ThermoTec Pro Heat Pump Pool Heater, Pro Installation & Operating Instructions Manual

INSTALLATION & OPERATING
INSTRUCTIONS
ThermoTec Pro
Heat Pump Pool Heater
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire.
NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components. Installation and service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install, service, or maintain this equipment.
This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a safe place for future use.
Effective: 12-30-09 Replaces: NEW P/N 241388 Rev. 1
2
Water Chemistry
(Corrosive water voids all warranties)
or your health and the protection of your pool equipment, it is essential that your water be chemically
F balanced. The following levels must be used as a guide for balanced water.
Recommended Level(s) Fiberglass Pools Fiberglass Spas Other Pool & Spa Types
Water Temp. (Deg. F) 68 to 88 89 to 104 68 to 104
pH 7.3 to 7.4 7.3 to 7.4 7.6 to 7.8
Total Alkalinity (PPM) 120 to 150 120 to 150 80 to 120
Calcium Hardness (PPM) 200 to 300 150 to 200 200 to 400
Salt (PPM)
Free Chlorine (PPM)* 2 to 3 2 to 3 2 to 3
Total Dissolved Solids (PPM)
*Free Chlorine MUST NOT EXCEED 5 PPM!
Occasional chemical shock dosing of the pool or spa water should not damage the heater providing the water is balanced.
Automatic chemical dosing devices and salt chlorinators are usually more efficient in heated water. Unless controlled, they can lead to excessive chlorine level which can damage your heater.
Further advice should be obtained from your pool or spa builder, accredited pool shop, or chemical supplier for the correct levels for your water.
6000 MAXIMUM 6000 MAXIMUM 6000 MAXIMUM
3000 MAXIMUM 3000 MAXIMUM 3000 MAXIMUM
3
CONTENTS
Water Chemistry 3 Warnings 5
Pay Attention to These Terms 5
Introduction 6 Installation Considerations 6 Electrical Connections 7 Water Connections 8 Controls & Indicator Lamps (Analog Models) 8 System Start-Up 9 Controls (Digital Models) 10 Digital Controls Operating Instructions 10
To Select Pool or Spa Mode 10 To Increase the Desired Water Temperature (Pool or Spa Mode) 10 To Lower Desired Water Temperature (Pool or Spa Mode) 10 To Select Temperature in °C or °F 10
System Start-Up 11 Seasonal Start-Up or Annual Check 11 Summer Shutdown 11 Freeze Protection 11
System Drain-Down 11 Continuous Pump Operation 11
Maintenance 12
Air Coil Cleaning 12 Cabinet Care (optional) 12 Unplug Condensation Drain Holes 12
Troubleshooting 12 Service Call Verification 13
Power Supply 13 Water Flow 13 Time Clock Adjustment 13
Plumbing Diagrams 15 Wiring Diagram — 200V/220V Single-Phase — Analog Models 19 Wiring Diagram — 200V/220V Single-Phase — Digital Models 20 Wiring Diagram — 220V & 380V Three-Phase — Analog Models 21 Wiring Diagram — 220V & 380V Three-Phase — Digital Models 22 Installing a Remote Control Device 23
Wiring 23 Heater Settings 23
4
Warnings Pay Attention to These Terms
ndicates the presence of immediate hazards which will cause severe personal injury, death
DANGER:
I or substantial property damage if ignored.
WARNING:
CAUTION:
NOTE:
This manual, as well as the pool/spa heat pump pool heater itself, contains ANSI-approved product safety signs and labels. Please read these signs and labels, as they convey important safety information about hazards that may be potentially present in and around the heat pump pool heater.
CAUTION: Elevated water temperature can be hazardous. The U.S. Consumer Product Safety Commission has these guidelines:
1. Spa water temperatures should never exceed 104°F (40°C). A temperature of 100°F (38°C) is considered safe for a healthy adult. Special cau­tion is suggested for young children.
2. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subsequently result in drowning.
Indicates the presence of hazards or unsafe practices which could cause severe personal injury, death or substantial property damage if ignored.
Indicates the presence of hazards or unsafe practices which could cause minor personal injury or product or property damage if ignored.
Indicates special instructions on installation, operation, or maintenance which are important but not related to personal injury hazards.
