Thinklogical VTM-004200, VTM-Q04200 Product Manual

thinklogical®
T-Series Chassis & Modules
®
Website: www.thinklogical.com Facebook: www.facebook.com/ThinklogicalUSA LinkedIn: www.linkedin.com/company/thinklogical Google+: http://plus.google.com/u/0/109273605590791763795/about YouTube: www.youtube.com/user/thinklogicalNA Twitter: @thinklogical
Copyright Notice
Copyright © 2016. All rights reserved. Printed in the U.S.A.
Thinklogical, LLC® 100 Washington Street Milford, Connecticut 06460 U.S.A. Telephone: 1-203-647-8700
All trademarks and service marks are property of their respective owners.
Subject: VelocityKVM T-Series DVI Modules Product Manual Revision: G, October 2016
thinklogical®
T-Series DVI Modules, Rev. G 2 October, 2016
thinklogical®
Table of Contents
PREFACE ...................................................................................................................................................................... 4
Conventions Used in this Manual ............................................................................................................................... 4
1. SYSTEM FEATURES ................................................................................................................................................ 5
1.1 T-Series DVI Modules ....................................................................................................................................... 5
1.2 Contents ............................................................................................................................................................ 6
1.2.1 Video Cables ............................................................................................................................................... 6
1.2.2 Peripheral cables ........................................................................................................................................ 6
2. CONNECTING VelocityKVM T-SERIES EXTENDERS ............................................................................................ 7
2.1 Transmitter Modules ....................................................................................................................................... 7
2.2 Receiver Modules............................................................................................................................................. 7
2.3 Module LEDs .................................................................................................................................................... 8
2.4 Fiber Optic Cables ........................................................................................................................................... 8
2.5 Installation ........................................................................................................................................................ 8
Rear Panel Views ................................ ................................................................ ............................................. 9
2.6 Set-Up ............................................................................................................................................................... 9
Dry Contact Alarm ........................................................................................................................................... 9
Firmware Upgrades ......................................................................................................................................... 9
2.7 T-Series Application Diagrams ..................................................................................................................... 10
2.7.1 VTM Transmitters to VelocityKVM Receivers (through 2 VX160 Routers) ...................................... 10
2.7.2 VelocityKVM Transmitters to VTM Receivers (through a VX160 Router) ........................................ 10
2.7.3 Dual-Link DVI: VTM-8 Transmitters to VTM-8 Receivers (through 2 VX160 Routers) ..................... 11
2.7.4 T-Series Transceiver Configuration (through a VX160 Router) ........................................................ 11
2.8 Technical Specifications ................................................................................................................................ 12
2.9 Velocity Unbalanced Audio Specifications ................................................................................................... 13
3. REGULATORY & SAFETY COMPLIANCE ............................................................................................................ 13
3.1 Safety Requirements ...................................................................................................................................... 13
Symbols Found on the Product ...................................................................................................................... 13
Regulatory Compliance .................................................................................................................................... 13
North America ................................................................................................................................................... 13
Australia & New Zealand .................................................................................................................................. 14
European Union ................................ ................................................................ ................................ ................ 14
Declaration of Conformity .......................................................................................................................... 14
Standards with Which Our Products Comply ................................................................................................ 14
3.2 Supplementary Information ........................................................................................................................... 14
Product Serial Number ..................................................................................................................................... 15
Connection to the Product ............................................................................................................................... 15
4. HOW TO CONTACT US .......................................................................................................................................... 15
4.1 Customer Support .......................................................................................................................................... 15
Website .............................................................................................................................................................. 16
Email .................................................................................................................................................................. 16
Telephone .......................................................................................................................................................... 16
Fax ..................................................................................................................................................................... 16
4.2 Product Support ............................................................................................................................................. 16
Warranty ........................................................................................................................................................... 17
Return Authorization ........................................................................................................................................ 17
Our Addresses ................................................................................................................................................. 17
APPENDIX A: Quick Start Guides ............................................................................................................................. 18
A.1 VTM-24 Transmitters to VTM-24 Receivers (direct)................................................................................... 18
A.2 VTM-4/VTM-24 Tx to VTM-4/VTM-24 Rx (through VX80 Router) ............................................................... 19
A.3 VTM-4/VTM-8 Tx to Vel-4/Vel-8 Rx (through VX40 Router) ....................................................................... 20
APPENDIX B: Thinklogical KVM Extenders- Theory of Operation ........................................................................ 21
APPENDIX C: VelocityKVM T-Series Standard Model Ordering Information ........................................................ 22
APPENDIX D: VelocityKVM T-Series Multi-Path and Separate-Path Model Ordering Information ..................... 23
T-Series DVI Modules, Rev. G 3 October, 2016
thinklogical®
BEFORE STARTING ANY PROCEDURE, IT IS RECOMMENDED
THAT YOU READ THE INSTRUCTIONS THOROUGHLY!
