ThermoWorks 231-022 User Manual

INSTRUMENT RECORD CARD
Therma Differential AquaTemp
serial no. ________________________________
calibrated by ______________date ___________
Thermistor Thermocouple
This instrument has been checked or calibrated against reference instrument(s) calibrated by a UKAS Accredited Calibration Laboratory. Traceable to NIST.
Therma Differential 231-022
AquaTemp 231-041
32°F 212°F 1832 °F
ThermoWorks, Inc.
1762 W. 20 S. #100, Lindon, UT 84042
tel: 1-801-756-7705
e-mail: info@thermoworks.com
www.thermoworks.com
INSTRUMENT OPERATION - Connect probes via the socket(s) located at the top of the instrument. (The Therma Differential uses a miniature type K thermocouple connector and the AquaTemp uses a 6 pin Lumberg screw locking type connector). Switch the instrument on and apply the tip of the probe to the substance or medium to be measured. The instrument reading may take a few seconds to stabilize, depending on the nature of the measurement and sensitivity of the probe. HOL D - Press th e HOLD bu tton to s top measurements, press again to continue measuring. AUTO-OFF - The unit will switch off automatically after 10 minutes. To disable auto-off press the HOLD button while switching on the instrument (this is reset when the instrument is switched off). OPEN CIRCUIT/FAULTY PROBE - If the probe has developed an 'Open Circuit' fault the instrument will display 'Err'. SENSORS - The Therma Differential should only be used with type K (Nickel Chromium/Nickel Aluminium)
50212). The AquaTemp can be used with either an interchangeable thermistor probe or a type T thermocouple probe fitted with 6 pin Lumberg screw locking connectors. This instrument is designed to be compatible with ThermoWorks’ probes. BATTERY REPLACEMENT - The instrument will display a low battery symbol to warn that the batteries will need changing soon. The instrument continues to measure accurately but after further usage the instrument will display 'flat bat' and shutdown. Replace the three AAA batteries located under the rear case half that is held in place by six screws. Check the seal for damage and carefully replace the rear case half and tighten the screws.
thermocouple plugs (to BS EN
P-12-006/7-02-a
547-170/28.03.12
MAX/MIN - Press the MAX/MIN button to display the values. The instrument retains the max/min values when switched off. To reset, press the MAX/MIN button for three seconds, 'rst' will be displayed. BACKLIGHT - Press the HOLD button for two seconds to turn backlight on or off. Backlight will timeout after 20 seconds. (Please Note: the backlight will not operate if the low battery symbol is being displayed.) CALIBRATION TRIM - (AquaTemp only) Press the MAX/MIN and ON/OFF buttons at start up for five seconds to enter ('Offset' is displayed). Press MAX/MIN to cycle (continuous loop) the trim value in 0.1 steps up to ±2.0 ºC (3.6 ºF). Press ON/OFF to save the value and exit Trim mode. MODE - (Therma Differential only) Press the MODE button to scroll through T1, T2 or T1 - T2. While displaying T1-T2, press the MODE button for three seconds to reset the differential reading to 0.0 °C/°F. °C/°F - Press and hold ON/OFF button for five seconds at start-up. GUARANTEE - This instrument carries a one-year warranty against defects in either components or workmanship. prove to be defective will, at the discretion of ThermoWorks, be either repaired or replaced without charge. This warranty does not apply to probes, where a six-month period is offered. The product warranty does not cover damage caused by fair wear and tear, abnormal storage condi­tions, incorrect use, accidental misuse, abuse, neglect, misapplication or modification. Full details of liability are available within Thermo­Works’ Terms & Conditions of Sale at www.thermoworks.com. In line with our policy of continuous development, we reserve the right to amend our product specification without prior notice.