CAUTION: Improper chemical content in a swim­ming pool or spa can damage the heat pump pool heater. DO NOT add pool chemicals to the skimmer. This will damage the heat pump pool heater and could void the heat pump pool heater warranty. ALWAYS follow the product manufacturer’s direc­tions when adding any chemicals to your pool.
WARNING: These heat pump pool heaters are charged with R-407C refrigerant. Ensure that all service work is done with gauges and equipment suitable for R-407C.
3.
Pregnant Women Beware!
102°F (39°C) can cause fetal damage during the first three months of pregnancy resulting in the birth of a brain-damaged or deformed child. Pregnant women should stick to the 100°F (38°C) maximum rule.
4. Before entering the spa or hot tub, users should check the water temperature with an accurate thermometer; spa or hot tub thermostats may err in regulating water temperatures by as much as 4°F (2.2°C).
5. Persons with a medical history of heart disease, circulatory problems, diabetes, or blood pressure problems should obtain a physician's advice before using pools or hot tubs.
6. Persons taking medications which induce drowsi­ness, such as tranquilizers, antihistamines, or anticoagulants, should not use spas or hot tubs.
Soaking in water over
5
Introduction
WARNING: This pool/spa heat pump pool heater is
n electromechanical machine that incorporates a
a pressurized refrigerant gas in a sealed system.
NLY trained and qualified service personnel are
O authorized to install or service this equipment. Without proper training and knowledge of such equipment, any attempt to install or service the unit could result in serious injury or even death.
This manual contains important information on the use, maintenance and troubleshooting of your new heat pump pool heater. This unit must be properly installed, maintained and operated for optimal per­formance.
Installation Considerations
ARNING: Do not install the unit within 3 ft of
W
fossil fuel burning heaters. Air intake along the sides of this heat pump pool heater could disturb the combustion process of the unit, and could
ause damage or personal injury.
c
• Mount the unit on a level, sturdy base, preferably a concrete slab or blocks. The size of the base should be at least 3 ft by 3 ft.
• You must install the 4 black rubber sound iso­lation pads (each 2 inches square) that ship with the unit. The pads are shipped in a bag with the unions, gaskets and the I&O manual. Install pads under the 4 corners of the unit to reduce vibra­tion and sound transmission to the base.
This heat pump pool heater is an extremely efficient, economical machine designed specifically for swim­ming pool heating. It is similar in design and operation to a typical residential air conditioning system. The unit employs a hermetic motor/compressor operating in a refrigeration cycle to extract heat from ambient air and deliver it to the circulating pool water.
As with all heat pump pool heaters, compared to other types of heaters such as gas or oil-fired, this heat pump pool heater has lower heating capacity on a BTUH/hr basis. As a result, it will be required to oper­ate longer to accomplish the desired results. It may, at certain times, operate as much as 24 hours per day. However, this should not be of concern to the owner, because the unit is designed to operate continuously. Even though it may operate continuously for many hours, it will still heat the pool with greater economy than other types of fossil fuel heaters.
Place a cover or blanket over the pool at night and other non-use periods. This will keep evaporation, the cause of main heat loss, to a minimum, and will great­ly reduce pool heating costs. During warmer weather, the cover may be required only at night.
CAUTION: The unit’s supporting base must be high enough to keep it completely free of standing water at all times.
Situate the heat pump pool heater carefully to mini­mize installation costs while providing maximum efficiency of operation, and to allow adequate service access, as follows:
For unrestricted air intake and service access, position each side of the unit at least 1 ft (30 cm) from walls, pipes and other obstructions.
WARNING: This unit is designed for outdoor instal­lation; DO NOT install it in an enclosed area such as a shed or garage.
Recirculation of cold discharge air back into the evaporator coil will greatly reduce the unit’s heat­ing capacity and efficiency.
This unit features an ‘up-flow’ discharge for quiet operation. Air is pulled up through the evaporator coil and discharged through the top grill. Allow at least 5 ft (1.5 m) clearance above the unit for unre­stricted air discharge. DO NOT install the unit under a porch or deck. Refer to Fig. 1.
To minimize water piping, locate the unit as close as possible to the existing pool pump and filter.
