ThermoWorks RT8400 User Manual

Talking Thermometer
RT8400
INSTRUMENT OPERATION
To turn the instrument on press the [On/Talk] button. Within one second the thermometer is ready to work. Apply the tip of the probe to the substance or medium to be measured. Wait a few seconds to allow the probe tip to come to the full temperature then press the [On/Talk] button to hear the temperature. Press the [On/Talk] button to repeat the voice message. If the temperature is currently changing, the reported reading will change. The display constantly updates once per second to show the current temperature. The instrument will automatically power off after ten minutes to maximize battery life.
SETUP AND INSTALLATION
1. Open the battery cover and remove battery insulation strip.
NOTE
1. Clean the probe immediately with cleaning wipes after each measurement to avoid cross contamination.
2. Do not expose the plastic body of the thermometer to temperatures lower than 32°F (O°C) or higher than 122°F (5O°C) otherwise incorrect readings or damage to the thermometer may result.
4. Do not expose the thermometer body to water or moisture.
SPECIFICATIONS
Measuring Range -58 to 572°F / -50 to 300°C Display Accuracy ±1.8°F / 1°C : -3.8 to 247.8°F (-19.9 to 119.9°C) ±3.6°F / 2°C : -58 to -4°F and 248 to 391.8°F (-50 to -20°C) ±5.4°F / 3°C : 392 to 572°F (200 to 300°C)
Display Resolution 0.1° over full range Response Time About 10 seconds from ambient to 212°F (100°C)
Display Reading Update 1 second Automatic Power Off After idle for 10 Minutes Battery 1.5 volt, type AAA or equivalent x 2 pieces (included) Battery Life About 4,000 hours in standby mode Probe 0.12 x 4.9 inches, Tip reduces to 0.08 inch dia.
3.0 mm x 125 mm, Tip reduces to 2.0 mm dia.
Display Size 1.0 (W) x 0.5 (H) inches 26 (W) x 12.5 (H) mm Product Size 2.0 (W) x 4.4 (H) x 1.2 (D) inches (not including probe) 51 (W) x 110 (H) x 30 (D) mms (not including probe)
ERROR SYMBOLS
Symbol Descr iptio n Action Required
Low Bat tery Replace the ba tte ries
1-Sensor open circui t
LLLL
2-Read ing is ou t of low range <-50°C
1-Sensor shor t circuit
HHHH
2-Read ing is ou t of high rang e >300° C
1-Retu rn the t hermometer for r epair 2-Keep the mea surement above the low ran ge
1-Retu rn the t hermometer for r epair 2-Keep the mea surement below th e high range