PREFACE
Conventions Used in this Manual
Throughout this manual you will notice certain symbols that bring your attention to important information. These are Notes and Warnings. Examples are shown below.
Note: Important Notes appear in blue text preceded by a yellow exclamation point symbol, as shown here.
A note is meant to call the reader’s attention to helpful information at a point in the text that is relevant to the subject being discussed.
Warning! All Warnings appear in red text, followed by blue text, and preceded by a red
stop sign, as shown here.
A warning is meant to call the reader’s attention to critical information at a point in the text that is relevant to the subject being discussed.
The VelocityKVM T-Series VTM-24 Transmitter Module: VTM-U00024-LCTX
T-Series DVI Modules, Rev. G 4 October, 2016
thinklogical®
1. T-Series DVI Modules
The Logical Solution: Modular KVM Extension/DVI and SDI Support in One Unit
The VelocityKVM line of extenders continues to evolve and add value with exciting new capabilities. The VelocityKVM T-4200 is housed in a high reliability, rack-space-saving chassis that includes all of the same capabilities in a 1U device that used to require 2U. Featuring a dual interface and current sharing power supplies, each 1U chassis supports two separate interface modules, allowing users to combine module options within one chassis.
Each T-Series module (VTM- prefix) is also available in a Desktop version (VDM- prefix) that fits into our Velocity Desktop Chassis, which features a single power supply housed in a 1U chassis designed to accommodate any one module from our Desktop line.
Available modules support a variety of video display options and all modules support PS2, full duplex
stereo audio (unbalanced), stereo emitter, serial (RS-232), USB 2.0 (up to 480 Mbps) and/or USB 1.0 HID. Modules that support Multi Video Paths, Separate Audio Paths and Separate Data Paths are
also available. (See Appendixes C and D on pages 22 and 23.) Using multi-mode or single-mode fiber, the system allows users to securely locate a display device and
peripherals up to 40 kilometers away from the controlling computer without loss of resolution. In addition, all high speed peripherals function with no latency, making it ideally suited for a wide range
of applications in the broadcast and post-production field, command and control centers, universities, air traffic control, energy production and exploration, and most other commercial KVM applications.
1.1 T-Series Module Features
T-Series DVI Modules, Rev. G 5 October, 2016
thinklogical®
VelocityKVM Desktop
Modular Chassis
VED-000001
DVI Male DVI Male
2 each – 6 pin mini din (6’) 2 each – USB A-B (6’) 2 each – 3.5mm to 3.5mm plug (6’) 1 each – DB9M to DB9F (6’) 1 each – BNC male to male, 50 Ω (6’)
1.2 Contents
When you receive your Thinklogical® VelocityKVM T-Series or Desktop Series Extender System, you should find the following items:
VelocityKVM T-4200 Modular Chassis w/ dual Power Supply Modules
-OR-
VelocityKVM Desktop Modular Chassis w/ single Power Supply Module
VelocityKVM T-Series or Desktop Extender Module(s): Transmitter/Receiver/Transceiver AC power cord(s), PWR-000006-R (International connections may differ) – Qty 1 or 2 VelocityKVM Extender Cables:
Video Cable, 2 Meters – See Technical Specifications, pg. 12
Audio Cable Kit (8 pcs., para. 1.2.2 below), 6 Feet, KIT-000005-R – Qty 1 VelocityKVM T-4200 or Desktop Extender Product Manual CD Product Quick Start Guide
Video Cables
Single-link: DVI-D Male Cable, 2 Meters (CBL000009-002MR)
Peripheral Cables
KIT-000005-R Audio Cable Kit (8 pcs.)– Qty 1
T-Series DVI Modules, Rev. G 6 October, 2016
thinklogical®
USB 2.0 Port