6
GAS HEATER
A
IR FLOW IN
A
IR FLOW IN
AIR FLOW OUT
3 FT MIN
12”
MIN
60”
MIN
Fig. 1: Installation Clearances
When installed in areas where freezing tempera­tures can be encountered, drain the water circuit to prevent possible freeze-up damage. See the Freeze Protection Section.
For high wind installation requirements, refer to the diagram on page 8.
Electrical Connections
Refer to the unit rating plate below the control panel for precise power requirements for your unit, and for ampacity and over-current protection requirements.
Locate the equipment disconnect means within 3 feet of the heater’s electrical enclosure, or as close to the heater as possible. Always satisfy
applicable codes and standards.
In sizing power wiring, be especially aware of up­sizing requirements necessary due to wiring distances. Always satisfy applicable codes and standards.
Electrical installation should be done by a licensed electrician only.
This unit is pre-wired to work with external control sys­tems, heat-on-demand options and other external time clock overrides. Refer to the external control system’s instructions, and page 23 of this manual, for installa­tion information.
7
WATER IN
WATER OUT
Fig. 2: Water Connections
CAUTION: The heat pump pool heater inlet and outlet connections are NOT interchangeable. They must be connected as instructed below.
1. Connect the heat pump pool heater in the return water line between the filter and the pool/spa. See the Plumbing Diagrams beginning on page 16.
2. Connect the filter outlet to the fitting marked WATER IN at the bottom front of the unit.
3. Connect the fitting marked WATER OUT to the return piping to the pool/spa. Unit inlet/outlet con­nection fittings are 2-inch PVC unions.
Water connections from the unit to the main return line can be PVC pipe or flexible pipe approved for the purpose and, in either case, should be at least equal in size to the main pool/spa circulation pip­ing.
4. In cold weather (freeze zone) areas, shutoff valves (ball or gate type) must be installed at the unit inlet and outlet to facilitate service and cold weather drain-down.
5. Operate the pump and check the system for leaks.
WARNING: Install a check valve and/or a Hartford loop AFTER the heat pump pool heater and BEFORE any chlorinating devices. Install any auto­matic chemical feeders AFTER the heat pump pool heater. Improper installation of any type of auto-
matic chemical feeders can result in serious damage to, or premature failure of, the heat pump pool heater and will void the heat pump pool heater warranty.
8
Digital Controls Operating Instructions
The electronic board has the capability of memorizing two different programmed temperature settings as fol­lows (refer to Fig. 5):
For a pool, maximum 95°F (35°C)
Controls (Digital Models)
Your heat pump pool heater incorporates digital safety controls and indicators to ensure its safe, reliable operation (for models with analog controls, see page
8).
Water Pressure Switch: Prevents operation when the pump is OFF. The unit requires 5 psi minimum pres­sure.
Digital Water Temperature Control: The pool water temperature is controlled by the heat pump pool heater’s digital control system, which gives you the option of two settings: one for the desired spa temper­ature and the other for the desired pool temperature. Additionally, as mentioned earlier, the unit is compati­ble with most ‘2-wire’ and ‘3-wire’ control/automation systems.
For a spa, maximum 104°F (40°C)
To Select Pool or Spa Mode
To have access to either one of these programs, press the SET key until you see P _S and by pressing the UP or DOWN key you can switch to POL or SPA.
To Increase the Desired Water Temperature (Pool or Spa Mode)
Push the SET key until you see POL or SPA. The pro­grammed temperature will be displayed. Press the UP arrow to increase the temperature setting one degree at a time.
To Lower the Desired Water Temperature (Pool or Spa Mode)
Push the SET key until you see POL or SPA. The pro­grammed temperature will be displayed. Press the DOWN arrow to decrease the temperature setting one degree at a time.
Fig. 5: Digital Water Temperature Control
Defrost Sensor: Prevents unit operation if ambient air
temperature falls below a predetermined safe mini­mum (approximately 42°–48°F, based on humidity). The compressor will shut OFF but the fan will continue to run.
Delay Timer: Prevents compressor from short cycling, which could damage or destroy the hermetic motor/compressor. Upon water temperature control satisfaction, or other circuit interruptions, this solid state device will prevent compressor restart for approximately 5 minutes.
Once the control has been programmed to the desired pool water temperature, the programmed temperature will be displayed for approximately 5 seconds. Then the digital display will display the actual pool water temperature.
