General Purpose and Chromatography Refrigerators
TSG Series
Installation and Operation
329137H01 Revision B August 2018
Page 2
IMPORTANT Read this instruction manual. Failure to follow the instructions in this manual can result in damage to the unit, injury to operating personnel, and poor equipment performance.
CAUTION All internal adjustments and maintenance must be performed by qualified service personnel.
© 2018 Thermo Fisher Scientific Inc. All rights reserved.
For your future reference and when contacting the factory, please have the following information readily available. It can be found on the dataplate attached to your unit.
Model Number:
Serial Number:
The following information, if available, is helpful for contacting the factory.
Date Purchased:
Purchase order number:
Source of Purchase:
(manufacturer or specific agent/rep organization)
Page 3

Contents

Model .......................................................................... 1
Safety Precautions....................................................... 2
Unpacking ................................................................... 4
Packing List ................................................................. 4
General Recommendations.......................................... 5
Temperature Monitoring ........................................... 5
Intended Use............................................................ 5
Initial Loading ........................................................... 5
Operating Standards.................................................... 6
Unit Specifications.................................................... 6
Installation.................................................................... 8
Location................................................................... 8
Leveling the Unit....................................................... 8
Castor Installing and Pallet Removal Instructions...... 8
Chromatography Refrigerators ................................. 10
Wiring....................................................................... 10
Shelves .................................................................... 13
Installation Instructions ............................................. 13
Door Operation ........................................................ 13
Remote Alarm .......................................................... 13
Final Checks ............................................................ 14
Startup......................................................................... 15
Initial Startup ............................................................ 15
Chromatography Refrigerators ................................. 15
Page 4
Product Loading and Unloading Guidelines.............. 15
Operation..................................................................... 16
Control Panel ........................................................... 16
Temperature Setpoint .............................................. 17
Alarms...................................................................... 17
Controller Parameter Settings................................... 18
Maintenance ................................................................ 21
Cleaning the Cabinet Interior .................................... 21
Cleaning the Unit (Chromatography Refrigerators) .... 21
Cleaning the Condenser........................................... 21
Automatic Defrost .................................................... 21
Gasket Maintenance ................................................ 21
Alarm Battery Maintenance ...................................... 21
Preparation for Storage ............................................ 22
Cleaning the Unit (Chromatography Refrigerators) .... 22
Replacing Sensor (Chromatography Refrigerators) ... 22 Sensor Maintenance
(Chromatography Refrigerators) ............................... 22
Troubleshooting........................................................... 23
End of Life Care ........................................................... 24
Warranty...................................................................... 25
Regulatory Compliance................................................ 26
Product Safety ......................................................... 26
Electromagnetic Compatibility .................................. 26
Energy Efficiency...................................................... 27
Additional Regulations and Markings........................ 27
Page 5

Model

The table below shows the units covered in this operation and installation manual by model number.
Figure 1. Applicable Models
Refrigerators
TSG12RPGA TSG45RSLA
TSG25RPGA TSG45CSLA
TSG25RPSA TSG49RPGA
TSG25RSGA TSG49CPGA
TSG25RSSA TSG49RPSA
TSG30RPGA TSG49RSGA
TSG30CPGA TSG49CSGA
TSG30RPSA TSG49RSSA
TSG30RSGA TSG72RPGA
TSG30CSGA TSG72CPGA
TSG30RSSA TSG72RSGA
TSG45RPLA TSG72CSGA
TSG45CPLA
The annotation of model numbers is given in the following table:
Table 1. Model Specification
Series TSG (Thermo Scientific)
Size (cu.ft) 12, 25, 30, 45, 49, 72
Type R = Refrigerator
C = Chromatography
Exterior P = Painted
S = Stainless
Door Type S = Solid
G = glass L = Sliding glass
Voltage A = 115 V / 60 Hz
General Purpose and Chromatography Refrigerators Model | 1
Page 6

Safety Precautions

In this manual, the following symbols and conventions are
.
used
WARNING: T indicates important operating instructions which reduce the risk of injury or poor performance of the unit.
WARNING: This symbol indicates potentially hazardous situations which, if not avoided, could result in serious injury or death.
WARNING: This symbol indicates situations where dangerous voltages exist and potential for electrical shock is present.
WARNING: This symbol indicates potentially hazardous situations, which if not avoided could result in fire.
CAUTION: This symbol, in the context of a CAUTION, indicates a potentially hazardous situation which if not avoided could result in minor to moderate injury or damage to the equipment. This indicates a situation which may result in property damage.
CAUTION: This symbol indicates surfaces which may become hot during use and may cause a burn if touched with unprotected body parts.
his symbol when used alone
Below are important safety precautions that apply to this pr
oduct.
CAUTION: Use this product only in the way described in the product literature and in this manual. Before using it, verify that this product is suitable for its intended use. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
CAUTION: Do not modify system components, especially the controller. Use OEM exact replacement equipment or parts. Before use, confirm that the product has not been altered in any way.
WARNING: Your unit must be properly grounded in conformity with national and local electrical codes. Do not connect the unit to overloaded power sources.
WARNING: Disconnect the unit from all power sources before cleaning, troubleshooting, or performing other maintenance on the product or its controls.
WARNING: This unit is not for storage of flammable materials.
WARNING: Before installing, using or maintaining this product, please be sure to read the manual and product warning labels carefully. Failure to follow these instructions may cause the product to malfunction, which could result in injury or damage.
CAUTION: This symbol indicates possible pinch points which may cause personal injury.
WARNING: The snowflake symbol indicates low temperatures and risk of frost bite. Do not touch bare metal or samples with unprotected body parts.
WARNING: Units are charged with hydrocarbon refrigerant (R290). Only qualified service personnel should service this unit.
WARNING: Unauthorized repair of your unit will invalidate your warranty. Contact Technical Service at 1-866-984-3766 for additional information.
DANGER: Risk of fire or explosion. Flammable refrigerant used to be repaired only by trained service personnel. Do not puncture refrigerant tubing.
WARNING: No equipment that uses an open flame should be placed inside the refrigerator. This will harm the unit, hamper functionality and compromise your safety.
CAUTION: Do not use any battery powered or externally-powered equipment in the refrigerator.
2 | Safety Precautions General Purpose and Chromatography Refrigerators
Page 7
Below are additional safety precautions that apply to chromatography refrigerator models:
CAUTION: Equipment should only be powered using the internal outlet. In case of a leak the safety circuit will remove power to the outlet in the unit, but shall have no control over equipment power via battery or externally. Do not use instrumentation or equipment that incorporates potential ignition sources, e.g. open contact switching, brushed DC and AC motors, etc.
CAUTION: The chromatography safety circuit has slots/holes at the bottom of the plug panel for enabling air to the safety sensor. Do not block the Safety Circuit ventilation holes as this will diminish and defeat the Safety Circuit.
WARNING: Do not store or use uncapped reagents, vessels and bottles inside the chromatography equipment. This may diminish functionality of the safety circuit.
General Purpose and Chromatography Refrigerators Safety Precautions | 3
Page 8

Unpacking

At delivery, examine the exterior for physical damage while the carrier’s representative is present. If exterior damage is present, carefully unpack and inspect the unit and all accessories for damage.
If there is no exterior damage, unpack and inspect the equipment within five days of delivery. If you find any damage, keep the packing materials and immediately report the damage to the carrier.
Do not return goods to the manufacturer without written authorization.
When submitting a claim for shipping damage, request that the carrier inspect the shipping container and equipment.

Packing List

Along with the unit, following things will be packed:
Installation and Operation manual is placed in the white envelope
Door Lock Key and Power Key Switch is wire tied to the pilaster on the upper top front.
Small bag with shelving clips
Shelves
Half shelves (with chromatography refrigerators)
Power cord (with chromatography refrigerators and 25, 30cf refrigerators)
Casters (Applicable for 12, 25, 30cf models only)
Wrench (Applicable for 12, 25, 30cf models only)
4 | Unpacking General Purpose and Chromatography Refrigerators
Page 9

General Recommendations

This section includes some general recommendations for your unit.

Temperature Monitoring

IMPORTANT NOTE: We recommend the use of a redundant and independent temperature monitoring system so that the unit can be monitored continuously for performance commensurate with the value of product stored.

Intended Use

The refrigerators described in this manual are lab-grade, general purpose units intended to store non-critical samples at operating temperatures between 2°C to10°C.
These units are not registered as medical devices or by a medical device regulatory body (e.g. FDA): that is, they have not been evaluated for the storage of samples for diagnostic use or for samples to be re-introduced to the body.
This unit is not intended for use in classified hazardous locations, nor to be used for the storage of flammable or corrosive inventory.
This refrigerators are not suitable for outdoor location.
CAUTION: Storage of unsealed corrosive substances may cause the interior of the unit to corrode.

Initial Loading

Allow the unit to operate at the desired temperature for a minimum of 12 hours before loading.
Load the unit one shelf at a time, starting from bottom to top shelf. After loading each shelf, allow the unit to recover to the desired set point before loading the next shelf. Repeat this process until the unit is fully loaded. Please refer to the section
Shelves for shelf load ratings.
CAUTION: Failure to follow these procedures or
overloading the unit may cause undue stress on the compressors or jeopardize user product safety.
General Purpose and Chromatography Refrigerators General Recommendations | 5
Page 10

Operating Standards

The units described in this manual are classified for use as stationary equipment in a Pollution Degree 2 and Over voltage Category II environment.
These units are designed to operate under the following environmental conditions:
Indoor use
Altitude up to 2000 m (6512 feet)
Maximum relative humidity 60% for temperatures from 15°C to 32°C (59°F to 90°F)
Main supply voltage fluctuations not to drop or exceed by 10% of the nominal voltage
Do not connect the unit to a GFCI (Ground Fault Circ Int
errupter) protected outlet as it may be subject
nu
isance tripping
Do not run this unit off the extension cords
uit
to

Unit Specifications

The data label is located on the left side on top towards front of the unit.
The specifications of refrigerator like voltage, required wall breaker amperage and power plug are same for all the units.
Voltage = 115 V/60 Hz Breaker Amps = 15 A Chromatography Power Plug = NEMA 5-15P General Purpose Refrigerator Power Plug = NEMA 5-15P This plug must be plugged into/supplied with it's own
individual branch circuit.
CAUTION: Chromatography units are supplied with two separate power cords. Be careful to unplug both during movement, testing or repair of the product.
Other specifications are listed in the table below.
Table 2. Unit Specifications
Unit Size
(Cu.ft.)
TSG12RPGA 12 Painted Glass 4
TSG25RPGA 25 Painted Glass 4
TSG25RPSA 25 Painted Solid 4
TSG25RSGA 25
TSG25RSSA 25
TSG30RPGA 30 Painted Glass 4
TSG30CPGA 30 Painted Glass
TSG30RPSA 30 Painted Solid 4
Exterior Door
Typ e
Stainless Steel
Stainless Steel
Glass 4
Solid 4
No.of Shelves
4 + 3 Half Shelves
Exterior Dimensions (H x W x D)
1925.9 x 628.6 x 635.0 mm (75.82 x 24.75 x 25.00 in)
2057.1 x 704.8 x 812.8 mm (81.00 x 27.75 x 32.00 in)
2057.1 x 704.8 x 812.8 mm (81.00 x 27.75 x 32.00 in)
2057.1 x 704.8 x 812.8 mm (81.00 x 27.75 x 32.00 in)
2057.1 x 704.8 x 812.8 mm (81.00 x 27.75 x 32.00 in)
2057.1 x 781.0 x 812.8 mm (81.00 x 30.75 x 32.00 in)
2057.1 x 781.0 x 812.8 mm (81.00 x 30.75 x 32.00 in)
2057.1 x 781.0 x 812.8 mm (81.00 x 30.75 x 32.00 in)
6 | Operating Standards General Purpose and Chromatography Refrigerators
Page 11
Table 2. Unit Specifications
Unit Size
(Cu.ft.)
TSG30RSGA 30
TSG30CSGA 30
TSG30RSSA 30
TSG45RPLA 45 Painted
TSG45CPLA 45 Painted
TSG45RSLA 45
TSG45CSLA 45
TSG49RPGA 49 Painted Glass 8
Exterior Door
Typ e
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Glass 4
Glass
Solid 4
Sliding Glass
Sliding Glass
Sliding Glass
Sliding Glass
No.of Shelves
4 + 3 Half Shelves
8
8 + 2 Half Shelves
8
8 + 2 Half Shelves
Exterior Dimensions (H x W x D)
2057.1 x 781.0 x 812.8 mm (81.00 x 30.75 x 32.00 in)
2057.1 x 781.0 x 812.8 mm (81.00 x 30.75 x 32.00 in)
2057.1 x 781.0 x 812.8 mm (81.00 x 30.75 x 32.00 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
TSG49CPGA 49 Painted Glass
TSG49RPSA 49 Painted Solid 8
TSG49RSGA 49
TSG49CSGA 49
TSG49RSSA 49
TSG72RPGA 72 Painted Glass 12
TSG72CPGA 72 Painted Glass
TSG72RSGA 72
TSG72CSGA 72
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Glass 8
Glass
Solid 8
Glass 12
Glass
8 + 2 Half Shelves
8 + 2 Half Shelves
12+ 2 Half Shelves
12+ 2 Half Shelves
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1338.6 x 812.8 mm (81.0 x 52.7 x 32.0 in)
2057.1 x 1924.0 x 812.8 mm (81.00 x 75.75 x 32.00 in)
2057.1 x 1924.0 x 812.8 mm (81.00 x 75.75 x 32.00 in)
2057.1 x 1924.0 x 812.8 mm (81.00 x 75.75 x 32.00 in)
2057.1 x 1924.0 x 812.8 mm (81.00 x 75.75 x 32.00 in)
General Purpose and Chromatography Refrigerators Operating Standards | 7
Page 12

Installation

ARNING: Do not exceed the electrical rating
W
printed on the data plate located on the upper left side of the unit.

