
When the new setting is activated, the DMX controller choose RGB = 255,255, 255, the white color will be made by the actual RGB values on the .
3.12 WHITE BALANCE
13
3 DISPLAY PANEL OPERATION
WT01 WT02
WT11
Red Green Blue White
(0~255) (0~255) (0~255) (0~255)
CAL1
MENU
CAL1
Enter the CAL1 to select white color of different color temperature. There are 11 pre-programmed White colors can be edited by using Red ,
Green , Blue & White .
3.1 1 WHITES SETTING
RGBW
Red Green Blue
(0~255) (0~255) (0~255)
CAL2
MENU
KEY ON
OFF
MENU
3.13 A CTIVATE THE PASSWORD
KEY
Enter the KEY mode to select whether the access password is on or off.
When the fixture is set as PASS ON , after 30 seconds or turn on the fixture next time, the fixture will need an access password to enter the display menu control.
Note: The factory access password is UP + DOWN + UP + DOWN , then press ENTER to confirm the access.
2010.1.152010.1.15
Page 11
3.2 MENU
3 DISPLAY PANEL OPERATION
9
PR.01 PR.02
PR.10
RUN DMX
SLAV
SC.01 SC.02
SC.30
AT.01 AT.02
AT.10
AUTO
PR.01 PR.02
PR.10
D(001~512)
DMX
ID
ID(01~66)
Red Green Blue White Strobe Time Fade
(0~255) (0~255) (0~255) (0~255) (0~20) (0~255) (0~255)
SET
UPLD
ID
POW
ON OFF
NORM
HIGH
KEY ON
OFF
TOUR Arc.1
Arc.2
Ar1.d
Ar2.s
Ar2.d
WT01 WT02
WT11
Red Green Blue White
(0~255) (0~255) (0~255) (0~255)
MENU
Red Green Blue White
(0~255) (0~255) (0~255) (0~255)
Strob
(0~20)
STAT
PERS
EDIT
REST
ON OFF
RGBW
CAL1
RGBW
Red Green Blue
(0~255) (0~255) (0~255)
CAL2
HSV
Off Dim1
Dim3
Dim2
Dim4
Dim
12
3 DISPLAY PANEL OPERATION
PR.01 PR.02
PR.10
SC.01 SC.02
SC.30
Red Green Blue White Strobe Time Fade
(0~255) (0~255) (0~255) (0~255) (0~20) (0~255) (0~255)
EDIT
MENU
3.9 EDITING CUSTOM PROGRAMS
EDIT CUSTOM
Enter the EDIT mode to edit the custom programs PR.01 to
PR.10 .
Each custom program has 30 steps that can be edited. Each step allows the creation of a scene using RED Red , GREEN Green , BLUE
Blue , WHITE White , STROBE Strobe , TIME Time & FADE Fade .
SET
UPLD
ID
POW
ON OFF
NORM
HIGH
REST
ON OFF
RGBW
Off Dim1
Dim3
Dim2
Dim4
Dim
MENU
3.10 SPECIAL SETTINGS
SETTING
Select UPLD to upload the custom programs from the current MASTER unit to
the SLAVE units.
In order to activate the upload function the password must be entered. Password is the same as the main access password. When uploading the MASTER and SLAVE units will display YELLOW. If an error occurs when uploading the MASTER and/or SLAVE units will display RED. On successful uploading of the custom programs the MASTER and SLAVE units
will display GREEN.
In order to reset custom modes to default values select REST . Enter ID in order to allow/disallow ID address function from the DMX512
controller.
When RGBW -- RGB TO WHITE is set to YES , on RGB = 255,255,255, the color is perfect white as the actual RGB values are adjusted to make white. When it is set to NO ,on RGB = 255,255,255, the RGB values are not adjusted and the output is most powerful. The RGB W s parameter can be adjusted in CAL2 .
Enter POW to choose the operation power mode NORM or HIGH , when it is normal mode, the power consumption is about 90W, while under high mode, it is about 150W.
Enter Dim to select dimmer mode and dimmer speed. When DIMMER is set to Off , then RGBW and MASTER DIMMER are linear. The Dim 1/2/3/4 are speed modes of the non linear dimmer , Dim1 is the faster, while Dim4 is the slowest. The factory default setting is Dim4 .
2010.1.152010.1.15
Page 12
3.3 EDIT STATIC COLOUR
3.4 ACTIVATING AUTO PROGRAMS
AUTO
Select the target AUTO program and press ENTER . Programs AT.0 1 to AT.10 are fully pre-programmed and will not be altered
by changes in EDIT mode.
Programs PR.01 to PR.10 are fully pre-programmed and can be edited
in EDIT mode.
STATIC COLOUR
Combine Red , Green , Blue and White to create an infinite range
of colors (0-255)
Set the value of the Strobe (0-20Hz)
MENU
Red Green Blue White
(0~255) (0~255) (0~255) (0~255)
Strob
(0~20)
STAT
AT.01 AT.02
AT.10
AUTO
PR.01 PR.02
PR.10
MENU
RUN Enter the RUN mode to set working mode.
DMX mode is for using the DMX512 controller to control the fixtures. SLAV mode is for Master -- Slave operation.
3.5 RUN MODE
RUN DMX
SLAV
MENU
3.6 DMX512 SETTINGS
DMX Enter the DMX mode to set the DMX ADDRESS.
3.7 PERSONALITY
PERSONALITY Enter the PERSONALITY mode to select DMX mode: TOUR , Arc.1 ,
Ar1.d , Arc.2 , Ar2.d , Ar2.s or HSV .
3.8 ID ADDRESS
ID Enter the ID mode to set the ID ADDRESS.
D(001~512)
DMX
MENU
TOUR Arc.1
Arc.2
Ar1.d
Ar2.s
Ar2.d
PERS
HSV
MENU
ID
ID(01~66)
MENU
11
3 DISPLAY PANEL OPERATION
10
3 DISPLAY PANEL OPERATION
2010.1.152010.1.15
Loading...