Thetford 19617 User Manual

Water Connection Fitting
RV Toilet Service Parts
for Aria/Aria Deluxe
Tools needed
Flat-blade screwdriver
Adjustable Wrench (if removing Toilet from floor)
Notes:
If there is enough clearance behind toilet, this proce­dure may be able to be done without removing toilet from floor.
“Clockwise” and “counterclockwise” are as viewed from above toilet.
There are two possible versions of this part (Fig. A).
If Necessary To Remove Toilet From Floor
1. Turn off RV water supply per RV Owners Manual.
2. Press both keypad buttons at the same time, twice, to open blade and drain bowl of water.
3. Pry off Bolt Caps with Flat-blade screwdriver. Use wrench to remove 1/2-inch Lag Screws.
4. Swivel Toilet to gain access to back.
5. Turn off RVs power supply to the Toilet.
6. Disconnect Water Supply Line with Adjustable Wrench (Fig. B).
7. Disconnect Toilets 12-volt power hookup to RV (Fig. B).
8. Place an old towel or soft cloth on work surface. Remove Toilet from floor and place upright, with back facing you, on work surface.
9. Remove old Closet Flange Seal (may be found in toilet or in floor at Closet Flange). Discard.
10. Cover Holding Tank opening to contain odor.
Part #19617
To Remove and Replace Part
1. Rotate clockwise to remove Water Connection Fitting from Solenoid Water Valve (Fig. B). Discard old Fitting.
2. (Older version only.) If unassembled, connect new El­bow to Coupling to assemble new Water Connection Fitting.
3. Rotate counterclockwise to connect Water Connection Fitting to Solenoid Water Valve. Hand tighten. Wrench tighten 1/4 turn.
4. Reposition Elbow to accommodate RV’s water supply connection. Tighten to avoid leaks.
Fig. A
OLDER NEWER
Fig. B
Water Solenoid Valve
To Replace Toilet To Floor
1. Secure new Closet Flange Seal, lip side up, to Toi­let.
2. Position Toilet over flange.
3. If necessary, reconnect Water Supply Line.
4. If necessary, reconnect 12-volt power supply.
5. Reconnect RV’s power supply to the Toilet.
6. Turn on RVs water supply. Press Toilet flush but­ton to close blade and to flush test.
7. Secure to floor with Lag Screws. Tighten.
8. Resecure Bolt Caps.
Form #19635 Rev. 8.20.01
Water supply hookup
Power supply connector