To Select Temperature in °C or °F
Press the SET key until you see F _C. By pressing the UP or DOWN key you can switch to °F or °C. Once the temperature display mode has been programmed it will be displayed for approximately 5 seconds, then the digital display will return to the actual pool water temperature in the mode that you have chosen.
10
System Start-Up
Summer Shutdown
. Verify that the Digital Board is displaying a temper-
1
ature and the pool pump is running and water is
irculating properly.
c
2. Verify that the Board is programmed so that the desired temperature of the Pool and Spa is higher than the displayed current water temperature.
3. Allow the heat pump pool heater to operate for a few minutes to stabilize operating pressures and to allow various component temperatures to normal­ize.
4. Verify that the discharge air temperature is approx­imately 8°–10°F cooler than the air entering the unit. If not, see the Troubleshooting Section.
Seasonal Start-Up or Annual Check
NOTE: At the beginning of the heating season, or
whenever the pool water temperature is to be raised several degrees, the pool pump and heat pump pool heater may need to operate continuously for several days. During summer months, only a few hours per day may be necessary, or none at all.
1. Remove leaves, pine needles, etc., from the evap­orator coil. Clean the coil by gently applying a mild solution of household liquid soap and water.
If you do not plan to use the heat pump pool heater
uring the summer months, secure and protect it as
d follows:
1. Turn the unit circuit breaker or disconnect switch to OFF.
2. Leave the valves set the way they are unless addi­tional circulation is required. DO NOT stop all flow through the heat pump pool heater.
3. IMPORTANT: Remember to reset the valves before the next heating season, or the unit will not operate properly.
Freeze Protection
If the unit is installed in a location subject to freezing conditions, it is important to protect the water circuit from freezing, just as should be done for the pump and filter.
System Drain-Down
1. Turn the unit circuit breaker or disconnect switch to OFF.
2. With the pool pump OFF, close the external shut­off valves and loosen the inlet and outlet water unions to allow water to drain. Use a Wet/Dry Vac or air pressure to remove excess water.
3. Loosely re-attach the unions.
2. Gently rinse the coil with water; DO NOT use high pressure.
3. Backwash or otherwise clean the pool filter. If nec­essary, clean the skimmer basket and pump strainer.
NOTE: If the pool pump and heat pump pool heater shut OFF before the water temperature is raised to the desired level, you must lengthen the running time of both. To do this, reset the time clock dial for the longer running time, or manually operate the pump with the timer override switch. Since the heat pump pool heater capacity and efficiency are both greater at higher ambient air temperatures, run time should be set to take advantage of all daylight hours, when the air is generally warmer.
4. Set the valves to ensure proper water flow through the unit.
4. Cover the unit with a waterproof cover.
Continuous Pump Operation
It is also possible in some areas to prevent unit freeze damage by operating the pump continuously during freezing weather. However, this results in significantly higher pump operating costs. Further, if a sustained power failure occurs, the unit MUST be drained any­way, or freeze damage could result.
11
Maintenance
Troubleshooting
NOTE: The heat pump pool heater MANUFACTUR-
ER IS NOT RESPONSIBLE for maintenance adjustments.
The following maintenance procedures are designed to keep your unit operating at a high level of reliability.
Maintenance must be performed on a periodic basis to maintain warranty coverage and prevent
system failures and performance degradation.
Air Coil Cleaning
Efficient operation depends on free circulation of air through the thin and tightly-spaced fins of the evapo­rator coil(s). The evaporator must be cleaned whenever it has a buildup of dirt or debris.
CAUTION: To clean the fins, spray gently with a garden hose. DO NOT pressure wash. Doing so will bend the fins and can void the warranty.
Cabinet Care (optional)
The cabinet is designed for outdoor use and requires little care. However, you can clean it if you wish.
f your unit does not operate, or simply does not heat
I your pool water, Fault Codes (digital models), or the indicator lamps (analog models) on the front control panel, can provide valuable clues as to what is wrong, and may even indicate precisely what the problem is. Always observe these codes (or lamps) before calling a service representative. By reporting on the tele­phone the Fault Codes (or which lamps are ON or OFF) that are showing, the service rep may be able to solve the problem without the expense of a service call.
