7Plug and connection assignment.................................................................................................... 24
8Protecting the environment.............................................................................................................. 25
SDC-24 DMX Desk
DMX controller
3
Page 4
SDC-24 DMX Desk
4
DMX controller
Page 5
1 General information
This manual contains important instructions for the safe operation of the unit. Read and follow
the safety instructions and all other instructions. Keep the manual for future reference. Make
sure that it is available to all those using the device. If you sell the unit please make sure that
the buyer also receives this manual.
Our products are subject to a process of continuous development. Thus, they are subject to
change.
General information
SDC-24 DMX Desk
DMX controller
5
Page 6
General information
1.1 Further information
On our website (www.thomann.de) you will nd lots of further information and details on the
following points:
DownloadThis manual is also available as PDF le for you to download.
SDC-24 DMX Desk
6
DMX controller
Keyword search
Online guides
Personal consultation For personal consultation please contact our technical hotline.
Service
Use the search function in the electronic version to nd the topics of
interest for you quickly.
Our online guides provide detailed information on technical basics
and terms.
If you have any problems with the device the customer service will
gladly assist you.
Page 7
1.2 Notational conventions
This manual uses the following notational conventions:
General information
Letterings
The letterings for connectors and controls are marked by square brackets and italics.
Examples: [VOLUME] control, [Mono] button.
1.3 Symbols and signal words
In this section you will nd an overview of the meaning of symbols and signal words that are
used in this manual.
SDC-24 DMX Desk
DMX controller
7
Page 8
General information
Signal wordMeaning
DANGER!This combination of symbol and signal word indicates an
immediate dangerous situation that will result in death or
serious injury if it is not avoided.
NOTICE!This combination of symbol and signal word indicates a pos‐
sible dangerous situation that can result in material and
environmental damage if it is not avoided.
Warning signsType of danger
Warning – danger zone.
SDC-24 DMX Desk
8
DMX controller
Page 9
2 Safety instructions
Safety instructions
Intended use
This device is used to control spotlights, dimmers, lighting eects equipment or other DMXcontrolled devices. Use the device only as described in this user manual. Any other use or use
under other operating conditions is considered to be improper and may result in personal
injury or property damage. No liability will be assumed for damages resulting from improper
use.
This device may be used only by persons with sucient physical, sensorial, and intellectual
abilities and having corresponding knowledge and experience. Other persons may use this
device only if they are supervised or instructed by a person who is responsible for their safety.
SDC-24 DMX Desk
DMX controller
9
Page 10
Safety instructions
Safety
DANGER!
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not
within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from
the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.
NOTICE!
Risk of re
Do not block areas of ventilation. Do not install the device near any direct heat
source. Keep the device away from naked ames.
SDC-24 DMX Desk
10
DMX controller
Page 11
Safety instructions
NOTICE!
Operating conditions
This device has been designed for indoor use only. To prevent damage, never
expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and
strong vibrations.
Only operate the device within the ambient conditions specied in the chapter
‘Technical specications’ of this user manual. Avoid heavy temperature uctua‐tions and do not switch the device on immediately after it was exposed to tem‐
perature uctuations (for example after transport at low outside temperatures).
Dust and dirt inside can damage the unit. When operated in harmful ambient
conditions (dust, smoke, nicotine, fog, etc.), the unit should be maintained by
qualied service personnel at regular intervals to prevent overheating and other
malfunction.
SDC-24 DMX Desk
DMX controller
11
Page 12
Safety instructions
NOTICE!
Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches
the voltage rating of the device and that the AC outlet is protected by a residual
current circuit breaker. Failure to do so could result in damage to the device and
possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long
periods of time to reduce the risk of electric shock or re.
NOTICE!
Possible staining
The plasticiser contained in the rubber feet of this product may possibly react
with the coating of your parquet, linoleum, laminate or PVC oor and after some
time cause permanent dark stains.
In case of doubt, do not put the rubber feet directly on the oor, but use felt-pad
oor protectors or a carpet.
SDC-24 DMX Desk
12
DMX controller
Page 13
Safety instructions
NOTICE!
Possible damage due to installation of a wrong fuse
The use of dierent types of fuses can cause serious damage to the unit. Fire
hazard!
Only fuses of the same type may be used.