Location

Install the unit on a level area free from vibration with minimum 3 inches of clearance on all sides and 4 inches on top. Do not position the equipment in direct sunlight or near heating diffusers, radiators, or other sources of heat.
Note: Do not move the unit in fully loaded condition.

Leveling the Unit

The refrigerator must be level in order to provide adequate condensation drainage as well as proper door alignment and operation. The refrigerator should be in its final operating location and set so that it is firmly positioned on the floor. Level the cabinet front to rear and side-to-side using the corner leveling screws. The front leveling screws are accessed by removing the base grill, as described below:
1. Remove the lower grill attachment screws
2. Grasp the grill with both hands
3. Lift the grill approximately 1/2"
4. Pull grill away from the refrigerator
Without Forklift
Required Tools: Phillips head screwdriver, 7/16” and 3/8” wrenches, and a minimum of 2 people.
All the units are shipped with factory installed feet with rolling casters supplied inside of the unit. The following instructions demonstrate how to remove the cabinet from its shipping base (pallet) and install the casters without use of a forklift.
Note: The unit should be unpacked near the desired final location.
1. Remove the packaging and kick plates from unit Rem
ove additional packaging to access the interior of th
ca
binet. Be sure to keep one cardboard corner fo
sequent step.
sub
.
r
e
2. Using a screwdriver, remove the screws holding on th

Castor Installing and Pallet Removal Instructions

CAUTION: Avoid damage to the refrigerant tubing which may cause a refrigerant leak while handling, moving, and operating this unit.
Note: Casters available for 12, 25, and 30 cu. ft. units; leveling feet only on 45, 49, and 72 cu. ft. units
8 | Installation General Purpose and Chromatography Refrigerators
front grill re
3. Remove bolts (4) holding the unit to the pallet using the 7/16” wrench.
Note: From this step onward, a minimum of 2 people are required. Use additional people if necessary.
4. With one person on each side, gently slide the un to
. Lift grill upwards and pull away from unit
move. Set aside.
wards the side edge of the pallet. Slide the unit so th
e
to
it
at
Page 13
there are approximately 3 inches of overhang to allow the removal of the factory installed feet and installation of the casters.
7. Gently rotate unit to install the last caster.
Person 2: Continue supporting the unit at the floor end. Person 1: Install 1 caster on the front of unit. Tighten
using caster wrench supplied.
CAUTION: Two people are always required to move the unit. Never move or adjust unit when some one is working on the unit (i.e. adjusting casters).
5. Person 1: Remain standing on the side of the pallet and providing additional unit support. Person 2: Remove all 4 factory installed feet (using the 3/8” wrench to loosen if necessary). Install 2 casters on the overhang edge. Tighten using caster wrench supplied.
Note: Some casters lock and others do not. It is recommended to install the locking casters on the front of the unit.
6. While supporting the unit, carefully slide the unit until the casters reach the ground. Gently slide the back edge off of the pallet approximately 3 inches to allow for installation of the back caster. Person 2: Continue supporting the unit at the floor end. Person 1: Install 1 caster on the back of the unit. Tighten using caster wrench supplied.
8. Take a cardboard packaging corner, fold in half, and place under the pallet/unit with the fold away from the pallet. Gently position unit parallel with the pallet using the edge of the unit to support the pallet. Once in position, gently roll the unit off of the pallet.
With Forklift
Required Tools: Phillips Head Screwdriver, 7/16” and 3/8” Wrenches, and a minimum of 2 people.
The following instructions demonstrate how to remove the cabinet from its shipping base (pallet) and install the casters or lower legs using a fork truck.
1. Remove the screws, bolts and caster by following the instructions given in section Without Forklift.
Note: Always use caution when lifting unit with forklift to ensure not to damage or drop unit.
General Purpose and Chromatography Refrigerators Installation | 9
Page 14
2. Carefully position forks to lift unit from rear. Ensure unit is fully positioned on fork truck prior to raising the forks.
3. Raise the unit approximately six inches to allow access to the feet and casters. Person 1: Stand at the front of the unit and provide additional support to the unit. Person 2: If feet are desired, lower all 4 factory installed feet (using the 3/8” wrench to loosen if necessary). If rolling casters are desired, remove the feet and install the 4 casters and tighten using caster wrench supplied.
Note: Some casters lock and others do not. It is advised to install the locking casters on the front of the unit.
The outlet assembly has two LEDs:
RED (on the top) - When the red LED is ON, it indicates there is no power to the AC outlet inside the unit.
GREEN (on the bottom) - When the green LED is ON, it indicates there is power to the AC outlet inside the unit.
4. Remove pallet from below the unit and gently lower unit in desired location.

Chromatography Refrigerators

The chromatography refrigerator is equipped with a safety circuit. In the event the safety circuit is tripped (the safety sensor senses a flammable gas), the power to the internal outlet will be discontinued and the user will need to manually reset the safety circuit assembly using the reset switch at the right side of header panel before power is restored. To do this, toggle the switch located on the top right side of the header panel beside the remote alarm contacts. There will be a power delay to the outlet for approximately 4 minutes where the red LED will be illuminated.
When power is available at the outlet, the red LED will turn off and the green LED will illuminate.
If the circuit trips from RED back to GREEN repeatedly or never turns GREEN, please contact Customer Service.
Flammable materials should not be stored in the refrigerator.
Lights
The GFCI outlet assembly is located inside the unit back in the center.
Switches
The Chromatography refrigerators has a reset switch on the right side of the header panel, above remote alarm contacts.
Chromatography Manual Reset: This is used to manually reset the safety circuit in the AC receptacle assembly after the LED turns RED from GREEN due to a safety trip event which disengages power to outlet inside the refrigerator. It is present on the right side top front corner next to the remote alarm contacts.

Wiring

The wiring diagram for the units is shown in Figure 2.
CAUTION: Connect the equipment to the
correct power source. Incorrect voltage can result in severe damage to the equipment.
CAUTION: For personal safety and trouble-free operation, this unit must be properly grounded while in use. Failure to ground the equipment may cause personal injury or damage to the equipment. Always conform to the National Electrical Code and local codes. Do not connect the unit to overloaded power lines.
10 | Installation General Purpose and Chromatography Refrigerators
Page 15
CAUTION: Always connect the unit to a dedicated (separate) circuit. Each unit is equipped with a service cord and plug designed to connect it to a power outlet which delivers the correct voltage. Supply voltage must be within ±10% of the unit rated voltage. If cord becomes damaged, replace with a properly rated power supply cord. Power Cord Specifications: 3-G 12 AWG, NEMA 5-15 P, 15A / 125V.
CAUTION: Never cut the grounding prong from the service cord plug. If the prong is removed, the warranty is invalidated.
CAUTION: Disconnect the power cord in case of emergency.
General Purpose and Chromatography Refrigerators Installation | 11
Page 16
6&


:+,7(
%/$&.
%52:1
1'(9$3)$121
/$5*(581,7621/<
(9$3)$1
:+,7(
 
6 6
',
6
6
'$1)266&21752//(5'(7$,/
&2035(6625
5(027($/$50
/,1(
1(875$/
/,*+7
$,56(1625
(9$36(1625
5&581&$3$&,725
6&67$57&$3$&,725
2/29(5/2$'
'$1)266&21752//(57(50,1$/
&211(&7,2132,17
&5&21752/5(/$<
/(*(1'
6((&21752//(5'(7$,/
5(027($/$50&217$&76
12&201&

5(/$<
:+,7(
&2035(6625'(7$,/93+
&855(175(/$<
6
0
&21'(16(5)$1
&
6
5
&203
2/
/$03
/('/$03
32:(5
6833/<
6((&21752//(5'(7$,/
6((&21752//(5'(7$,/
6((&21752//(5'(7$,/
-
-
-
52&.(5
6:,7&+
-

$&287/(7
5(/$<

'&,1
-
+&6(1625
%2$5'


*5((1
/('
5('
/('
32:(56833/<
6,*1$/
&21',7,21,1*
%2$5'
.(<6:


1&
&20
&2,/
5(/$<
)250&
.(<6:
9
%$77(5<
%8==(5
/('



%/$&.
%/8(
<(//2:
%/$&.
%/$&.
%/$&.
5('
%52:1
%/$&.
%52:1
:+,7(
%/8(
%/8(
%52:1
%/8(
%52:1
%/$&.
%/$&.
%/$&.
%/$&.
%52:1
%/8(
%/$&.
*5((1
:+,7(
*5$<
%/$&.
5('
5('
&+520$72*5$3+<5()5,*(5$725621/<
%/$&.
:+,7(
%52:1
%/8(:+,7(
%52:1
%/$&.
*5((1
<(//2:
:+,7(
5('
:+,7(
*5((1
*5((1
*5((1
5('
%/$&.
*5((1
<(//2:
%/8(
:+,7(

*5((1
<(//2:
(0,
),/7(5
(0,),/7(521/<
)25&)&)
5()5,*(5$7256
Figure 2. Wiring Diagram
12 | Installation General Purpose and Chromatography Refrigerators
Page 17

Shelves

2. Insert top of the clip into the desired hole of the pilaster the retaining tab should be facing upward
s.
All the units come standard with wire shelves. Each unit has different number of shelves. Refer to Ta b le 2 for more information.
Maximum shelf capacity is 45 kg (100 lbs) for full shelves and
22.5 kg (50 lbs) for half shelves. For safety in shipping, the shelves are packaged and secured
inside the cabinet. Insert the shelf support hangers (included with the manual inside the unit) into the built-in shelf supports (located on the inside walls of the cabinet interior) at the desired locations.
3.
Rotate the clip downwards and insert the bottom tab in the
appropriate hole, the clip may be squeezes slight
du
ring installation
4.
Install shelves onto clips with the product retention bar facing upwards, be careful not to is lodge clips during shelve instal
5.
Prior to loading the shelf, ensure that the shelf is restin
each of 4 clips and the clips are installed.
on
CAUTION: Improper shelf clip installation may cause shelf and/or product damage to the unit.
CAUTION: Do not overload the shelves, the unit is designed to utilize all shelves that are supplied in an equally spaced manner.
.
lation.
to
ly
g

Door Operation

The swinging door units are designed to stay open if opened 90 degrees or more. The door spring tension cannot be adjusted.
Figure 3. Shelf Arrangement
Figure 4. Shelf Clip

Installation Instructions

WARNING: Do not to move this unit while loaded
The Sliding doors can be opened completely towards left or right. If the self-closing door does not work properly, make sure the unit is leveled properly
Door Seal
CAUTION: Door seal integrity is critical for unit performance. A loose fitting gasket allows moist air to be drawn into the cabinet, resulting in quicker frost buildup on the cabinet walls, longer running time, poor temperature maintenance and increased operation cost.

Remote Alarm

All units have factory-installed remote alarm contacts that can be used for remote alarm systems. The maximum distance between a unit and a remote alarm depends on the wire gauge used. Refer to Ta bl e 4 below:
The Remote alarm contacts are located on the right side of the header panel. The three terminals are: COMMON, OPEN ON FAIL (Normally Closed) and CLOSE ON FAIL (Normally Open).
1. Determine proper location for shelves clips, the reference number on the pilaster can serve as a guide to ensu clips
are properly located.
General Purpose and Chromatography Refrigerators Installation | 13
re all
Page 18
Table 3. Wire Gauge and Distance to Remote Alarm
Wire Gauge
20 530 265
18 840 420
16 1330 665
14 2120 1060
12 3370 1685
To install the remote alarm, make the following connections:
1. Connect the COMMON terminal on the cabinet switch to the COMMON wire on the alarm.
2. To get an alarm when the switch contacts open, connec th ON
3. To get an alarm when the switch contacts close, connec th CLOSE ON FAIL wire on the alarm. The COMMON and CLOSE ON FAIL wires must be tied together in th application
Tot al Wi re Length (feet)
e OPEN ON FAIL terminal on the cabinet to the
FAIL wire on the alarm.
e CLOSE ON FAIL terminal on the cabinet to the
Distance to Alarm 1/2 Wire Length (feet)
OPEN
is
t
t
4.
Plug the alarm system service cord in ou
.
tlet
5.
The contacts will trip in the event of high temperatur a
larm or low temperature alarm.
to an electrical
e

Final Checks

Before start up, be sure to complete the following steps:
1. Make sure that the unit is free of all wood or cardboar ship
ping materials, both inside and outside.
2. Check the positions of the shelves. If you want to adju the posi
3. Verify that the unit is connected to a dedicated circuit.
tions.
d
st
14 | Installation General Purpose and Chromatography Refrigerators
Page 19

Startup

Initial Startup

To start up the unit, complete the following steps:
1. Connect the AC main power cord. The evaporator fans start when the power cord is plugged in.
2. Insert the silver colored key in the switch and turn to t Po
wer On position.
3. Allow the unit to reach operating temperature before loading it with any product. To stabilize the temperature profile, a 24-hour waiting period is recommended.
4. If you desire to enable the power failure alarm, turn the three position key switch one turn further clockwise to the All Alarm On position
5.
If you have a remote alarm, hook it up at this point (refer to section Remote Alarm).
6. If desired, lock the cabinet door using the silver colore ke
y. Place duplicate key copies in a safe place.
All controls should now be fully operational, the alarm active (if enabled), and all visual indicators active.
.
he
d
Operating equipment inside the refrigerator may shift the temperature profile in the unit. Monitor the refrigerator as needed for any such shift.