A. UNIT IS RUNNING, BUT NOT HEATING
Is water flow through the unit adequate? Check
the unit for obstructions, such as a clogged filter pump strainer, a dirty filter, or valves not posi­tioned correctly.
Is the ejected air from the unit 8°–10°F cooler than incoming air? If so, the unit is extracting heat from the air and transferring it to the pool.
Is water condensing on the evaporator and inter­nal copper pipes? This is also evidence of heat removal from the air. When the air is cool with low humidity, condensation may not be evident.
WARNING: Shut OFF electricity to the unit before cleaning.
Wash the cabinet with soap and water.
Unplug Condensation Drain Holes
The unit extracts humidity from the air as it passes through the coil, similar to the way a cold drink outside “sweats” on a hot day. This condensation drains from the bottom of the unit.
1. Routinely check to be sure the condensation drain holes in the base of the unit are not plugged with dirt or debris.
2. If condensation becomes a problem, optional drain pans are available from your heat pump pool heater distributor or pool dealer.
How long has the unit been operating? During ini­tial pool heating in cold weather, it may require a week to elevate the water temperature to a com­fortable level. Normally, it takes about 4 days.
How many hours per day is the unit operating?
Remember that the heat pump pool heater only operates while the pool pump is running. Set the
time clock to permit 24 hour per day operation. After the desired temperature is reached, return the unit to normal operation of 8–10 hours per day.
NOTE: If the pool pump and heat pump pool heater shut OFF before the water temperature is raised to the desired level, you must lengthen the running time of both. To do this, reset the time clock dial for the longer running time, or manually operate the pump with the timer override switch. Since the unit capaci­ty and efficiency are both greater at higher ambient air temperatures, run time should be set to take advantage of all daylight hours, when the air is gen­erally warmer.
Is airflow through the unit being obstructed? Restrictions such as shrubbery, tall grass, dirty
12
oils, or any other obstruction to airflow will reduce
c performance.
Is the pool blanket/cover being used? nblanketed pools can lose up to 10 degrees per
U night compared to 4 degrees or fewer when a blanket is used. Without a blanket, the total heat gained during the day can be lost overnight.
Are rapid heat losses occurring in some other way,
such as high wind, spillage, rainfall, flow through solar panels at night, or a high water table?
B. UNIT IS NOT RUNNING
Is the temperature display or control panel Power
lamp ON? If not, the circuit breaker may be shut OFF or tripped. Reset the breaker by switching it OFF, and then back ON. Verify that the breaker
is set and operating properly before calling for service.
Is the thermostat setting and the Pool/Spa setting
correct? Verify that the temperature has been properly set on the thermostat, and that it is high- er than the current water temperature. On analog units, all 3 lamps should be illuminated and the fan should begin to run.
Service Call Verification
Before you make a service call, first determine if the
roblem is:
p
Warranty Service
Unit operation (power supply, water flow, or time
clock adjustment)
NOTE: The MANUFACTURER IS NOT RESPON- SIBLE for these adjustments.
Power Supply
Verify that all circuit breakers are reset and work­ing properly.
If the temperature display or the Power lamp on the control panel still does not light, contact the installing dealer, since it may be a power problem requiring an electrician.
Water Flow
Verify that the pool filter is clean to provide good flow.
Have you waited approximately 5 minutes for the time delay? After the unit has been running and then shut OFF for any reason, there is a delay before operation can begin again.
Is the Heat Light or Heat Demand lamp ON? If not, then the thermostat setting is not higher than the temperature of the water. Raise the thermostat setting.
NOTE: The heat pump pool heater will not run when the Remote position is selected on the Pool/Spa selector switch and there is no remote control sys­tem attached.
C. CONDENSATION SEEMS EXCESSIVE
Heat pump pool heaters can produce a large amount of condensation (water) during operation. If you sus­pect that the unit is leaking:
a. Use a pool chemistry test kit to confirm there is no
chlorine in the condensation. Or,
b. Shut the unit OFF and leave the filter pump run-
ning to see if the water stops dripping. If the water stops dripping, the unit is not leaking.
Verify that valves are properly positioned to allow adequate water flow through the unit.
If the Water Flow lamp (analog models) on the control panel still does not light, and water is circu­lating in the pool, verify that all valves are positioned correctly.
Time Clock Adjustment
Verify that the time clock is set to permit the unit to run long enough to heat properly.