Control Download
Device Download
PS2 Kybd. from CPU USB HID Port
PS2 Mouse from CPU
RS-232 Serial Port (F)
Audio IN
Audio OUT
3D Stereo IN
DVI Video 2
IN
DVI Video 1
IN
L1: Video 1 & Data Tx to Rx
L2: Data Rx to Tx
L3: Video 2
VTM-24 Multi-Mode Transmitter
Fiber Optic Ports
Fiber Connection/
Alarm LEDs
USB 2.0 Link/Host Indicator LEDs
Host Download
PS2 to Keyboard USB HID Ports (4)
Audio IN
DVI Video 2
OUT
DVI Video 1
OUT
L1: Video 1 & Data Tx to Rx
L2: Data Rx to Tx
L3: Video 2
3D Stereo
OUT
USB 2.0 Ports (4)
Control Download
PS2 to Mouse
RS-232 Serial Port (M)
Audio OUT
VTM-24 Multi-Mode Receiver
Fiber Optic Ports
Fiber Connection/
Alarm LEDs
USB 2.0 Link/Device Indicator LEDs
2. Connecting VelocityKVM T-Series Extenders
All physical connections to the product use industry-standard connectors. Non-supplied cables are commercially available. All connections are found on the rear of the unit.
2.1 Transmitter Modules
The Transmitter Module connects to the CPU (or other sources) using the supplied cables listed above. The Transmitter then connects to the Receiver via multi-mode or single-mode fiber-optic cables. (See paragraph 2.8 Technical Specifications on page 12, for details about specific optical distances using various fiber types.)
2.2 Receiver Modules
The Receiver Module receives video and KVM data from the Transmitter via multi-mode or single-mode fiber-optic cables. The Receiver’s output ports connect to the destination peripheral devices with their own standard cables.
T-Series DVI Modules, Rev. G 7 October, 2016
thinklogical®
Standard multi-mode fiber optic cable (up to 1000 meters),
50 or 62.5 microns, terminated with LC-type connectors
Transmit◄Receive
2.3 Module LEDs
Both the Transmitter and Receiver Modules feature five LEDs. Their functions are as follows:
2.4 Fiber Optic Cable
Fiber optic cables connect the Transmitters to the Receivers. Standard multi-mode fiber optic cables must be 50 or 62.5 microns, terminated with LC type fiber optic connectors. Be careful not to kink or
pinch the fiber optic cable as it is being installed and keep all bend diameters to no less than 3 inches (76.2mm).
With two fibers connected (in models with one SFP) or with three fibers connected (in models with two SFPs) video information is transmitted from the TX to the RX over fiber L1 (and L3 in models with two SFPs). Fiber L2 is used as a data return path from the RX to the TX, allowing full duplex, bi-directional RS-232 data transfer.
2.5 Installation
All physical connections to the product use industry-standard connectors. Non-supplied cables are commercially available. All connections are found on the rear of the unit.
T-Series DVI Modules, Rev. G 8 October, 2016
Rear Panel Views
T-4200 as a Transciever (Single-Link, 1 DVI Display)
VTM-4 Tx
VTM-4 Rx
T-4200 as 2 Receivers (Dual-Link DVI & Single-Link RGB Displays)
VTM-5 RxVTM-8 Rx
VTM-24 Tx
VTM-24 Rx
T-4200 as a Transceiver (Single-Link, 2 DVI Displays)
T-4200 as 2 Transmitters (Dual-Link DVI & Single-Link RGB Displays)
VTM-5 TxVTM-8 Tx
NORMALLY CLOSED NORMALLY OPEN
COMMON
ALARM
thinklogical®
A selection of Velocity T-4200 Rear Panels in Transceiver, Receiver & Transmitter Configurations
2.6 Set-Up
Dry Contact Alarm
Dry contact alarms are located on the transmitter and receiver units. When there is an alarm condition the relay is energized. An example of possible alarm causes might be over-temperature or a power supply issue.
Firmware Upgrades
Firmware upgrades are available through Thinklogical. Please call 1-203-647-8700 for assistance.
The dry contact alarm is a Form C contact with the following ratings:
Nominal Switching Capacity: 1 A 30 VDC Max. Switching Power: 30 W DC
.