Product Loading and Unloading Guidelines

When loading your unit, take care to observe the following guidelines:
Distribute the load as evenly as possible. Temperature uniformity depends on air circulation, which could be impeded if the internal storage components are overfilled, particularly at the top of the cabine
For critical applications, be sure that the alarm system
e working and active before you load any product.
ar
Ensure clearance between the top of the cargo and the bottom of the internal storage components. Lack of clearance may affect unit performance or impede operation of the storage component.
t.
s

Chromatography Refrigerators

1. Connect the AC main power cord.
2. Connect the GFCI AC power cord.
3. Make sure the reset switch is in ON position.
4. Insert the silver colored key in the switch and turn to t Power On pos
abinet temperature.
c
Note: The Chromatography refrigerator is shipped with the manual reset switch at the top right side front of the header panel above the remote alarm contacts (refer to section Switches) as ON. The Manual reset switch should always be in ON position.
5. The red LED on the chromatography safety circuit turn ON.
6
. After a power delay of 4 minutes the red LED on the
chromatography safety circuit turns Off and the gree
n the chromatography safety circuit turns ON.
LED o
Note: During initial power-up, the GFCI outlet will not be powered until after an approximate 4 minute delay.
ition. The display will show the
actual
he
s
n
General Purpose and Chromatography Refrigerators Startup | 15
Page 20

Operation

Control Panel

Figure 5. Control Panel
1. Display: During normal operation, the display shows ca
binet temperature in degree Celsius as measured
th
e primary sensor. When Alarm and Compressor are
active, the respective LED’s will be displayed. Refe
ble below for LED display symbols. A display code will
ta also be visible during the functioning based on the type
rm.
ala
r to the
Defrost LED Alarm LED Compressor LED
On Fixed: Defrost Active
Off: Defrost Off
On Fixed: Alarm Present
Flashing: Alarm Silenced
Off: No Alarm
On Fixed: Compressor Active
Flashing: Delay, Protection or Activation Blocked
Off: No Alarm
by
3. SC: This button is used to turn the cabinet LED light on and off with a single touch. This button is also used fo selecting an
4. Up: Scrolls the menu items and increases the values.
of
5. Down: Scrolls the menu items and decrease the values.
6. Power Fail LED: This LED indicates the powe
tion in the unit.The flash light indicate power failur
situa situation.
7. Key Switch: Use power failure alarm on an
Note: This is not a primary disconnect device, thus even if the key switch is Off the fan will be On as it is Pl
ease remove the power cord to completely turn Off the
unit.
8. Off: Turns the power to the controller off.
9. Power On: Turns On power to the controller and used to
silence the power failure alarm.
10. All Alarm ON: Turns On the audible power fail alarm.
option in parameters.
d to turn the power to the controller and
d off.
r
r failure
e
hard wired.
as
2. Defrost: This button is used to manually defrost the unit as well as to go back from the parameter settings.
16 | Operation General Purpose and Chromatography Refrigerators
Page 21

Temperature Setpoint

The factory default temperature setpoint is 5°C for all laboratory refrigerators. Adjusting the setpoint is not recommended. In case the setpoint has to be changed, follow the instructions given below.
The display shows the current temperature.
Press Up / Down button to increase / decrease setpoint temperature.
After 30 seconds, the display automatically reverts to the current temperature.

Alarms

The alarm system is designed to provide visual and audible warning signals for both power failure and rise in temperature. The alarm is equipped with a battery backup.
The power failure alarm system is activated only when the key switch is turned to the Power Failure Alarm ON position.
Low temperature, high temperature and door ajar alarms are set to ON position by default as soon as the controller is turned on. These cannot be turned off.
Default low and high alarm values are 2°C and 10°C. These values may be adjusted, following instructions in section
Temperature Setpoint. Note: There is no door open alarm on sliding door model.
The audible warning signal sounds when there is a power failure, temperature alarm condition, or when the door is ajar for more than 1 minute.
Alarm display codes for high temperature, low temperature, sensor failure, door ajar are mentioned in Ta bl e 5 .
Table 4. Alarm Codes
Alarm code
“Hi” Air temperature is
“Lo” Air temperature is
“dor” Door open for more
“E01” “S1” error Always Blink “E01”. If configured: cut in
Trigger Automatic
clearance
User Configured Blink “Hi” with the highest higher than “ALA­>Hat” for “ALA­>Htd”
User Configured Blink “Lo” with the lowest less than “LAt” for “Ltd”
Always Blink “dor”. If configured: cut in than “ALA->dod”
Outputs Comments
temperature; If configured: cut in alarm relay, beep the buzzer
temperature; If configured: cut in alarm relay, beep the buzzer
alarm relay, beep the buzzer
alarm relay, beep the buzzer
High temperature alarm
Low temperature alarm
Door open alarm
“S1” sensor failure = (short or open)
“E02” “S2” error Always Blink “E02”. If configured: cut in
alarm relay, beep the buzzer
General Purpose and Chromatography Refrigerators Operation | 17
“S2” sensor failure = (short or open)
Page 22
Alarm Silencing
Password Protection
To mute the power fail alarm, change the key-switch to Power ON position. The power fail alarm will not be audible but the Red LED will be displayed on the control panel.
The high temperature, low temperature, sensor failure and door ajar alarms can be silenced by pressing any key on the controller.
When the alarm is active, the alarm code flashes alternately with the temperature and the alarm symbol.
Once the alarm is silenced, the code stops flashing but the temperature and the alarm symbol is still displayed.
The unit is password protected except the setpoint which can be adjusted without the password. The default password is 0.
To change the parameters, password is required to be entered.
1. Hold “Up / Down” button for 5 seconds.
2. The display will show “PAS” after which brief anges to 000.
ch
3. Press SC to confirm.
You have now entered the controller parameters menu.
To change the password, you need to go to parameter settings.
1. Enter the current password as given above and get to the
menu.
2. Scroll down to “ASi” group.
3. Press “SC” button to confirm.
4. Scroll to “PS1” parameter and Press “SC” button to
confirm.
5. Scroll “Up / Down” buttons to enter the desired
password.
delay
6. Press “SC” button to confirm.
Controller Parameter
After 30 seconds, the display automatically reverts to showing the current temperature. If this does not happen, press the Defrost button twice.
Settings
To access the controller settings you need to enter the password and the access level will determine which parameter you can view and edit.
Table 5. Parameter List
Category Abv Description All Single
Doors
tHE Thermostat settings
SEt Set Point 5°C 5°C 5°C
SPr Set Point Adjustment Ratio 0.2°C 0°C 0°C
diF Differential 1.1°C 1.1°C 1.1°C
HSE High Set Point 6°C 6°C 6°C
All Sliding Doors
All Double and Triple Door Models
LSE Low Set point 2°C 2°C 2°C
dEF Defrost Settings
dFt Def. Type nAt nAt nAt
18 | Operation General Purpose and Chromatography Refrigerators
Page 23
Table 5. Parameter List
Category Abv Description All Single
Doors
Add Adaptive Defrost Yes Yes Yes
dtt Def Terminate Temp 4°C 4°C 4°C
drt Def Reset Temp 2°C 2°C 2°C
dii Def Min Interval 1 hour 1 hour 1 hour
dAi Def Max Interval 1 hour 1 hour 1 hour
dit Def Min Time 5 min 5 min 5 min
dAt Def Max Time 30 min 30 min 30 min
dot Drip Off Time 0 min 0 min 0 min
fdd Fan Delay After Defrost 0 sec 0 sec 0 sec
ftd Fan Start Temp 10°C 10°C 10°C
dFa Defrost Fan On Yes Yes Yes
dCt Defrost On Compressor Time No No No
doC Defrost by Comp. Running Time 1 hour 1 hour 1 hour
All Sliding Doors
All Double and Triple Door Models
dEt Defrost Start Evaporator Temp 0°C 0°C 0°C
ddt Defrost Delta T 3.0 k 3.0 k 3.0 k
idi Initial Defrost Interval 0 hour 0 hour 0 hour
idd Initial Defrost Duration 0 cycle 0 cycle 0 cycle
CoP Compressor Settings
uPt Voltage Protection No No No
uLi Minimum Cut-in Voltage 0 VAC 0 VAC 0 VAC
uLo Minimum Cut-out Voltage 0 VAC 0 VAC 0 VAC
uHi Maximum Voltage 270 VAC 270 VAC 270 VAC
EHd Sensor Error Type SEt SEt SEt
Ert Error Run Time 10 min 10 min 10 min
ESt Error Stop Time 7 min 7 min 7 min
CSt Min Stop Time 2 min 2 min 2 min
crt Min Run Time 2 min 2 min 2 min
Cot Max Off Time 0 min 0 min 0 min
Cdd Compressor Door Open Delay 0 min 0 min 0 min
Srt System Resume After Door Open 0 min 0 min 0 min
Pod Power On Delay 60 sec 60 sec 60 sec
General Purpose and Chromatography Refrigerators Operation | 19
Page 24
Table 5. Parameter List
Category Abv Description All Single
Doors
Pot Power ON Temperature 16°C 16°C 16°C
diS Display Settings
diC Display Intensity Auto Control No No No
din Display Intensity 8 8 8
CFu Display Unit C C C
trS Temp Sensor to Display Sco Sco Sco
rES Display Resolution 1 1 1
rLT Display Range Limit No No No
ddL Display Delay 1 min 1 min 1 min
doF Display Offset 0.0 K 0.0 K 0.0 K
dLt Lock-Time After Defrost 15 min 15 min 15 min
SEC Show Economy/Night Mode No No No
SHo Show Holiday No No No
All Sliding Doors
All Double and Triple Door Models
Sdf Show Defrost No No No
SCS Show Compressor Symbol Yes Yes Yes
SFS Show Fan Symbol No No No
SdS Show Defrost Symbol No No No
SES Show ECO Symbol No No No
idP Info Menu Display Item 15 15 15
SSC Show Pull Down No No No
ALA Alarm Settings
HAt High Temp Alarm 10°C 10°C 10°C
LAt Low Temp Alarm 2°C 2°C 2°C
Htd High Alarm Delay 0 min 0 min 0 min
Ltd Low Alarm Delay 0 min 0 min 0min
dod Door Open Delay 1 min 1 min* 1 min
ACA Auto Clearance of Alarm Yes Yes No
Note: *45 cu. ft. sliding door models do not have door ajar alarms.
20 | Operation General Purpose and Chromatography Refrigerators
Page 25

Maintenance

Cleaning the Cabinet Interior

WARNING: Disconnect equipment from main power before attempting any maintenance to equipment or its controls unless stated otherwise.
To clean the cabinet interior, remove the shelves, use a solution of water and a mild detergent for cleaning. Rinse the interior storage components and wipe them dry with a soft cloth.

Cleaning the Unit (Chromatography Refrigerators)

Use a solution of water and a mild detergent for cleaning. Lightly spray the interior storage components and wipe them dry with a soft cloth or spray the cloth first and then wipe interior surfaces.
Do not spray or pour directly into holes and gaps in the chromatography safety circuit assembly for cleaning. Use a wet wipe to clean around sensor box and outlet.
If the sensor led turns red after cleaning, manually reset the safety circuit assembly using the manual reset switch at the back of the unit.
1. Disconnect the power.
2. Vacuum the condenser and clean up any loose dust.
3. Reconnect power.

Automatic Defrost

The defrosting process on all the models is primarily accomplished by air circulated during off-cycle. This heat free process ensures that the temperature is not affected by the defrost cycle. Defrost cycle works on adaptive defrost method which is both temperature and time controlled.
When the evaporator sensor reaches below 0°C, the defrost cycle will be initiated. Initially the defrost cycle continues for a minimum duration of 5 minutes and after that the defrost cycle will be terminated once the evaporator sensor temperature reaches 4°C. In case the evaporator sensor doesn’t reach the temperature of 4°C within 30 minutes from the start of defrost cycle, the defrost cycle will be terminated.

Gasket Maintenance

Periodically check the gaskets around the door for punctures or tears. Leaks are indicated by condensation or frost which form at the point of gasket failure. Make sure that the cabinet is level.
Keep the door gaskets clean and frost free by wiping gently with a soft cloth.
To check the door seal, complete the following steps:
1. Open the door
2. Insert a strip of paper (a couple of inches wide) between

Cleaning the Condenser

CAUTION: Condensers should be cleaned at least every six months; more often if the laboratory area is dusty. In heavy traffic areas, condensers load with dirt more quickly. Failure to keep the condenser clean can result in equipment warm-up or erratic temperatures.
CAUTION: Never clean around the condensers with your fingers. Some surfaces are sharp.
the door gasket and the cabinet flange and close the door.
3. Slowly pull the paper strip from the outside. You shou
f
eel some resistance.
4. Repeat this test at 4-inch intervals around the door. If th
do
or does no seal properly, replace the gasket.
Alarm Battery
ld
Maintenance
The condenser is located in the bottom front of the unit. To clean the condenser, complete the following steps:
General Purpose and Chromatography Refrigerators Maintenance | 21
Unit comes with (4) AA Alkaline 1.5 V batteries. The back-up time for the alarm battery system is 60 hours. Battery must be
e
Page 26
replaced after an active alarm or after every 12 months, whichever is the earliest.
Cleaning the Unit
Steps to follow for battery replacement:
1. Locate the knurled/thumb screw on the left side of the he
ader panel.
2. Remove the knurled/thumb screw by hand.
(Chromatography Refrigerators)
Use a solution of water and a mild detergent for cleaning. Lightly spray the interior storage components and wipe them dry with a soft cloth or spray the cloth first and then wipe interior surfaces.
Do not spray or pour directly into holes and gaps in the chromatography safety circuit assembly for cleaning. Use a wet wipe to clean around sensor box and outlet.
If the sensor led turns red after cleaning, manually reset the safety circuit assembly using the manual reset switch on the right side of header panel.

Replacing Sensor (Chromatography Refrigerators)

3.
Once the screws are removed, wear hand gloves and gently pull the bracket out until you see the batterie completely.
4.
Replace the batteries and gently close the bracket. Once the bracket is closed, Align the holes on the bracket and header panel, screw using the knurled/thumb screw.
s

Preparation for Storage

If the unit is going to be stored in an off condition, allow the unit to warm up and dry out with the door open before moving into storage.
The sensor needs replacement if the temperature goes below freezing in the cabinet. Use system alarms to ensure the temperature inside the unit is always above 0°C. If exposed to freezing conditions the sensor should be replaced.
If the display shows an error and sounds an alarm (in case of a control, defrost, bottle or ambient probe failure), the sensor needs to be replaced.

