Super-Fast™ Mini
Thermometer
RT616
• IP65 water resistant
• °C/°F switchable
• Data hold function
• Max/Min reading memory
• Shuts off when probe cover replaced
• 5,700 hours battery life
Specifications
Measuring Range -40 to 302˚F (-40 to 150˚C)
Accuracy ±1.0˚F (±0.5˚C) between 14 to 212˚F (-10 to 100˚C),
otherwise ±2.7˚F (±1.5˚C)
Display Resolution 0.1˚
Reading Update 1 second
Response Time 5-6 seconds
Auto-off After 1 hour
Water Resistance IP65
Battery 3V, type CR2032 x 1 piece, 5,700 hours continuous use
Operating Range 32 to 122°F (0 to 50°C)
Probe 0.1 dia. x 2.9 L inches; reduces to a 0.06 dia. x 0.67 L inches tip
(2.5 dia. x 73 L mm; reduces to a 1.5 dia. x 17 mm tip)
Dimensions 1.02 dia. x 6.1 L inches (26 dia. x 155 L mm)
Instrument Operation
The thermometer is switched on automatically when the probe cover is removed and switched off automatically
when the probe cover is replaced. The unit will also shut off automatically af ter 1 hour and turn back on by
pressing any key.
Inser t the stainless steel probe to the desired depth. The measured temperature will be shown on the LCD display
within 5 to 6 seconds.
To Select °F or °C
Twist off the battery cap. Locate the switch under the battery. Slide the switch (°F/°C) to the desired temperature
unit. Replace the battery (CR2032) noting the correct polarity (‘+’ facing up). Replace the bat ter y cap.
Using MAX/MIN
Press MAX/MIN to display maximum recorded reading. MAX will flash on the display.
Press the button again to display minimum recorded reading. MIN will flash on the display.
Press the button once more to return to normal display.
To reset the memory, press and hold the MAX /MIN button until the display flashes ”---.-”.
Remember to reset the memory before taking new readings.
Battery Installation
Twist off the battery cap. Install the bat ter y (CR2032) noting the correct polarity (‘+’ facing up). Replace the
battery cap.
Data Hold Function
Press HOLD to retain display reading, °F or °C will flash.
Press HOLD again to return to normal display.
Care and Cleaning
Clean the probe immediately af ter each measurement to avoid cross contamination. Do not expose the entire
thermometer to temperatures over 122˚F (50˚C). Do not leave inside ovens. Not submersible.
Technical Support
For warranty, ser vice, and technical assistance, please contact ThermoWorks’ Technical Support
at (801) 756-7705 or email at techsupport@thermoworks.com.
ThermoWorks, Inc.
Utah, U.S.A.
Ph: 801-756-7705
Fax: 801-756-8948
www.thermoworks.com
P-13-001-01-b
Made in China
Follow us on:
RT616 - Super-Fast
Mini Thermometer