ThermoTec LCSPI-120, LCSPI-150, LCSPI-210, LCSPI-170, LCSPI-250 Operation & Installation Manual

...
RENEWABLE HEATING & COOLING TECHNOLOGY
Swimming Pool Heat Pump
Enjoy longer swimming seasons with less cost
Operation & Installation Manual
TABLE OF CONTENT
!
BEFORE OPERATING THE UNIT, ENSUR E TH E IN STALLATION HAS BEEN CAR RI ED OUT IN ACCORDANCE WITH THESE INSTRUCTIONS. IF IN DOUBT CONS ULT YOUR LOCAL DEALER.
!
INTRODUCTION This manual
The Heat Pump SAFETY INSTRUCTIONS Warning Caution
CONTENTS OVERVIEW OF THE UNIT
INSTALLATION
Installation guidelines Locating your Unit Water connection Electrical connection Trial running OPERATING THE UNIT Features and functions User interface Buttons Controller operations
PARAMETER CHECKING
Unit Status Query Table Parameter settings
ERROR CODES MAINTENANCE TROUBLESHOOTING ENVIRONMENTAL INFORMATION DISPOSAL REQUIREMENTS WIRING DIAGRAM TECHNICAL SPECIFICATIONS
Page 1
RENEWABLE HEATING & COOLING TECHNOLOGY
EXPLODED VIEW
………… … … … … … … … … … … … … … ……………………2 ………… … … … … … … … … … … … … … ……………………2 ………… … … … … … … … … … … … … … ……………………2 ………… … … … … … … … … … … … … … ……………………2 ………… … … … … … … … … … … … … … ……………………2 ………… … … … … … … … … … … … … … ……………………3 ………… … … … … … … … … … … … … … ……………………4 ………… … … … … … … … … … … … … … ……………………5 ………… … … … … … … … … … … … … … ……………………6 ………… … … … … … … … … … … … … … ……………………7 ………… … … … … … … … … … … … … … ……………………7 ………… … … … … … … … … … … … … … ……………………7 ………… … … … … … … … … … … … … … ……………………7 ………… … … … … … … … … … … … … … ……………………8 ………… … … … … … … … … … … … … … ……………………8 ………… … … … … … … … … … … … … … ……………………9 ………… … … … … … … … … … … … … … ……………………9 ………… … … … … … … … … … … … … … ……………………9 ………… … … … … … … … … … … … … … ……………………9 ………… … … … … … … … … … … … … … ……………………9 ………… … … … … … … … … … … … … … ……………………12 ………… … … … … … … … … … … … … … ……………………12 ………… … … … … … … … … … … … … … ……………………12 ………… … … … … … … … … … … … … … ……………………13 ………… … … … … … … … … … … … … … ……………………14 ………… … … … … … … … … … … … … … ……………………14 ………… … … … … … … … … … … … … … … ………15 ………… … … … … … … … … … … … … … ………………15 ………… … … … … … … … … … … … … … ……………………17 ………… … … … … … … … … … … … … … ………………19
Page 2
RENEWABLE HEATING & COOLING TECHNOLOGY
INTRODUCTION This manual
This manual includes the necessary information to or damage safely install and maintain your Heat Pump. Please read this manual carefully before you operate the unit.
The Heat Pump
The swimming pool heat pump is one of the most economical ways of heating your swimming pool efficiently. Using the free renewable energy from the air, it is over 4/5 time more efficient than traditional heating. The swimming pool heat pump extends your swimming season and gives you comfort at high level. You could enjoy swimming not only in summer,but also in spring, autumn and even winter time.
ECO Friendly
The Heat Pump uses R410A Refrigerant which is ozone friendly dramatically reducing Carbon Emissions.
Titanium heat exchanger
The advanced titanium heat exchanger guarantees a longer life span, free of corrosion. It can be used with all types of water treatment including chlorine, iodine, bromine and salt water.
Multiple functions
- Cooling and heating functions available
- Auto operation, Auto-restart, Auto defrost
- Auto timer on/off:no human attendance is required
- Wide ambient working range: -10°C to 43°C
Reliable operation
The Heat Pump has several built in safety features, which include insufficient water flow protection, high/low pressure protection, overload protection, compressor protection.
Self-diagnosis
When there is malfunction,the swimming pool heat pump will make self-diagnosis by displaying error code on the control panel. To identify the problem, please refer to ERROR CODES pages in this manual.
SAFETY INSTRUCTIONS
To prevent injury to the user, other people or damage to property, the following instructions must be followed.
Install the unit only when it complies with local regulations, by-laws and standards. Check the main voltage and frequency. This unit must be earthed and have a supply voltage of 220 – 240V~/50Hz.
The following safety precautions should always be taken into account:
Page 3
-Be sure to read the following WARNING before installing the unit.
-After reading these instructions retain for future reference.
Installing the Unit.
Incorrect installation could cause injury due to fire, electric shock or water damage. If in doubt consult your local dealer or a qualified installer.
Securing the Unit.
The unit should be located on a solid, level, horizontal surface and securely fixed. Ensure free air-flow to all sides of the unit.
Electrical Connections.
Ensure the correct sized Circuit Breakers, isolators and cables are used. All terminals should be tightly secured and not prone to stress. This unit must be earthed.
Materials.
To prevent fire, electric shock and other hazards all materials should be suitable for the specific use of this unit.
Never use an extension cable to connect the unit to the electric power supply.
If there is no suitable earthed supply available, have one installed by a qualified electrician.
Do not move/repair the unit yourself.
Before carrying out any maintenance, service or repair work, the product must be isolated from the mains electrical supply. To prevent possible injury, only qualified engineers should carry out these works.
Do not install the unit in a place where there is a chance of flammable gas leaks. If there is a gas leak and gas accumulates in the area surrounding the unit, it could cause an explosion.
Water Connections.
All plumbing connections should be carried out as per the instructions in this manual. Failure to do so could result in water damage to property.
Cleaning the Unit.
To prevent injury always shut the power ‘OFF’ when cleaning or servicing the unit.
Error Codes.
If an error code occurs or you can smell burning, isolate the unit immediately and call your local installer.
Avoid contact with the fan when running as this will cause serious injury.
RENEWABLE HEATING & COOLING TECHNOLOGY
CAUT ION
WARNING
!
!
RENEWABLE HEATING & COOLING TECHNOLOGY
CONTENTS
Before starting the installation, please make sure that all ite ms a re f ou nd i nside the box.
The Unit Box
Item
Image
Qty
Swimming
pool
heat pump
1
Operation
and
Installation
Manual
1
Accessories
1(set)
Image
Qty
Item
Page 4
RENEWABLE HEATING & COOLING TECHNOLOGY
OVERVIEW OF THE UNIT
Page 5
LCSPI-120/150/170
Loading...
+ 14 hidden pages