Sensor Maintenance (Chromatography Refrigerators)

The sensor should be replaced every five years by a trained service provider.
22 | Maintenance General Purpose and Chromatography Refrigerators
Page 27

Troubleshooting

WARNING: Troubleshooting procedures involve working with high voltages which can cause injury or death. Troubleshooting should only be performed by Factory Authorized Service Personnel.
This section is a guide for troubleshooting equipment problems. Component parts must be replaced only with like components.
Table 6. Troubleshooting Procedure
Problem Cause Solution
Power supply
Unit does not operate or power failure indicator is on
Unit overloaded
Unit runs continuously Dirty condenser Clean condenser
Control setting too high Reset control
Space temperature too high
Inadequate air circulation Improve air movement
Temperature control Make sure that the control is set correctly.
Temperature fluctuates/ insufficient cooling
The equipment makes too much noise
Refrigerator freezing Temperature control Reset control
Condenser clogged Make sure the condenser is clean.
Other causes
The equipment is not level
Door is open Make sure the door is completely closed.
Check that the cord is securely plugged in. Plug another appliance into the outlet to see if it is live.
Test the voltage and verify that it is correct for your unit Check if there is any frost build up on refrigeration coils. Turn unit off and allow it to defrost. Remove contents from top shelf of unit.
If the temperature control is set correctly, the condenser is clean, but temperature continues to fluctuate, call an authorized service representative.
Place the equipment on an even surface or use adjustable feet.
Door seal check Check the door seal
Warm product recently loaded in unit
Unit warms up
Unit noisy Loose parts or mountings Find and tighten
General Purpose and Chromatography Refrigerators Troubleshooting | 23
Power supply
Compressor not functioning
Allow ample time to recover from loading warm product.
Check for proper voltage to the unit. If there is no voltage to the unit, call an electrician.
If the compressor is not running and the power audible is on, have an electrician check for proper voltage to the unit.
If the compressor is not running and the power failure alarm is off, call the customer service for assistance.
Page 28

End of Life Care

Be sure to follow local regulations when disposing of an old unit. Some suggestions are listed below:
1. Remove items and defrost unit. Be sure to clean up an biological
2. Remove the cabinet door to help prevent entrapment inside of a unit.
3. Have a certified technician remove the refrigerant and compressor, then drain the compressor and oil from th system. Dispose of
gulations.
re
safety hazards.
components foll
owing local
y
e
24 | End of Life Care General Purpose and Chromatography Refrigerators
Page 29

Warranty

Domestic Warranty • 24 Months Parts and Labor, 5 years for compressor International Warranty • 24 Months Full Warranty Parts During the first twenty four (24) months from shipment, Thermo Fisher Scientific Inc, through its authorized Dealer or service
organizations, will at its option and expense repair or replace any part found to be non-conforming in material or workmanship. Thermo Fisher Scientific Inc reserves the right to use replacement parts, which are used or reconditioned. Replacement or repaired parts will be warranted for only the unexpired portion of the original warranty.
This warranty does not apply to damage caused by (i) accident, misuse, fire, flood or acts of God; (ii) failure to properly install, operate or maintain the products in accordance with the printed instructions provided, (iii) causes external to the products such as, but not limited to, power failure or electrical power surges, (iv) improper storage and handling of the products, (v) use of the products in combination with equipment or software not supplied by Thermo Fisher; or (vi) installation, maintenance, repair, service, relocation or alteration of the products by any person other than Thermo Fisher or its authorized representative. To obtain proper warranty service, you must contact the nearest authorized service center or Dealer. Thermo Fisher Scientific, Inc’s own shipping records showing date of shipment shall be conclusive in establishing the warranty period. At Thermo Fisher’s option, all nonconforming parts must be returned to Thermo Fisher postage paid and replacement parts are shipped FOB Thermo Fisher’s location.
Limitation of Liability: THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL, OR IMPLIED. NO
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY. THERMO FISHER DOES NOT WARRANT THAT THE PRODUCTS ARE ERROR-FREE OR WILL ACCOMPLISH ANY PARTICULAR RESULT.
THERMO FISHER SHALL NOT BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING, WITHOUT IMITATION, DAMAGES TO LOST PROFITS OR LOSS OF PRODUCTS.
General Purpose and Chromatography Refrigerators Warranty | 25
Page 30

Regulatory Compliance

Product Safety

Product Testing
This product family has been tested to applicable product safety standards by Underwriters Laboratories (UL), which is a Nationally Recognized Test Laboratory (NRTL).
Hydrocarbon Refrigerants
According to U.S. Code of Federal Regulation 40 Part 82, this refrigerator employs the natural hydrocarbon refrigerant R290. Because of the nature of hydrocarbon refrigerants, for mechanical repair, such as recharge or compressor replacement, should only be carried out by a certified refrigeration technician. The safety of this equipment is listed by Underwriter Laboratory (UL) under Standard UL471, section SB – “natural refrigerant”.

Electromagnetic Compatibility

FCC Statement (USA)
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian ISED IC Notice
This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada.
26 | Regulatory Compliance General Purpose and Chromatography Refrigerators
Page 31

Energy Efficiency

ENERGY STAR
This product family has been voluntarily evaluated, and found compliant, by an EPA approved certification body to the EPA ENERGY STAR Laboratory Grade Refrigerators and Freezers Specification 1.1.

Additional Regulations and Markings

This product is not marked with a CE marking, as it does not operate in the voltage range to be sold to the EU Member States or European Economic area (EEA). Please reach out to the manufacturer for questions regarding any additional regulatory conformity.
General Purpose and Chromatography Refrigerators Regulatory Compliance | 27
Page 32
WEEE Comphliance
Great Britain
WEEE Compliance. This prod
Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked with the following symbol. Thermo Fisher Scientific has contracted with one or more recycling/disposal companies in each EU Member State, and this product should be disposed of or recycled through them.
WEEE Konformittät. Dieses Produkt muss die EU Waste Electrical & Electronic Equipment (WEEE) Richtlinie 2012/19/EU erfüllen. Das Produkt ist durch folgendes Symbol gekennzeichnet. Thermo Fisher Scientific hat Vereinbarungen getroffen mit Verwertungs-/Entsorgungsanlagen in gliederstaaten und dieses Produkt muss durch diese Firmen widerverwetet oder entsorgt werden.
Conformità WEEE. Questo prodotto deve rispondere alla direttiva dell’ Unione Europea 2012/19/EU in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici (WEEE). È marcato col seguente simbolo. Thermo Fischer Scientific ha stipulato contratti con una o diverse società di riciclaggio/smaltimento in ognuno degli Stati Membri Europei. Questo prodotto verrà smaltito o riciclato tramite queste medes­ime.
Conformité WEEE. Ce produit doit être conforme à la directive euro-péenne (2012/19/EU) des Déchets d’Equipements Electriques et Electroniques (DEEE). Il est marqué par le symbole suivant. Thermo Fisher Scientific s’est associé avec une ou plusieurs compagnies de recyclage dans chaq état membre de l’union européenne et ce produit devraitêtre collecté ou recyclé par celles-ci.
uct is required to comply with the European Union’s Waste Electrical &
allen EU-Mit-
ue
Deutschland
Italia
France
Page 33
IF YOU NEED ASSISTANCE:
Thermo Fisher Scientific products are backed by a global technical support team ready to support your applications. We offer cold storage accessories, including remote alarms, temperature recorders, and validation services. Visit
www.thermofisher.com/cold or call:
Countries Sales
North America +1 866 984 3766
India toll free 1800 22 8374
India +91 22 6716 2200
China +800 810 5118, +400 650 5118
Japan +81 3 5826 1616
Australia +61 39757 4300
Austria +43 1 801 40 0
Belgium +32 53 73 42 41
France +33 2 2803 2180
Germany international +49 6184 90 6000
Germany national toll free 0800 1 536 376
Italy +32 02 95059 552
Netherlands +31 76 579 55 55
Nordic/Baltic/CIS countries +358 9 329 10200
Russia +7 812 703 4215
Spain/Portugal +34 93 223 09 18
Switzerland +41 44 454 12 22
UK/Ireland +44 870 609 9203
New Zealand +64 9 980 6700
Other Asian Countries +852 2885 4613
Countries not listed +49 6184 90 6000
Thermo Fisher Scientific Inc. 275 Aiken Road Asheville, NC 28804 United States
Find out more at thermofisher.com/cold
© 2018 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. 329137H01 0818
Page 34
Réfrigérateurs de chromatographie et à usage général
Série TSG
Installation et fonctionnement
329137H01 Révision B août 2018
Page 35
IMPORTANT Lisez ce mode d'emploi. Le non-respect des consignes du présent manuel peut entraîner des dégâts au niveau de l'unité, des blessures au personnel et de mauvaises performances de l'équipement.
ATTENTION Tous les réglages internes et la maintenance doivent être exécutés par un personnel de service qualifié.
Le présent manuel est publié à titre d'information uniquement. Le contenu et le produit qu'il décrit peuvent être modifiés sans préavis. Thermo Fisher Scientific ne fait aucune déclaration ni ne donne aucune garantie quant à ce manuel. En aucun cas Thermo ne saurait être tenu responsable des dommages, directs ou indirects, liés à l'utilisation du présent manuel.
© 2018 Thermo Fisher Scientific Inc. Tous droits réservés.
Pour toute référence ultérieure et lorsque vous contactez l'usine, ayez les informations suivantes à portée de main. Vous trouverez ces informations sur la plaque signalétique fixée à votre unité.
Numéro de modèle :
Numéro de série :
Les informations suivantes, si elles sont disponibles, vous seront utiles pour contacter l'usine.
Date d'achat :
Numéro de bon de commande :
Provenance des achats :
(fabricant ou agent/représentant de l'entreprise)
Page 36

Table des matières

Modèle ........................................................................ 1
Mesures de sécurité..................................................... 2
Déballage..................................................................... 4
Liste de colisage .......................................................... 4
Recommandations générales....................................... 5
Contrôle de la température....................................... 5
Utilisation prévue...................................................... 5
Premier remplissage................................................. 5
Conditions de fonctionnement ..................................... 6
Caractéristiques de l'unité ........................................ 6
Installation.................................................................... 8
Emplacement........................................................... 8
Nivellement de l'unité ............................................... 8
Installation des roulettes et retrait de la palette ......... 8
Réfrigérateurs de chromatographie .......................... 10
Câblage ................................................................... 11
Étagères................................................................... 13
Consignes d'installation............................................ 13
Fonctionnement de la porte...................................... 13
Alarme à distance .................................................... 13
Dernières vérifications .............................................. 14
Démarrage................................................................... 15
Premier démarrage .................................................. 15
Réfrigérateurs de chromatographie .......................... 15
Recommandations relative au remplissage
et au vidage des produits ......................................... 15
Page 37
Fonctionnement........................................................... 16
Panneau de commande ........................................... 16
Température de consigne ........................................ 17
Alarmes.................................................................... 17
Réglages des paramètres du contrôleur................... 18
Entretien ...................................................................... 21
Nettoyage de l'intérieur de l'armoire ......................... 21
Nettoyage de l'unité (réfrigérateurs
de chromatographie) ................................................ 21
Nettoyage du condenseur........................................ 21
Dégivrage automatique ............................................ 21
Entretien des joints d'étanchéité............................... 21
Entretien de la pile de l'alarme.................................. 22
Préparation pour le stockage ................................... 22
Nettoyage de l'unité (réfrigérateurs
de chromatographie) ................................................ 22
Remplacement du capteur (réfrigérateurs
de chromatographie) ................................................ 22
Entretien du capteur (réfrigérateurs
de chromatographie) ................................................ 22
Dépannage .................................................................. 23
Soins de Fin de vie....................................................... 24
Garantie....................................................................... 25
Conformité réglementaire............................................. 26
Sécurité des produits ............................................... 26
Compatibilité électromagnétique .............................. 26
Rendement énergétique........................................... 27
Autres réglementations et marquages ...................... 27
Page 38

Modèle

Le tableau ci-dessous présente les unités traitées dans ce manuel d'installation et de fonctionnement par numéro de modèle.
Tableau 1. Modèles applicables
Réfrigérateur
TSG12RPGA TSG45RSLA
TSG25RPGA TSG45CSLA
TSG25RPSA TSG49RPGA
TSG25RSGA TSG49CPGA
TSG25RSSA TSG49RPSA
TSG30RPGA TSG49RSGA
TSG30CPGA TSG49CSGA
TSG30RPSA TSG49RSSA
TSG30RSGA TSG72RPGA
TSG30CSGA TSG72CPGA
TSG30RSSA TSG72RSGA
TSG45RPLA TSG72CSGA
TSG45CPLA
L'annotation des numéros de modèle est donnée dans le tableau suivant :
Tableau 2. Spécifications du modèle
Série TSG (Thermo Scientific)
Taille (litres) 12, 25, 30, 45, 49, 72
Type R = Réfrigérateur
C = Chromatographie
Extérieur P = Peint
S = Inoxydable
Type de porte S = Pleine
G = Vitrée L = Coulissante vitrée
Tension A = 115 V / 60 Hz
Réfrigérateurs de chromatographie et à usage général Modèle | 1
Page 39