SDC-24 DMX Desk
DMX controller
13
Page 14
Features
3 Features
Special features of the device:
n 24 channel faders
n 2 displays to display channel values
n Start address selectable via DIP switches
n Linking of up to 4 desks to control up to 96 channels
n Simple operation
n Ideal for testing DMX devices or simple applications
n 16 coloured fader caps included
SDC-24 DMX Desk
14
DMX controller
Page 15
4 Starting up
Starting up
Unpack and carefully check that there is no transportation damage before using the unit. Keep
the equipment packaging. To fully protect the device against vibration, dust and moisture
during transportation or storage use the original packaging or your own packaging material
suitable for transport or storage, respectively.
Create all connections while the device is o. Use the shortest possible high-quality cables for
all connections. Take care when running the cables to prevent tripping hazards.
NOTICE!
Possible data transmission errors
For error-free operation make use of dedicated DMX cables and do not use ordi‐
nary microphone cables.
Never connect the DMX input or output to audio devices such as mixers or ampli‐
ers.
SDC-24 DMX Desk
DMX controller
15
Page 16
Starting up
Connections in DMX mode
Connect the DMX input of the device to the DMX output of a DMX controller or another DMX
device. Connect the output of the rst DMX device to the input of the second one, and so on
to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain
is terminated with a resistor (110 Ω, ¼ W).
SDC-24 DMX Desk
16
DMX controller
Page 17
5 Connections and controls
Front panel
Connections and controls
SDC-24 DMX Desk
DMX controller
17
Page 18
Connections and controls
1 Channel faders [1] … [24]
Individual control of up to 24 DMX channels
2 [CH]
Display of the values set with the faders
3 [DMX]
Display of assigned DMX channels
SDC-24 DMX Desk
18
DMX controller
Page 19
Rear panel
Connections and controls
SDC-24 DMX Desk
DMX controller
19
Page 20
Connections and controls
4 DIP switch for setting the DMX address
0: DIP switch is in ‘[OFF]’ position. 1: DIP switch is in ‘[ON]’ position.
The value of the DIP switches 1-9 is binary coded. DIP switch 10 is without function. To set the desired DMX address, set
the DIP switches so that the sum of the resulting numbers yields the desired DMX address. Please orient yourself by the
following table:
123456789DMX address
1000000001
0100000002
0010000004
0001000008
00001000016
00000100032
00000010064
000000010128
SDC-24 DMX Desk
20
DMX controller
000000001256
Page 21
Connections and controls
5 [DMX OUT]
DMX output
6 DMX input [DMX IN]
An additional DMX controller can be connected via [DMX IN] to control more than 24 channels. Up to four controllers can
be linked to control up to 96 channels. When the rst device outputs the addresses [1] … [24] and a second device out‐
puts the addresses [25] … [48], for example, the signal is executed without change. If the DMX ranges of both controllers
overlap, e.g. both controllers are set to channels [1] … [24], the last changed setting of the controller is output.
7 [ON | OFF]
Main switch. Turns the device on and o.
8 IEC chassis plug for mains connection, with fuse holder
This chapter will help you select the right cables and plugs to connect your valuable equip‐
ment so that a perfect light experience is guaranteed.
Please take our tips, because especially in ‘Sound & Light’ caution is indicated: Even if a plug
ts into a socket, the result of an incorrect connection may be a destroyed DMX controller, a
short circuit or ‘just’ a not working light show!
The unit oers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please
refer to the drawing and table below for the pin assignment of a suitable XLR plug.
PinConguration
1Ground, shielding
2Signal inverted (DMX–, ‘cold signal’)
3Signal (DMX+, ‘hot signal’)
SDC-24 DMX Desk
24
DMX controller
Page 25
8 Protecting the environment
Disposal of the packaging mate‐
rial
For the transport and protective packaging, environmentally friendly materials have been
chosen that can be supplied to normal recycling.
Ensure that plastic bags, packaging, etc. are properly disposed of.
Do not just dispose of these materials with your normal household waste, but make sure that
they are collected for recycling. Please follow the notes and markings on the packaging.
Disposal of your old device
This product is subject to the European Waste Electrical and Electronic Equipment Directive
(WEEE) in its currently valid version. Do not dispose with your normal household waste.
Dispose of this device through an approved waste disposal rm or through your local waste
facility. When discarding the device, comply with the rules and regulations that apply in your
country. If in doubt, consult your local waste disposal facility.