13
Fault Code Meaning of Code
OFF The desired programmed temperature point is lower than 60°F (15°C).
hortage of refrigerant gas in the unit or faulty low pressure control. The unit will show
S
LP & LP3
(LP3) after 3 LP faults and shuts down the unit and pool pump for protection. If this
ccurs, you should call for service.
o
HP & HP3
Low water flow in the unit or faulty high pressure control. Check water flow/backwash. The unit will show (HP3) after 3 HP faults. This will stop the unit for protection.
Possible causes:
• The filter is in backwash position.
• The filter pump is stopped.
• The filter is dirty.
FLo & FL3
• Shortage of water to pool pump.
FIL parameter must be set to activate pool pump.
• Water pressure switch must be adjusted or it is broken.
• The unit is in the protection mode and will show (FL3), press any key to restart the unit. FL3 code will stop the unit and pool pump.
FS
Unit is in the defrosting cycle. (The fan works but the compressor is stopped.)
- - Keypad is pressing down on both buttons. Replace keypad.
Table A: Control Board Fault Codes — Digital Models
14
Plumbing Diagrams
WATER IN
(FROM POOL OR
SPA)
FILTER
CHECK
VALVE
CHEMICAL
INTRODUCTION
WATER OUT
(TO POOL OR
SPA)
Fig. 6: For systems with pumps of less than 2 HP (under 80 gpm), no external
bypass is required. Connections are 2-inch unions. Plumb the heat
pump pool heater AFTER the filter and BEFORE any chlorinators.
15
WATER IN
(FROM POOL OR
SPA)
FILTER
CHECK
VALVE
CHEMICAL
INTRODUCTION
WATER OUT
(TO POOL OR
SPA)
Fig. 7: For systems with pumps of 2 HP or greater (over 80 gpm), an external
bypass is required. Adjust the bypass valve to divert a minimum of 40
gpm through the heat pump pool heater. Connections are 2-inch unions. Plumb the
heat pump pool heater AFTER the filter and BEFORE any chlorinators.
16
Fig. 8: Pool Piping for Heat Pump Pool Heater and Gas Pool Heater
17
UNITS
UNITS
UNITS
Fig. 9: Pool Piping for Heat Pump Pool Heaters, Multiple, Primary/Secondary
18
Wiring Diagram — 200V/220V Single-Phase — Analog Models
19
Wiring Diagram 200V/220V Single-Phase Digital Models
20
Wiring Diagram — 220V & 380V Three-Phase — Analog Models
21
Wiring Diagram 220V & 380V Three-Phase Digital Models
22
Installing a Remote Control Device on Analog Heaters
Installing a Remote Control Device on Digital Heaters
Wiring
For a 2-wire control, use the TOTAL and COMMON connections on the heat pump pool heater wiring block.
For a 3-wire control, use the COMMON, SPA and POOL connections on the heat pump pool heater wiring block.
Wiring
For a 2-wire control, use the TOTAL and COMMON
onnections on the heat pump pool heater wiring
c block.
For a 3-wire control, use the COMMON, SPA and POOL connections on the heat pump pool heater wiring block.
Fig. 10: Heater Wiring Block — Analog Heaters
Heater Settings
1. To operate the heater using a 2-wire remote con­trol device, simply switch the Spa-Remote-Pool knob to the Remote position and make sure the heater is enabled on the remote control device.
2. To operate the heater using a 3-wire remote con­trol device, simply switch the Spa-Remote-Pool knob to the Remote position and set the tempera­ture for pool and spa.
Fig. 11: Heater Wiring Block — Digital Heaters
Heater Settings
1. Make sure the heater is disabled on the remote
control device. Then, push the SET key until POL is displayed. Push the DOWN arrow key until OFF is displayed. Wait until a temperature is displayed before beginning the next step.
2. Push the SET key until SPA is displayed, then
push the UP arrow to 104°F. Wait until a tempera­ture is displayed before beginning the next step.
3. Push the SET key until P_S is displayed, then
push the DOWN arrow until POL is displayed. Wait until a temperature is displayed before begin­ning the next step.
4. Finally, enable the heater on the remote control
device. When there is a call for heat, the heater display will show SPA. When the heater is dis­abled, the display will show POL.
23