ThermoWorks IRT-2 Infrared Operating Instructions Manual

IRT-2 Infrared
Operating Instructions
For tips on using infrared thermometers visit the Learning Center at www.thermoworks.com.
Features
Function Keys (Press Mode button to scroll)
Lock Mode
Introduction
Open the battery compartment by pulling forward on the front handle. Insert the batteries noting the polarity. Pull the trigger, and the temperature reading of the surface being measured will be shown on the LCD display. Use the circle laser pattern to identify the target area being measured. On the side of the unit are slots to insert a type T thermocouple probe (sold separately) for contact measurements.
Infrared measurements are affected by many factors including emissivity, distance, ambient temperature, material of target being measured and many other factors. For tips on using infrared thermometers visit the Learning Center at
www.thermoworks.com.
Congratulations on purchasing a ThermoWorks precision instrument, the IRT-2 Infrared thermometer. Each instrument is factory tested and a certificate of conformance is included to ensure that it was tested against NIST-Traceable standards. Please review this operation guide prior to use.
Current emissivity setting. (The default emissivity is 0.95.)
Press ‘Mode’ button, then press ‘Up’ key or ‘Down’ key to set the emissivity. Press ‘Mode’ key to save. The emissivity is settable from 0.10 (10E) to 1 (100E).
Press ‘Mode’ button to view Maximum (MAX), Minimum (MIN), Different between MAX and MIN (DIF) and Average (AVG) modes. All functions are reset when measurements resume.
Press ‘Up’ key or ‘Down’ key to change the High Alarm (HAL) or Lo Alarm (LAL), then press ‘Meas.’ key to save. Alarm will sound and screen will flash when limits are exceeded. Alarm is for infrared measurements only.
Connect a suitable type T thermocouple probe to the connection on the side of the unit. Within the PRB function the temperature of the probe will be displayed in the lower display.
Press the “Lock” button to enable the continuous operation mode. In this mode the unit will measure without requiring the press of the trigger. Press ‘Lock’ button again to disable continuous operation mode.
LCD
Type T
Thermocouple
Socket
Down Key
Mode Key
Up Key
Meas. Key ‘Trigger
Battery Cover
Infrared Lens
Laser