ThermoSphere SCM-B-01, SCM-W-01 Installation Instructions

CONTROL | TOUCH
SINGLE MANUAL
SCM-W SCM-BINSTRUCTION GUIDE
Excellence in heating solutions.
Contents
Compatibility ..............................................................
What's in the box? .....................................................
Installing your thermostat ...........................................
Wiring diagram ...........................................................
User interface .............................................................
Settings ......................................................................
Technical data .............................................................
Factory reset & key lock ..............................................
3
4
5
6
10
13
14
16
17
2
Compatibility
This thermostat is compatible with ThermoSphere
NTC 10K oor sensor probes.
NTC 10kΩ @ 25°C
If you have an existing oor probe from another
thermostat that is not compatible, set your thermostat to ambient temperature sensing mode.
(Not advisable for timber or other temperature sensitive oors).
Replacing an existing thermostat? Contact the manufacturer's technical department
and ask for the rating of the oor sensor at 25°C.
3
What’s in the box?
Check you've got everything:
• Thermostat
Floor sensor probe (3m)
Floor sensor conduit (2m)
• Fixing screws
• Installation guide and warranty information
You will also need:
• Electrical screwdriver
• Deep electrical back box
• Electrical test meter
4
Before you start
Your thermostat should be:
Installed 1.2 - 1.5m from the oor
• On an internal wall
Outside any wet zones (IP30)
• Installed on an RCD protected circuit
Away from drafts or heat inuences
Installed so that the oor sensor probe can be laid in a
heated area of the oor
• Installed by a professional, in line with current electrical regulations and relevant local standards
5
Installing your thermostat
1. Switch off mains power
You will be installing your thermostat as part of a high voltage mains electrical circuit. To ensure your safety and to protect the thermostat, switch off the mains power and remove fuse from the spur before you start the installation.
ON ON ON ON ON
OFF
Fuse Box Fused Switch
6
!
CAUTION
High Voltage
Cables
OFF
Loading...