Mesures de sécurité

Le présent manuel utilise les symboles et conventions ci­après.
AVERTISSEMENT: lorsqu'il est utilisé seul, ce
symbole indique des consignes de fonctionne­ment importantes qui limitent le risque de bles­sure ou de mauvaise performance de l'unité.
AVERTISSEMENT: ce symbole indique une
situation potentiellement dangereuse qui, si elle n'est pas évitée, pourrait entraîner des blessures graves ou mortelles.
AVERTISSEMENT: ce symbole indique des
situations présentant des tensions dangereuses et un risque d'électrocution.
AVERTISSEMENT: ce symbole indique une
situation potentiellement dangereuse qui, si elle n'est pas évitée, pourrait entraîner un incendie.
ATTENTION: dans le contexte d'un ATTENTION,
ce symbole indique une situation potentiellement dangereuse qui, si elle n'est pas évitée, pourrait entraîner des blessures légères à modérées ou endommager l'équipement. Ce symbole indique une situation pouvant provoquer des dommages matériels.
ATTENTION: ce symbole indique des surfaces
pouvant chauffer au cours de l'utilisation et cau­ser des brûlures en cas de contact avec des par­ties du corps non protégées.
AVERTISSEMENT: il convient de lire attentive-
ment le manuel et les étiquettes d'avertissement avant l'installation, l'utilisation ou la maintenance de ce produit. Le non-respect de ces consignes peut entraîner un mauvais fonctionnement de l'unité et entraîner une blessure ou un dommage.
ATTENTION: ce symbole indique d'éventuels
points de pincement pouvant causer des bles­sures.
AVERTISSEMENT: le symbole en forme de
flocon de neige indique de faibles températures et un risque de gelures. Ne touchez pas le métal nu ni les échantillons sans protection.
Les mesures de sécurité importantes suivantes s'appliquent à ce produit.
ATTENTION: utilisez ce produit uniquement
comme décrit dans la documentation et le manuel correspondants. Vérifiez préalablement que ce produit est adapté à son utilisation pré­vue. Si l'équipement n'est pas utilisé conformé­ment aux spécifications du fabricant, la protection risque d'être compromise.
ATTENTION: ne modifiez pas les composants
du système, notamment le régulateur. N'utilisez que le matériel ou les pièces de remplacement du fabricant d'origine. Avant l'utilisation, confir­mez que le produit n'a été modifié d'aucune façon
AVERTISSEMENT: votre unité doit être correc-
tement mise à la terre, conformément aux codes nationaux et locaux de l'électricité. Ne branchez pas l'unité sur des sources électriques surchar­gées.
AVERTISSEMENT: débranchez l'unité de toutes
les alimentations électriques avant de procéder aux opérations de nettoyage, de dépannage ou de maintenance sur le produit ou sur ses commandes.
AVERTISSEMENT: cette unité n'est pas desti-
née à stocker des matériaux inflammables.
AVERTISSEMENT: les unités contiennent des
réfrigérants à base d'hydrocarbures (R290). Seul un personnel d'entretien qualifié est habilité à entretenir cette unité.
AVERTISSEMENT: toute réparation non autori-
sée réalisée sur votre unité annulera la garantie. Contactez le service technique au 1-866-984­3766 pour plus d'informations.
DANGER: risque d'incendie ou d'explosion. Les
fuites de réfrigérants inflammables sont réparées uniquement par un personnel d'entretien qualifié. Ne perforez pas les conduites de réfrigérants.
AVERTISSEMENT: ne placez aucun équipe-
ment utilisant une flamme nue à l'intérieur du réfrigérateur. Vous risquez d'endommager l'unité mais aussi de compromettre son fonctionnement et votre sécurité.
ATTENTION: n'utilisez pas d'équipements ali-
mentés par piles ou en externe dans le réfrigéra­teur.
2 | Mesures de sécurité Réfrigérateurs de chromatographie et à usage général
Page 40
D'autres mesures de sécurité s'appliquent à ce produit. Modèles de réfrigérateurs de chromatographie :
ATTENTION: l'équipement doit être alimenté
uniquement à l'aide de la prise interne. En cas de fuite, le circuit de sécurité coupera le courant au niveau de la prise de l'unité mais n'aura aucun contrôle sur l'alimentation de l'équipement via des piles ou une alimentation externe. N'utilisez pas des instruments ou un équipement qui intègrent des sources d'inflammation poten­tielles, par ex. la commutation à contacts ouverts, les moteurs à balais à courant alternatif et à courant alternatif, etc.
ATTENTION: le circuit de sécurité du réfrigéra-
teur de chromatographie présente des fentes/ trous sur la partie inférieure de la prise afin de permettre à l'air de ventiler le capteur de sécurité. Ne bouchez pas les trous de ventilation du circuit de sécurité car vous risquez de l'endommager.
AVERTISSEMENT: ne stockez pas ou n'utilisez
pas des réactifs, des récipients et des flacons non refermés à l'intérieur du réfrigérateur de chromatographie. Vous risquez de diminuer la fonctionnalité du circuit de sécurité.
Réfrigérateurs de chromatographie et à usage général Mesures de sécurité | 3
Page 41

Déballage

À la livraison, vérifiez qu'il n'y a pas de dommages matériels extérieurs en présence du représentant du transporteur. En cas de dommage extérieur, déballez avec précaution et véri­fiez que l'unité ainsi que tous les accessoires ne sont pas endommagés.
Si c'est le cas, déballez et inspectez l'équipement dans les cinq jours à compter de la date de livraison. Si l'extérieur est endommagé, conservez l'emballage et signalez-le immédia­tement au transporteur.
Ne renvoyez pas la marchandise au fabricant sans
utorisation écrite.
a
Lorsque vous envoyez une réclamation pour dommages à l'exp
édition, demandez à ce que le transporteur inspecte le
conteneur de transport et l'équipement.

Liste de colisage

L'unité a été emballée avec les articles suivants :
Manuel d'installation et de fonctionnement dans un en
veloppe blanche.
Clé de porte et interrupteur à clé attachés au montant su la
partie supérieure avant.
Petit sachet contenant les clips des étagères.
•Étagères.
Demi-étagères (avec réfrigérateurs de chromatographie).
Cordon d'alimentation (avec réfrigérateurs
hromatographie et 25, 30 cf réfrigérateurs)
c
Roulettes (Applicable pour 12cf, 25cf et 30cf modèle
lement).
seu
Clé (Applicable pour 12cf, 25cf et 30cf modèle
lement).
seu
à
e
s
s
r
4 | Déballage Réfrigérateurs de chromatographie et à usage général
Page 42

Recommandations générales

Cette section contient des recommandations générales pour votre unité.
Contrôle de la température
REMARQUE IMPORTANTE : nous recomman­dons l'utilisation d'un système de contrôle de la température redondant et indépendant afin de garantir un contrôle constant des performances proportionnellement à la valeur du produit stocké.
Utilisation prévue
Les réfrigérateurs décrits dans ce manuel sont des unités de laboratoire à usage général destinées à stocker des échantil­lons non critiques à des températures de fonctionnement comprises entre 2 et 10 °C.
Ces unités ne sont pas enregistrées comme appareils médi­caux auprès d'un organisme de réglementation des disposi­tifs médicaux (ex. : FDA). Cela signifie qu'elles n'ont pas été évaluées pour le stockage d'échantillons à des fins de dia­gnostic ou pour la réintroduction d'échantillons dans le corps.
Premier remplissage
Laissez l'unité fonctionner à la température souhaitée pen­dant au moins 12 heures avant de la remplir.
Remplissez l'unité une étagère à la fois, en commençant par l'étagère du dessous. Après avoir rempli une étagère, atten­dez que l'unité revienne au point de consigne avant de placer des produits sur une autre étagère. Répétez l'opération jusqu'à ce que l'unité soit complètement remplie. Consultez la section sage des étagères.
Étagères pour connaître les capacités de remplis-
ATTENTION: le non-respect de ces procédures
ou la surcharge de l'unité risque de solliciter inuti­lement les compresseurs ou de compromettre la sécurité du produit de l’utilisateur.
Cette unité ne doit pas être utilisée dans des lieux classés comme dangereux ni pour le stockage de produits inflam­mables ou corrosifs.
Ces réfrigérateurs ne sont pas adaptés pour un usage en extérieur.
ATTENTION:
sives dans des contenants ouverts peut provo­quer de la corrosion à l'intérieur de l'unité.
le stockage de substances corro-
Réfrigérateurs de chromatographie et à usage général Recommandations générales | 5
Page 43

Conditions de fonctionnement

Les unités décrites dans ce manuel sont classés pour une uti­lisation en tant qu'équipement fixe dans un environnement au degré de pollution 2 et à la catégorie de surtension II.
Ces unités sont conçues pour fonctionner dans les conditions environnementales suivantes :
Utilisation en intérieur
Altitude jusqu'à 2000 m
Humidité relative maximale de 60 % pour des températures comprises entre 15 °C et 32 °C
Variations des tensions de l'alimentation principale non supérieures à ±10 % par rapport à la tension nominale
Ne branchez pas l'unité sur une prise électrique protégée par un disjoncteur différentiel de fuite à la terre (DDFT) car elle peut se déclencher de manière intempestive.
Ne faites pas fonctionner cette unité à l'aide d'une rallonge.
Caractéristiques de l'unité
La plaque signalétique se situe sur la partie supérieure gauche vers l'avant de l'unité.
Les caractéristiques du réfrigérateur, comme la tension, l'ampérage du disjoncteur et le type de prise électrique sont identiques sur toutes les unités.
Tension = 115 V/60 Hz Ampérage du disjoncteur = 15 A Prise chromatographie = NEMA 5-15P Cette prise doit être branchée sur/fournie avec son propre cir-
cuit de dérivation.
ATTENTION: les unités de chromatographie
sont fournies avec deux cordons d'alimentation distincts. Prenez soin de débrancher les deux cordons durant le déplacement, l'essai ou la réparation du produit.
D'autres caractéristiques figurent dans le tableau ci-dessous.
Tableau 3. Caractéristiques de l'unité
Unité Taille
(litres)
TSG12RPGA 340 Peint Vitre 4 1925,9 x 628,6 x 635,0 mm
TSG25RPGA 708 Peint Vitre 4 2057,1 x 704,8 x 812,8 mm
TSG25RPSA 708 Peint Pleine 4 2057,1 x 704,8 x 812,8 mm
TSG25RSGA 708
TSG25RSSA 708
TSG30RPGA 850 Peint Vitre 4 2057,1 x 781,0 x 812,8 mm
TSG30CPGA 850 Peint Vitre
TSG30RPSA 850 Peint Pleine 4 2057,1 x 781,0 x 812,8 mm
TSG30RSGA 850
TSG30CSGA 850
Extérieur Type de
porte
Acier inoxydable
Acier inoxydable
Acier inoxydable
Acier inoxydable
Vitre 4 2057,1 x 704,8 x 812,8 mm
Pleine 4 2057,1 x 704,8 x 812,8 mm
Vitre 4 2057,1 x 781,0 x 812,8 mm
Vitre
Nb de étagères
4 + 3 demi­étagères
4 + 3 demi­étagères
Dimensions extérieures (H x l x P)
2057,1 x 781,0 x 812,8 mm
2057,1 x 781,0 x 812,8 mm
6 | Conditions de fonctionnement Réfrigérateurs de chromatographie et à usage général
Page 44
Tableau 3. Caractéristiques de l'unité
Unité Taille
(litres)
TSG30RSSA 850
TSG45RPLA 1 274 Peint
TSG45CPLA 1 274 Peint
TSG45RSLA 1 274
TSG45CSLA 1 274
TSG49RPGA 1 387 Peint Vitre 8 2057,1 x 1338,6 x 812,8 mm
TSG49CPGA 1 387 Peint Vitre
Extérieur Type de
porte
Acier inoxydable
Acier inoxydable
Acier inoxydable
Pleine 4 2057,1 x 781,0 x 812,8 mm
Coulis­sante vitrée
Coulis­sante vitrée
Coulis­sante vitrée
Coulis­sante vitrée
Nb de étagères
8 2057,1 x 1338,6 x 812,8 mm
8 + 2 demi­étagères
8 2057,1 x 1338,6 x 812,8 mm
8 + 2 demi­étagères
8 + 2 demi­étagères
Dimensions extérieures (H x l x P)
2057,1 x 1338,6 x 812,8 mm
2057,1 x 1338,6 x 812,8 mm
2057,1 x 1338,6 x 812,8 mm
TSG49RPSA 1 387 Peint Pleine 8 2057,1 x 1338,6 x 812,8 mm
TSG49RSGA 1 387
TSG49CSGA 1 387
TSG49RSSA 1 387
TSG72RPGA 2 039 Peint Vitre 12 2057,1 x 1924,0 x 812,8 mm
TSG72CPGA 2 039 Peint Vitre
TSG72RSGA 2 039
TSG72CSGA 2 039
Acier inoxydable
Acier inoxydable
Acier inoxydable
Acier inoxydable
Acier inoxydable
Vitre 8 2057,1 x 1338,6 x 812,8 mm
Vitre
Pleine 8 2057,1 x 1338,6 x 812,8 mm
Vitre 12 2057,1 x 1924,0 x 812,8 mm
Vitre
8 + 2 demi­étagères
12 + 2 demi­étagères
12 + 2 demi­étagères
2057,1 x 1338,6 x 812,8 mm
2057,1 x 1924,0 x 812,8 mm
2057,1 x 1924,0 x 812,8 mm
Réfrigérateurs de chromatographie et à usage général Conditions de fonctionnement | 7
Page 45

