Table of contents
1. Preface 3
2. Specifications
2.1 Performance Data 4
2.2 Dimensions 6
3. Installation and Connection
3.1 Heat Pump Location 8
3.2 How Close to Your Pool? 8
3.3 Installation illustration 9
3.4 Installation of a check valve 9
3.5 Electrical Wiring 10
3.6 Initial Start-up of the Unit 10
3.7 Condensation 11
4. Operation and Use
4.1 Display interface introduction
12
4.2 Button functions
13
4.3 Error codes
17
4.4 Error code list
18
5. Wiring diagrams
5.1 Wire control interface diagram and definition
20
5.2 Controller interface diagram and definition
20
6. Maintenance and Inspection
23
6.1 Wi-Fi Module 23
7.Appendix
7.1 Caution & Warning 24
7.2 Warranty 25
3
1. Preface
In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance. It is vital that the instructions within this manual are adhered to at all times. The unit must be installed by qualified personnel.
The unit can only be repaired by qualified personnel or an authorized dealer.
Maintenance and operation must be carried out according to the recommended time and frequency, as stated in this manual.
Use genuine standard spare parts only. Failure to comply with these recommendations will invalidate the warranty.
Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant.
Our heat pump has following characteristics:
Durable
The heat exchanger is made of PVC & Titanium tube which can withstand prolonged exposure to swimming pool water.
Installation flexibility
The unit can be installed outdoors or indoors.
Quiet operation
The unit comprises an efficient rotary/ scroll compressor and a low-noise fan motor, which guarantees its quiet operation.
Advanced controlling
The unit includes micro-computer controlling, allowing all operation parameters to be set. Operation status can be displayed on the LCD wire controller. Remote controller can be chosen as future option.
4
2. Specifications
2.1 Performance data
UNIT
Thermotec Inverter 29
Thermotec Inverter 34
Max Pool
volume*
m
3
116
136
Advised Max Pool
volume **
m
3
93
109
Operating air
temperature
°C
-15 to 43
Air 27°C / Water 26°C / Humidity
80%
Heating
Capacity
kW 6.7 –
28.6
8.0 – 34.0
Btu
22780 – 97240
27200 – 115600
Consumed
power
kW
0.53 – 5.4
0.64 – 6.6
COP
5.3 – 12.64
5.15 – 12.5
Air 15°C / Water 26°C / Humidity
70%
Heating
Capacity
kW
5.5 – 23.4
6.6 – 27.8
Btu
18700 – 79560
22440 – 94520
Consumed
power
kW
0.82 – 5.4
0.99 – 6.5
COP
4.33 – 6.71
4.28 – 6.67
Air 10°C / Water 26°C / Humidity
64%
Heating
Capacity
kW
4.9 – 20.9
5.9 – 24.8
Btu
16660 – 71060
20060 – 84320
Consumed
power
kW
0.86 – 5.05
1.05 – 6.1
COP 4.14 – 5.7
4.07 – 5.62
Power
supply
230V / 50Hz
Nominal Heating
Capacity
kW
11.8
15.1
Nominal power
input
kW
2.4
3.1
Max power
input
kW
28.6
33.7
Nominal Running
current
A
10.7
13.5
Current
range
A
2.5 to 30
3.1 to 30.6
Max
Current
A
30
30.6
Compressor
quantity
1 1
Compressor
type
Rotary
Rotary
Refrigerant
R410A
Fan
quantity 1 1
Fan power
input
W
200 200
Fan rotary
speed
RPM 600 -
800
500-800
Fan
direction Vertical
Vertical
Noise at 1m
dB(A)
49 - 60
50 - 61
Noise at 10m
dB(A)
33 - 43
35 - 45
Water
connection
mm
50 50
Nominal water
flow
m3/h
9.5 11.5
Water pressure
drop (max)
kPa
16 20
Unit net
dimensions (L*W*H)
mm 920 x 960 x 1025
920 x 960 x 1025
Unit
shipping dimensions (L*W*H)
mm 970 x 1010 x 1075
970 x 1010 x 1075
Net
weight
kg 113 118
Shipping
weight
kg 148 156
* Max pool volume for an entirely insulated pool, with cover, free from wind and exposed to the sun
In case the pool volume is close to the maximum value, the inverter heat pump will nearly always run at full power
** Advised pool volume for efficient heating
5
2.2 Dimensions
Thermotec Inverter Vertical 29kw and 34kw
Thermotec Inverter 17 / 19.5
2.3 Removing the Case
6
2.4 Connecting the Power Cable
To connect the powe cable, please remove the front panel of the heat pump and connect the power cable to the terminal block on the fron of the heat pump
7
3. Installation and Connection
3.1 Heat Pump Location
The unit will perform well in any outdoor location provided that the following three factors are presented:
1. Fresh Air - 2. Electricity - 3. Pool filter piping
The unit may be installed virtually anywhere outdoors. For indoor pools please consult the supplier. Unlike a gas heater, it has no draft or pilot light problem in a windy area.
DO NOT place the unit in an enclosed area with a limited air volume, where the units discharge air will be re-circulated.
DO NOT place the unit to shrubs which can block air inlet. These locations deny the unit of a continuous source of fresh air which reduces its efficiency and may prevent adequate heat delivery.
3.2 How Close To Your Pool?
Normally, the pool heat pump is installed within 7.5 meters of the pool. The longer the distance from the pool, the greater the heat loss from the piping. For the most part, the piping is buried. Therefore, the heat loss is minimal for runs of up to15 meters(15 meters to and from the pump = 30 meters total), unless the ground is wet or the water table is high. A very rough estimate of heat loss per 30 meters is 0.6 kW-hour,(2000BTU) for every 5°C difference in temperature between the pool water and the ground surrounding the pipe, which translates to about 3% to 5% increase in run time.
8
3.3 Installation illustration
Remarks:
The factory only provides the heat pump. Other parts, including a contingent by-pass are to be provided by the user or installer.
Attention:
Please take the following steps when installing the heat pump:
1. Each addition of chemicals has to be performed through the conduits located AFTER the heat pump.
2. Install a by-pass for easy maintenance
3. Always place the heat pump on a solid base and use the supplied silent blocks in order to avoid vibrations and noise.
4. Always keep the heat pump in upright position. If the unit has been tilted, you should wait for at least 24 hours before turning it on.
3.4 Installation of a check valve
When using automatic chlorine and pH dosage systems, it is of uttermost importance to protect the heat pump from high concentrations of these chemicals that could corrode the heat exchanger Therefore, such systems should add the chemicals in the conduits located DOWNSTREAM of the heat pump and it is recommended to install a check-valve in order to prevent backflow when there is no water circulation. Damage to the heat pump caused by disregarding any of these recommendations will invalidate the warranty.