Thermomax Solar Water Heater
Installation Manual
..........
Installation Procedure for Flatroof and Ground
Revision 8
2
. .
. . . .
.
.
.
.
Thermomax Solar Water Heater Installation
CAUTIONS
YOU MUST THOROUGHLY READ BASIC GUIDE FOR THERMOMAX TECHNICAL DETAILS & INSTALLATION MANUAL BEFORE COMMENCING SYSTEM INSTALLATION
1. The Thermomax tubes should under no circumstances be exposed to the sun
for extended periods (maximum one day) if the system has not been filled. No load operation of the system will permanently damage Thermomax tubes.
2. The circulating pump should under no circumstances be switched off during
a sunny day. This will create a high temperature and as a result, high pressure in the system. When not in use for extended periods, the circulating pump must be left switched on and a by-pass should divert the heat from the storage tank.
3. The contractor shall verify true south and shall orient the collector tubes
facing true south. The collector tilt angle shall be nominally set at latitude but never less than 25°. At a lower inclination, the output of the collector
will be reduced.
4. Unpack and install the collector tubes AFTER the manifold unit and pump
has been installed and the piping has been connected.
5. Gloves and eye protection should be worn when handling the glass.
6. Avoid any sudden shock to the tubes.
7. Avoid scratching the glass collector tubes, as this will reduce their strength.
8. ALL LOCAL AUTHORITIES REGULATIONS AND RELEVANT
STANDARDS SHOULD BE FOLLOWED.