Installation

AVERTISSEMENT:
cité électrique imprimée sur la plaque signalé­tique située en haut à gauche de l'unité.
ne dépassez pas la capa-
Emplacement
Installez l'unité dans un endroit de niveau et exempt de vibra­tions en respectant un espacement minimum de 8 cm sur les côtés et de 10 cm sur le dessus. Ne placez pas l'équipement à la lumière directe du soleil, à proximité de diffuseurs de cha­leur, de radiateurs ou d'autres sources de chaleur.
Remarque : ne déplacez pas l'unité lorsqu'elle est complètement remplie.
Nivellement de l'unité
Le réfrigérateur doit être mis de niveau afin de permettre un écoulement approprié de la condensation mais aussi un ali­gnement et un fonctionnement corrects de la porte. Installez le réfrigérateur dans son emplacement définitif et de manière à ce qu'il soit stable au niveau du sol. Nivelez l'armoire d'avant en arrière et sur les côtés à l'aide des vis de réglage. Les vis de réglage à l'avant sont accessibles en retirant la gille, comme décrit ci-dessous :
Remarque : Roulettes disponibles pour 12, 25 et 30 cu. unités ft. Pieds de nivellement seulement sur 45, 49 et 72 cu. unités de pi
Sans chariot élévateur
Outils nécessaires : tournevis cruciforme, clés de 11 et de 9 mm, au moins deux personnes.
Toutes les unités sont expédiées avec des pieds installés d'usine dont les roulettes sont fournies à l'intérieur de l'unité. Les instructions suivantes vous montrent comment retirer l'armoire de son support d'expédition (palette) et installer les roulettes sans l'aide d'un chariot élévateur.
1. Retirez les vis de fixation de la grille inférieure.
2. Saisissez la grille avec vos deux mains.
3. Soulevez la grille d'environ 1 cm.
4. Retirez la grille du réfrigérateur.
Installation des roulettes et retrait de la palette
ATTENTION: évitez d'endommager les
conduites de réfrigérant, vous risquez de provo­quer une fuite pendant la manutention, le dépla­cement et le fonctionnement de l'unité.
Remarque : déballez l'unité à proximité de son emplacement définitif.
1. Retirez l'emballage et les plaques de l'unité. Retirez l'autre emballage afin d'accéder à l'intérieur de l'armoire. Veillez à conserver un coin en carton pour l'étape suivante.
2. À l'aide du tournevis, retirez les vis qui maintiennent la grille avant. Soulevez la grille vers le haut et retirez-la de l'unité. Mettez-la de côté.
8 | Installation Réfrigérateurs de chromatographie et à usage général
Page 46
3. Retirez les boulons (4) qui maintiennent l'unité à la palette à l'aide de la clé de 11 mm.
Remarque : à partir de là, vous aurez besoin de l'aide d'une autre personne. Faites appel à d'autres personnes si nécessaire.
4. Avec une personne de chaque côté, faites glisser doucement l'unité jusqu'au bord de la palette. Faites glisser l'unité de manière à la faire dépasser de 8 cm environ afin de pouvoir retirer le pied installé d'usine et d'installer les roulettes.
l'arrière de l'unité. Serrez à l'aide de la clé fournie pour les roulettes.
7. Faites tourner doucement l'unité pour pouvoir installer la
dernière roulette.
Personne n° 2 : continuez de soutenir l'unité. Personne n° 1 : installez l'autre roulette à l'arrière de l'unité. Serrez
à l'aide de la clé fournie pour les roulettes.
ATTENTION:
nécessaires pour déplacer l'unité. Ne déplacez pas ou n'ajustez pas l'unité si l'autre personne est en train de travailler sur l'unité (réglage des roulettes, par exemple).
5. Personne n° 1 : restez debout à côté de la palette et apportez votre aide. Personne n° 2: retirez les 4 pieds installés d'usine (à l'aide de la clé de 9 mm pour desserrer si nécessaire). Installez les 2 roulettes au niveau du bord qui dépasse. Serrez à l'aide de la clé fournie pour les roulettes.
Remarque : certaines roulettes se bloquent, d'autres pas. Nous vous recommandons d'installer les roulettes bloquantes à l'avant de l'unité.
6. Tout en soutenant l'unité, faites-la glisser doucement jusqu'à ce que les roulettes touchent le sol. Faites glisser doucement le bord arrière de manière à ce qu'il dépasse de la palette d'environ 8 cm afin de pouvoir installer l'une des roulettes arrière. Personne n° 2: continuez de soutenir l'unité. Personne n° 1: installez une roulette à
Réfrigérateurs de chromatographie et à usage général Installation | 9
deux personnes sont encore
8. Prenez un angle en carton, pliez-le en deux et placez-le sous l'unité et contre la palette. Replacez l'unité parallèlement à la palette en utilisant le rebord de l'unité pour soutenir la palette. Une fois en place, faites rouler doucement l'unité hors de la palette.
Page 47
Avec chariot élévateur
Outils nécessaires: tournevis cruciforme, clés de 11 et de
9 mm, au moins deux personnes. Les instructions suivantes vous montrent comment retirer
l'armoire de son support d'expédition (palette) et installer les roulettes ou les pieds inférieurs à l'aide d'un chariot élévateur.
1. Retirez les vis, les boulons et les roulettes en suivant les
instructions de la section intitulée Sans chariot
élévateur.
Remarque : soyez toujours vigilant(e) lorsque vous soulevez
l'unité avec un chariot élévateur afin d'éviter d'endommager l'unité ou de la faire tomber.
l'interrupteur correspondant situé à droite du panneau supé­rieur avant de rétablir le courant. Pour cela, appuyez sur l'interrupteur situé en haut à droite du panneau supérieur à côté des contacts d'alarme à distance. Le courant au niveau de la prise arrivera au bout d'environ 4 minutes et le voyant rouge s'allumera.
Lorsque le courant arrive à la prise, le voyant rouge s'éteint et le vert s'allume.
Si le circuit passe du ROUGE au VERT constamment ou ne passe jamais au VERT, contacter le service clients.
Ne stockez jamais des matériaux inflammables dans le réfri­gérateur.
2. Placez doucement les fourches pour soulever l'unité par l'arrière. Vérifiez que l'unité est entièrement placée sur le chariot élévateur avant de lever les fourches.
3. Soulevez l'unité d'environ 15 cm afin d'avoir accès aux pieds et aux roulettes. Personne n° 1 : tenez-vous à l'avant de l'unité et soutenez également l'unité. Personne n° 2 : si vous souhaitez utiliser les pieds, abaissez les 4 pieds installés d'usine (à l'aide de la clé de 9 mm pour desserrer si nécessaire). Si vous souhaitez utiliser les roulettes, retirez les pieds puis installez les 4 roulettes et serrez à l'aide de la clé fournie.
Voyants
La prise du disjoncteur différentiel de fuite à la terre se situe au centre du panneau arrière à l'intérieur de l'unité.
La prise présente deux voyants :
ROUGE (en haut) - Si le voyant rouge est ALLUMÉ, cela signifie qu'il n'y a pas de courant au niveau de la prise c.a. à l'intérieur de l'unité.
VERT (en bas) - Si le voyant vert est ALLUMÉ, cela signifie qu'il y a du courant au niveau de la prise c.a. à l'intérieur de l'unité.
Remarque : certaines roulettes se bloquent, d'autres pas. Nous vous conseillons d'installer les roulettes bloquantes à l'avant de l'unité.
4. Retirez la palette du dessous de l'unité et abaissez doucement l'unité à son emplacement souhaité.
Réfrigérateurs de chromatographie
Le réfrigérateur de chromatographie est équipé d'un circuit de sécurité. En cas de déclenchement du circuit de sécurité (le capteur de sécurité détecte un gaz inflammable), l'alimen­tation de la prise interne est coupée et l'utilisateur devra réar­mer manuellement le circuit de sécurité à l'aide de
10 | Installation Réfrigérateurs de chromatographie et à usage général
Page 48
Interrupteurs
Les réfrigérateurs de chromatographie possèdent un interrup­teur de réarmement sur le côté droit du panneau supérieur, au-dessus des contacts d'alarme à distance.
Réarmement manuel de la chromatographie : il est utilisé pour réarmer manuellement le circuit de sécurité dans la prise c.a. une fois que le voyant passe du ROUGE au VERT suite à un événement de déclenchement de sécurité qui coupe le courant au niveau de la prise située à l'intérieur du réfrigérateur. Il est situe à droite en haut à droite à côté des contacts de l'alarme à distance.
Câblage
Le schéma de câblage des unités est illustré à la Figure 1.
ATTENTION: branchez l'équipement sur la
bonne source d'alimentation. Une tension inap­propriée risque d'endommager sérieusement l'équipement.
ATTENTION: pour votre sécurité et un fonc-
tionnement sans défaillance, cette unité doit être correctement mise à la terre. La non mise à la terre de l'équipement peut causer des dom­mages corporels ou matériels. Respectez tou­jours le code national d'électricité et les codes locaux. Ne branchez pas l'unité sur des lignes électriques surchargées.
ATTENTION: branchez toujours l'unité sur un
circuit dédié (distinct). Chaque unité est équipée d'un câble d'alimentation et d'une prise destinés à le brancher sur une prise électrique délivrant une tension adaptée. La tension d'alimentation doit être comprise entre ±10 % de la tension nominale de l'unité. Si le câble est endommagé, remplacez-le par un câble d'alimentation appro­prié. Caractéristiques du câble d'alimentation : 3-G 12 AWG, NEMA 5-15 P, 15A / 125V.
ATTENTION: ne coupez jamais la broche de
terre de la prise du câble d’alimentation. Si la broche est retirée, la garantie est caduque.
ATTENTION: débranchez le câble d'alimenta-
tion en cas d'urgence.
Réfrigérateurs de chromatographie et à usage général Installation | 11
Page 49
6&


:+,7(
%/$&.
%52:1
1'(9$3)$121
/$5*(581,7621/<
(9$3)$1
:+,7(
 
6 6
',
6
6
'$1)266&21752//(5'(7$,/
&2035(6625
5(027($/$50
/,1(
1(875$/
/,*+7
$,56(1625
(9$36(1625
5&581&$3$&,725
6&67$57&$3$&,725
2/29(5/2$'
'$1)266&21752//(57(50,1$/
&211(&7,2132,17
&5&21752/5(/$<
/(*(1'
6((&21752//(5'(7$,/
5(027($/$50&217$&76
12&201&

5(/$<
:+,7(
&2035(6625'(7$,/93+
&855(175(/$<
6
0
&21'(16(5)$1
&
6
5
&203
2/
/$03
/('/$03
32:(5
6833/<
6((&21752//(5'(7$,/
6((&21752//(5'(7$,/
6((&21752//(5'(7$,/
-
-
-
52&.(5
6:,7&+
-

$&287/(7
5(/$<

'&,1
-
+&6(1625
%2$5'


*5((1
/('
5('
/('
32:(56833/<
6,*1$/
&21',7,21,1*
%2$5'
.(<6:


1&
&20
&2,/
5(/$<
)250&
.(<6:
9
%$77(5<
%8==(5
/('



%/$&.
%/8(
<(//2:
%/$&.
%/$&.
%/$&.
5('
%52:1
%/$&.
%52:1
:+,7(
%/8(
%/8(
%52:1
%/8(
%52:1
%/$&.
%/$&.
%/$&.
%/$&.
%52:1
%/8(
%/$&.
*5((1
:+,7(
*5$<
%/$&.
5('
5('
&+520$72*5$3+<5()5,*(5$725621/<
%/$&.
:+,7(
%52:1
%/8(:+,7(
%52:1
%/$&.
*5((1
<(//2:
:+,7(
5('
:+,7(
*5((1
*5((1
*5((1
5('
%/$&.
*5((1
<(//2:
%/8(
:+,7(

*5((1
<(//2:
(0,
),/7(5
(0,),/7(521/<
)25&)&)
5()5,*(5$7256
Figure 1. Schéma de câblage
12 | Installation Réfrigérateurs de chromatographie et à usage général
Page 50
Étagères
Toutes les unités sont livrées avec des étagères métalliques. Chaque unité comporte un nombre d'étagères différent. Reportez-vous au Tab le au 3 pour obtenir plus d'informa­tions.
a capacité maximale des étagères est de 45 kg pour les éta-
L gères pleines et de 22,5 kg pour les demi-étagères.
Pour des raisons de sécurité, les étagères sont emballées et fixées à l'intérieur de l'armoire lors de l'expédition. Insérez les crochets de support d'étagère (inclus avec le manuel à l'inté­rieur de l'unité) dans les supports d'étagère intégrés (situés sur les parois internes à l'intérieur de l'armoire) aux endroits souhaités.
1. Déterminez un endroit approprié pour installer les clips d'
étagère. Le numéro de référence sur le montant peut
servir de guide afin de placer correctement tous les clips.
2. Insérez la partie supérieure du clip dans le trou souhaité du montant avec la patte de retenue tournée vers le haut
3.
Tournez le clip vers le bas et insérez la patte inférieure dans le trou approprié. Le clip peut coincer légèrement durant l'installation.
4.
Installez les étagères dans les clips avec la barre de retenue des produits tournée vers le haut. Attention à ne pas écraser les clips durant l'installation des étagères.
5. Avant de remplir une étagère, vérifiez qu'elle repose bien sur les 4 clips et que les clips sont bien installés.
ATTENTION: une mauvaise installation des clips
peut endommager l'unité.
ATTENTION: ne surchargez pas les étagères.
unité est conçue pour utiliser toutes les éta-
L' gères fournies et espacées de manière égale.
.
Figure 2. Agencement des étagères
Figure 3. Clip d'étagère
Fonctionnement de la porte
Les unités à portes battantes sont conçues pour rester ouvertes si les portes sont ouvertes à au moins 90°. La ten­sion du ressort de porte ne peut pas être réglé.
Les portes coulissantes peuvent être ouvertes complètement vers la gauche ou vers la droite. Si la porte à fermeture auto­matique ne fonctionne pas correctement, vérifiez que l'unité est bien de niveau.
Joint de porte
ATTENTION: l'intégrité du join
essentielle au bon fonctionnement de l'unité. Un joint non ajusté laisse passer l'air humide dans l'armoire, entraînant une accumulation de givre plus rapide au niveau des parois, des temps de fonctionnement plus longs, un maintien difficile de la température et une hausse des coûts de fonctionnement.
t de porte est
Consignes d'installation
AVERTISSEMENT: ne déplacez pas l'unité
lorsqu'ell
Réfrigérateurs de chromatographie et à usage général Installation | 13
e est remplie.
Alarme à distance
Toutes les unités sont dotées de contacts d'alarme à dis­tance installés d'usine qui peuvent être utilisés pour les sys­tèmes d'alarme à distance. La distance maximale entre une unité et une alarme à distance dépend du calibre de câble uti­lisé. Reportez-vous au Ta b le a u 4 ci-dessous :
Page 51
Les contacts de l'alarme à distance se situent à droite du
nneau supérieur. Les trois terminaux sont : COMMON,
pa OPEN ON FAIL (normalement fermé) et CLOSE ON FAIL (normalement ouvert).
Tableau 4. Calibre de câble et distance jusqu'à l'alarme à distance
Calibre du câble
20 161,5 80,75
18 256 128
16 405 202,5
14 646 323
12 1027 513,5
Pour installer l'alarme à distance, procédez aux branche­ments suivants :
1. Branchez le terminal COMMO l'alarme sur le câble COMMON de l'alarme.
2. Pour déclencher une alarme lorsque les contacts de l'interrupteur sont ouverts, branchez le terminal OPEN ON FAIL de l'armoire sur le câble OPEN ON FAIL de l'alarme.
3. Pour déclencher une alarme lorsque les contacts de l'interrupteur sont fermés, branchez le terminal CL O l'alarme. Les câbles COMMON et CLOSE ON FAIL doivent être reliés ensemble dans cette application.
Longueur totale du câble (m)
N FAIL de l'armoire sur le câble CLOSE ON FAIL de
Distance jusqu'à l'alarme 1/2 longueur de câble (m)
N de l'interrupteur de
OSE
4. Branchez le câble d'alimentation du système d'alarme sur une prise électrique
Les contacts se déclencheront en cas d'alarme de
5. température élevée ou d'alarme de température basse.
.
Dernières vérifications
Avant de démarrer, suivez les étapes ci-dessous :
1. Vérifiez que l'unité est débarrassée de tout carton ou m
atériau d'expédition à l'intérieur et à l'extérieur.
2. Vérifiez la position des étagères. Si vous souhaitez ajuster les positions.
3. Vérifiez que l'unité est branchée sur un circuit distinct.
14 | Installation Réfrigérateurs de chromatographie et à usage général
Page 52

Démarrage

Premier démarrage
Pour démarrer l'unité, suivez les étapes ci-dessous :
1. Branchez le câble d'alimentation principale c.a. Les ventilateurs de l'évaporateur démarrent dès que le câble d'alimentation est branché.
2. Insérez la clé argentée dans l'interrupteur et placez-le sur la position MARCHE.
3. Patientez jusqu'à ce que l'unité atteigne sa température de fonctionnement avant de commencer à la remplir de produits. Pour stabiliser le profil de température, il est recommandé d'attendre 24 heures.
4. Si vous souhaitez activer l'alarme coupure de courant, tournez l'interrupteur à clé à trois positions un tour de plus dans le sens des aiguilles d'une montre jusqu'à la position All Alarm On (toutes les alarmes activées).
5. Si vous avez une alarme à distance, branchez-la maintenant (voir la section Alarme à distance).
6. Vous pouvez, si vous le souhaitez, fermer la porte de l'armoire à clé avec la clé argentée. Placez le double des clés dans un lieu sûr.
Toutes les commandes devraient désormais être fonction­nelles, l'alarme doit être activée (si désactivée), ainsi que tous les voyants visuels.
5. Le voyant rouge situé sur le circuit de sécurité de chromatographie s'allume.
6. Au bout de 4 minutes, le voyant rouge du circuit de sécurité de chromatographie s'éteint et le voyant vert de ce même circuit s'allume.
Remarque : lors du premier allumage, la prise du disjoncteur différentiel de fuite à la terre ne sera alimentée qu'au bout de 4 minutes environ.
L'équipement opérationnel à l'intérieur du réfrigérateur peut faire varier le profil de température de l'unité. Surveillez le réfri­gérateur afin de détecter une telle variation.
Recommandations relative au remplissage et au vidage des produits
Lorsque vous remplissez votre unité, veillez à respecter les recommandations suivantes :
Répartissez la charge aussi uniformément que possible. L'uniformité de la température dépend de la circulation de l'air. Celle-ci peut être obstruée si l'unité est surchargée de produits, notamment en haut de l'armoire.
Réfrigérateurs de chromatographie
1. Branchez le câble d'alimentation principale c.a.
2. Branchez le câble d'alimentation du disjoncteur différentiel de fuite à la terre c.a.
3. Vérifiez que l'interrupteur de réarmement est sur la position MARCHE.
4. Insérez la clé argentée dans l'interrupteur et placez-le sur la position MARCHE. L'écran affichera la température actuelle de l'armoire.
Remarque : le réfrigérateur de chromatographie est expédié avec un interrupteur de réarmement manuel situé en haut à droite du panneau supérieur au-dessus des contacts de l'alarme à distance (voir la section Interrupteurs) sur la position MARCHE. L'interrupteur de réarmement manuel doit toujours être sur la position MARCHE.
Pour des applications critiques, veillez à ce que les systèmes d'alarme fonctionnent et sont activés avant de remplir votre unité.
Vérifiez qu'il y a bien un espacement entre le haut des produit et le bas des composants de stockage internes. L'absence d'espacement peut altérer les performances de l'unité ou empêcher le fonctionnement du composant de stockage.
Réfrigérateurs de chromatographie et à usage général Démarrage | 15
Page 53

Fonctionnement

Panneau de commande
Figure 4. Panneau de commande
1. Écran : lors du fonctionnement normal, l'écran affiche la
température de l'armoire en degrés Celsius telle que mesurée par le capteur principal. Lorsque l'alarme et le compresseur sont actifs, les voyants correspondants s'affichent. Consultez le tableau ci-dessous pour connaître les symboles des voyants. Un code d'affichage apparaît également lors du fonctionnement en fonction du type d'alarme.
Voy ant dégivrage
Allumé fixe : dégivrage actif
Éteint : pas de dégivrage
Voy a nt alarme
Allumé fixe : alarme présente
Clignotant : alarme désactivée
Éteint : pas d'alarme
Voyant compresseur
Allumé fixe : compresseur actif
Clignotant : temporisation, protection ou activation bloquée
Éteint : pas d'alarme
2. Dégivrage : ce bouton permet de dégivrer manuelle­ment l'unité mais aussi de retourner aux réglages des paramètres.
3. SC : ce bouton permet d'allumer et d'éteindre le voyant de l'armoire d'un simple geste. Il permet également de sélectionner une option dans les paramètres.
4. Haut : permet de faire défiler les éléments du menu et d'augmenter les valeurs.
5. Bas : permet de faire défiler les éléments du menu et de diminuer les valeurs.
6. Voyant coupure de courant : ce voyant indique une coupure de courant au niveau de l'unité. Le clignotement indique une coupure de courant.
7. Interrupteur à clé : permet d'allumer et d'éteindre le contrôleur et l'alarme coupure de courant.
Remarque : ce n'est pas un dispositif de débranchement principal. Par conséquent, même si l'interrupteur à clé est éteint, le ventilateur sera allumé car il est branché. Débran­chez le câble d'alimentation pour éteindre complètement l'unité.
8. Arrêt : met le contrôleur hors tension.
9. Allumage : met sous tension le contrôleur et est utilisé pour désactiver l'alarme coupure de courant.
10. Toutes les alarmes allumées : allume l'alarme coupure de courant sonore.
16 | Fonctionnement Réfrigérateurs de chromatographie et à usage général
Page 54
Température de consigne
Alarmes
Tous les réfrigérateurs de laboratoire ont une température de consigne par défaut d'usine de 5 °C. Il est déconseillé de modi­fier le point de consigne. Si vous devez tout de même modifier le point de consigne, suivez les instructions ci-dessous.
L'écran affiche la température actuelle.
Appuyez sur le bouton haut / bas pour augmenter / diminuer la température de consigne.
Au bout de 30 secondes, l'écran affiche de nouveau automa­tiquement la température actuelle.
Le système d'alarme est conçu pour fournir des signaux d'avertissement visuels et sonores en cas de coupure de courant et d'augmentation de la température. L'alarme est équipée d'une pile de secours.
Le système d'alarme coupure de courant est activé unique­ment si l'interrupteur à clé est sur la position alarme coupure de courant MARCHE.
Les alarmes de température basse, température haute et porte entrouverte sont réglées sur la position MARCHE par défaut dès que le contrôleur est allumé. Elles ne peuvent pas être désactivées.
Les valeurs des alarmes basse et haute par défaut sont 2 °C et 10 °C. Ces valeurs peuvent être réglées en suivant les ins­tructions de la section
Remarque : le modèle avec portes coulissantes n'est pas doté de l'alarme porte ouverte.
Le signal d'avertissement sonore retentit en cas de coupure de courant, de déclenchement d'alarme de température ou si la porte reste entrouverte pendant plus d'une minute.
Les codes des alarmes pour température haute, température basse, défaut capteur, porte entrouverte figurent dans le
Tableau 5.
Température de consigne.
Tableau 5. Codes des alarmes
Code de alarme
“Hi” Température de
“Lo” Température de
“dor” Porte ouverte plus
“E01” Erreur “S1” Toujours “E01” clignotant. Si défini : le re-
“E02” Erreur “S2” Toujours “E02” clignotant. Si défini : le re-
Réfrigérateurs de chromatographie et à usage général Fonctionnement | 17
Déclenchement Acquittement
automatique
Défini par l'air supérieure à “ALA->Hat” pour “ALA->Htd”
l'air inférieure à “LAt” pour “Ltd”
longtemps que “ALA->dod”
l'utilisateur
Défini par
l'utilisateur
Toujours “dor” clignotant. Si défini : le relais
Résultats Commentaires
“Hi” clignotant avec la température la plus haute ; Si défini : le relais d'alarme se ferme, l'avertisseur retentit.
“Lo” clignotant avec la température la plus basse ; Si défini : le relais d'alarme se ferme, l'avertisseur retentit.
d'alarme se ferme, l'avertisseur re­tentit.
lais d'alarme se ferme, l'avertis­seur retentit.
lais d'alarme se ferme, l'avertis­seur retentit.
Alarme température haute
Alarme température basse
Alarme porte ouverte
“S1” défaut capteur = (court ou ouvert)
“S2” défaut capteur = (court ou ouvert)
Page 55
Désactivation de l'alarme
Protection par mot de passe
Pour couper le son de l'alarme coupure de courant, placez l'interrupteur à clé sur la position MARCHE. L'alarme coupure de courant ne sera plus audible mais le voyant rouge sera allumé sur le panneau de commande.
Il est possible de couper le son des alarmes température haute, température basse, défaut capteur et porte entrou­verte en appuyant sur une touche du contrôleur.
Lorsque l'alarme est activée, le code de l'alarme clignote alternativement avec la température et le symbole de l'alarme.
Une fois le son de l'alarme coupé, le code s'arrête de cligno­ter mais la température et le symbole de l'alarme restent affi­chés.
L'unité est protégée par un mot de passe à l'exception du point de consigne qui peut être modifié sans mot de passe. Le mot de passe par défaut est 0.
Pour modifier les paramètres, vous devez saisir un mot de passe.
1. Appuyez sur le bouton haut / bas pendant 5 secondes.
2. L'écran affiche "PAS" puis, après un bref délai, 000.
3. Appuyez sur le bouton SC pour confirmer.
Vous êtes à présent dans le menu paramètres du contrôleur.
Pour modifier le mot de passe, vous devez aller dans les réglages des paramètres.
1. Saisissez le mot de passe actuel, tel qu'indiqué plus haut, et allez au menu.
2. Faites défiler jusqu'au groupe "ASi".
3. Appuyez sur le bouton SC pour confirmer.
4. Faites défiler jusqu'au paramètre "PS1" et appuyez sur le bouton SC pour confirmer.
5. Appuyez sur les boutons haut / bas pour saisir le mot de passe souhaité.
6. Appuyez sur le bouton SC pour confirmer.
Au bout de 30 secondes, l'écran affiche de nouveau automa­tiquement la température actuelle. Si ce n'est pas le cas,
Réglages des paramètres
appuyez deux fois sur le bouton dégivrage.
du contrôleur
Pour accéder aux réglages du contrôleur, vous devez saisir un mot de passe. Le niveau d'accès déterminera quels para­mètres vous pouvez voir et modifier.
Tableau 6. Liste des paramètres
Catégorie Abrév. Description To ut es
les portes simples
tHE Réglages du thermostat
SEt Point de consigne 5°C 5°C 5°C
SPr Réglage du point de consigne 0,2 °C 0°C 0°C
Tou te s les portes coulissantes
Tou s le s modèles à double et triple portes
diF Différentiel 1,1 °C 1,1 °C 1,1 °C
HSE Point de consigne haut 6°C 6°C 6°C
LSE Point de consigne bas 2°C 2°C 2°C
18 | Fonctionnement Réfrigérateurs de chromatographie et à usage général
Page 56
Tableau 6. Liste des paramètres
Catégorie Abrév. Description To ut es
les portes simples
dEF Réglages du dégivrage
dFt Type dégiv. nAt nAt nAt
Add Dégivrage adapté Oui Oui Oui
dtt Temp. fin dégiv. 4°C 4°C 4°C
drt Temp. réini. dégiv. 2°C 2°C 2°C
dii Intervalle min. dégiv. 1 heure 1 heure 1 heure
dAi Intervalle max. dégiv. 1 heure 1 heure 1 heure
dit Temps min. dégiv. 5 min 5 min 5 min
dAt Temps max. dégiv. 30 min 30 min 30 min
dot Temps d'écoulement 0 min 0 min 0 min
fdd
ftd Temp. démarrage des ventilateurs 10 °C 10 °C 10 °C
Temporisation des ventilateurs après dégivrage
0 sec 0 sec 0 sec
Tou te s les portes coulissantes
Tou s le s modèles à double et triple portes
dFa Ventilateur de dégivrage allumé Oui Oui Oui
dCt
doC
dEt Temp. évaporateur en dégiv. 0°C 0°C 0°C
ddt Delta T du dégivrage 3,0 k 3,0 k 3,0 k
idi Intervalle de dégivrage initial 0 heure 0 heure 0 heure
idd Durée de dégivrage initial 0 cycle 0 cycle 0 cycle
CoP Réglages du compresseur
uPt Protection de tension Non Non Non
uLi Tension de démarrage min. 0 V c.a. 0 V c.a. 0 V c.a.
uLo Tension d'arrêt min. 0 V c.a. 0 V c.a. 0 V c.a.
uHi Tension maximum 270 V c.a. 270 V c.a. 270 V c.a.
EHd Type d'erreur du capteur SEt SEt SEt
Ert Erreur temps de fonctionnement 10 min 10 min 10 min
ESt Erreur temps d'arrêt 7 min 7 min 7 min
Temps d'allumage compresseur en dégiv.
Temps de fonctionnement du comp. en dégiv.
Non Non Non
1 heure 1 heure 1 heure
CSt Temps d'arrêt min. 2 min 2 min 2 min
crt Temps de fonctionnement min. 2 min 2 min 2 min
Cot Temps d'arrêt max. 0 min 0 min 0 min
Réfrigérateurs de chromatographie et à usage général Fonctionnement | 19
Page 57
Tableau 6. Liste des paramètres
Catégorie Abrév. Description To ut es
les portes simples
Cdd Temporisation porte ouverte comp. 0 min 0 min 0 min
Srt Reprise système après porte ouverte 0 min 0 min 0 min
Pod Délai de mise sous tension 60 sec 60 sec 60 sec
Pot Température à la mise sous tension 16 °C 16 °C 16 °C
diS Réglages de l'écran
diC Contrôle auto intensité de l'écran Non Non Non
din Intensité de l'écran 8 8 8
CFu Unité écran C C C
trS Temp. capteur à l'écran Sco Sco Sco
rES Résolution de l'écran 1 1 1
rLT Limite écran Non Non Non
ddL Délai d'affichage 1 min 1 min 1 min
doF Décalage d'affichage 0,0 K 0,0 K 0,0 K
Tou te s les portes coulissantes
Tou s le s modèles à double et triple portes
dLt Temps de verrouillage après dégivrage 15 min 15 min 15 min
SEC Afficher le mode économie/nuit Non Non Non
SHo Afficher le mode vacances Non Non Non
Sdf Afficher le dégivrage Non Non Non
SCS Afficher le symbole compresseur Oui Oui Oui
SFS Afficher le symbole ventilateur Non Non Non
SdS Afficher le symbole dégivrage Non Non Non
SES Afficher le symbole ECO Non Non Non
idP Éléments affichés du menu Info 15 15 15
SSC Afficher fenêtre déroulante Non Non Non
ALA Réglages des alarmes
HAt Alarme temp. haute 10 °C 10 °C 10 °C
LAt Alarme temp. basse 2°C 2°C 2°C
Htd Temporisation de l'alarme temp. haute 0 min 0 min 0 min
Ltd Temporisation de l'alarme temp. basse 0 min 0 min 0min
dod Temporisation porte ouverte 1 min 1 min* 1 min
ACA Acquittement auto de l'alarme Oui Oui Non
Remarque : *les modèles à portes coulissantes de 1 274 litres ne sont pas équipés d'alarme porte entrouverte.
20 | Fonctionnement Réfrigérateurs de chromatographie et à usage général
Page 58

Entretien

Nettoyage de l'intérieur de l'armoire
AVERTISSEMENT:
de son alimentation principale avant de procéder à l'entretien de l'unité ou de ses commandes, sauf indication contraire.
Pour nettoyer l'intérieur de l'armoire, retirez les étagères, utili­sez une solution à base d'eau et de détergent doux. Rincez les composants de stockage intérieurs et essuyez-les à l'aide d'un chiffon doux.
débranchez l'équipement
Nettoyage de l'unité (réfrigérateurs de chromatographie)
Utilisez une solution à base d'eau et de détergent doux pour le nettoyage. Pulvérisez légèrement les composants de stoc­kage intérieurs et essuyez-les à l'aide d'un chiffon doux ou pulvérisez le chiffon en premier puis essuyez les surfaces inté­rieures.
Ne pulvérisez pas ou ne versez pas directement dans les trous et écarts du circuit de sécurité de chromatographie lors du nettoyage. Utilisez un chiffon humide pour nettoyer autour du boîtier du capteur et de la prise.
Si le voyant du capteur s'allume rouge après le nettoyage, réarmez manuellement le circuit de sécurité à l'aide de l'inter­rupteur de réarmement manuel situé à l'arrière de l'unité.
Pour nettoyer le condenseur, procédez comme suit :
1. Coupez l'alimentation.
2. Aspirez le condenseur et nettoyez toute la poussière.
3. Rétablissez l'alimentation.
Dégivrage automatique
Le processus de dégivrage de tous les modèles s'effectue principalement par la circulation de l'air lors des cycles d'arrêt. Ce processus sans chaleur permet d'éviter que la température soit affectée par le cycle de dégivrage. Le cycle de dégivrage fonctionne sur une méthode de dégivrage adap­tée qui est contrôlée par la température et le temps.
Lorsque le capteur de l'évaporateur descend en dessous de 0 °C, le cycle de dégivrage est lancé. Initialement, le cycle de dégivrage continue pendant au moins 5 minutes puis il se ter­mine une fois que la température du capteur de l'évaporateur atteint 4 °C. Si le capteur de l'évaporateur n'atteint pas la température de 4 °C dans les 30 minutes après le lancement du cycle de dégivrage, ce dernier se termine.
Entretien des joints d'étanchéité
Vérifiez régulièrement les joints autour de la porte pour détec­ter les crevaisons ou les déchirures. Les fuites sont repérables par de la condensation ou du givre qui se forme au point cri­tique du joint. Vérifiez que l'armoire est de niveau.
Veillez à ce que les joints d’étanchéité demeurent propres et sans givre en les essuyant délicatement avec un chiffon doux.
Nettoyage du condenseur
ATTENTION: nettoyez les condenseurs au
moins tous les six mois ; plus souvent si la zone du laboratoire est poussiéreuse. Dans les zones à trafic intense, les condenseurs se salissent plus rapidement. L'absence de nettoyage du conden­seur peut entraîner une surchauffe de l'équipe­ment ou des températures imprévisibles.
ATTENTION: ne nettoyez jamais autour du
condenseur avec vos doigts. Certaines surfaces sont tranchantes.
Le condenseur se situe sur la partie inférieure, à l'avant de l'unité.
Réfrigérateurs de chromatographie et à usage général Entretien | 21
Pour vérifier le joint de porte, procédez comme suit :
1. Ouvrez la porte.
2. Insérez une bande de papier (de 5 cm de largeur environ) entre le joint de porte et le rebord de l'armoire puis fermez la porte.
3. Tirez doucement sur la bande de papier depuis l'extérieur. Vous devriez ressentir une certaine résistance.
4. Répétez ce test tous les 10 cm tout autour de la porte. Si la porte ne se ferme pas correctement, remplacez le joint.
Page 59
Entretien de la pile de
Nettoyage de l'unité
l'alarme
L'unité est livrée avec (4) piles AA Alcaline de 1,5 V. La durée d'autonomie du système d'alarme à pile est de 60 heures. La pile doit être remplacée après une alarme active ou tous les 12 mois, selon ce qui arrive en premier.
Pour remplacer la pile, procédez comme suit :
1. Localisez la vis moletée/papillon située à gauche du panneau supérieur.
2. Retirez-la en la dévissant à la main.
(réfrigérateurs de chromatographie)
Utilisez une solution à base d'eau et de détergent doux pour le nettoyage. Pulvérisez légèrement les composants de stoc­kage intérieurs et essuyez-les à l'aide d'un chiffon doux ou pulvérisez le chiffon en premier puis essuyez les surfaces inté­rieures.
Ne pulvérisez pas ou ne versez pas directement dans les trous et écarts du circuit de sécurité de chromatographie lors du nettoyage. Utilisez un chiffon humide pour nettoyer autour du boîtier du capteur et de la prise.
Si le voyant du capteur s'allume rouge après le nettoyage, réarmez manuellement le circuit de sécurité à l'aide de l'inter­rupteur de réarmement manuel situé à droite du panneau supérieur.
Remplacement du capteur (réfrigérateurs de
3. Une fois les vis retirées, portez des gants et tirez doucement le support jusqu'à apercevoir complètement les piles.
4. Remplacez les piles et refermez doucement le support. Une fois le support fermé, alignez les trous sur le support et le panneau supérieur puis vissez à l'aide de la vis moletée/papillon.
chromatographie)
Le capteur doit être remplacé si la température descend en dessous de zéro à l'intérieur de l'armoire. Utilisez les alarmes du système pour vous assurer que la température à l'intérieur de l'unité reste au-dessus de 0 °C. Si l'unité est exposée au gel, le capteur doit être remplacé.
Si l'écran affiche une erreur et fait retentir une alarme (en cas de défaut de sonde d'une commande, du dégivrage, d'un fla­con ou de température ambiante), le capteur doit être rem­placé.
Entretien du capteur (réfrigérateurs de chromatographie)
Le capteur doit être remplacé tous les cinq ans par un presta­taire de services qualifié.
Préparation pour le stockage
Si l'unité doit être stockée en condition d'arrêt, laissez l'unité chauffer et sécher avec la porte ouverte avant de l'entreposer.
22 | Entretien Réfrigérateurs de chromatographie et à usage général
Page 60

Dépannage

AVERTISSEMENT: les procédures de dépan-
nage impliquent de sions qui peuvent causer des blessures ou la mort. Les services de dépannage doivent être assurés uniquement par du personnel agréé de l'usine.
Cette section vous guide dans le dépannage des problèmes de l'équipement. Les pièces doivent être remplacées uniquement par des pièces identiques.
Tableau 7. Procédure de dépannage
Problème Cause Solution
L'unité ne fonctionne pas ou le voyant de coupure de courant est allumé
travailler avec des hautes ten-
Alimentation électrique
Unité surchargée
Vérifiez que le câble est bien branché. Branchez un autre appareil sur la prise pour voir si cela fonc­tionne.
Testez la tension et vérifiez qu'elle est adaptée à votre unité.Vérifiez qu'il n'y a pas d'accumulation de givre sur les serpentins de réfrigération. Étei­gnez l'unité et laissez-la se dégivrer. Retirez les produits de l'étagère du haut de l'unité.
L'unité fonctionne constamment
La température de l'unité est trop élevée
La température fluctue/ refroidissement insuffisant
L'équipement est trop bruyant
Le réfrigérateur congèle Commande de température Réinitialisez la commande
L'unité chauffe
Condensateur sale Nettoyez le condenseur.
Réglage de la commande trop élevé
Circulation de l'air inadéquate Améliorez le mouvement de l'air. Commande de température Vérifiez que la commande est réglée correctement. Condenseur obstrué Vérifiez que le condenseur est propre.
Autres causes
L'équipement n'est pas de niveau
La porte est ouverte Vérifiez que la porte est bien fermée. Vérification du joint de porte Vérifiez le point de la porte. Produit chaud placé récemment à
l'intérieur de l'unité
Alimentation électrique
Le compresseur ne fonctionne pas
Réinitialisez la commande
Si la commande de température est réglée correc­tement et si le condenseur est propre mais que la température continue de fluctuer, appelez un représentant d'entretien agréé.
Placez l'équipement sur une surface de niveau ou utilisez un pied réglable.
Laissez le temps à l'unité de revenir à la tempéra­ture.
Vérifiez la tension de l'unité. En l'absence de ten­sion au niveau de l'unité, appelez un électricien.
Si le compresseur ne fonctionne pas et que l'alarme sonore d'alimentation est allumée, demandez à un électricien de vérifiez la tension de l'unité.
Si le compresseur ne fonctionne pas et que l'alarme coupure de courant est éteinte, appelez le service clients pour obtenir de l'aide.
Unité bruyante Pièces ou fixations desserrées Serrez.
Réfrigérateurs de chromatographie et à usage général Dépannage | 23
Page 61

Soins de Fin de vie

Veillez à respecter les réglementations locales lors de l'élimi­nation d'une ancienne unité. Voici quelques suggestions :
1. Retirez les articles et dégivrez l'unité. Veillez à nettoyer tout produit présentant un risque biologique.
2. Retirez la porte de l'armoire afin d'éviter qu'une personne ne se retrouve enfermée à l'intérieur de l'unité.
3. Demandez à un technicien certifié de retirer le réfrigérant et le compresseur, puis vidangez l'huile du compresseur du système. Jetez les composants conformément aux réglementations locales.
24 | Soins de Fin de vie Réfrigérateurs de chromatographie et à usage général
Page 62

Garantie

Garantie nationale • 24 mois sur les pièces et la main d'œuvre, 5 ans sur le compresseur Garantie internationale • 24 mois sur les pièces Au cours des vingt-quatre (24) premiers mois à compter de l'expédition, Thermo Fisher Scientific Inc, par l'intermédiaire de son
distributeur agréé ou d'organismes de services, réparera ou remplacera, à sa discrétion et à ses frais, toute pièce présentant un vice de matière ou de fabrication. Thermo Fisher Scientific Inc se réserve le droit d'utiliser des pièces de rechange, qui sont d'occasion ou reconditionnées. Les pièces de rechange ou réparées seront garanties pendant uniquement pour la durée res­tante de la garantie d'origine.
La présente garantie ne s'applique pas aux dommages causés par (i) un accident, une mauvaise utilisation, un incendie, une inondation ou des cas de force majeure ; (ii) une installation, un fonctionnement ou une maintenance non appropriés des pro­duits, conformément aux consignes imprimées fournies ; (iii) des causes externes aux produits comme, notamment, une panne d'électricité ou des surtensions électriques ; (iv) un stockage et une manutention inappropriés des produits ; (v) une utilisation des produits avec un équipement ou un logiciel non fourni par Thermo Fisher ; ou (vi) une installation, une maintenance, une réparation, un service, un déplacement ou une modification des produits par une personne autre que Thermo Fisher ou son représentant agréé. Pour bénéficier d'un service sous garantie, contactez le centre de services ou le distributeur agréé le plus proche. Les registres d'expédition de Thermo Fisher Scientific, Inc indiquant la date d'expédition sont déterminants pour la constatation de la période de garantie. Sur décision de Thermo Fisher, toutes les pièces non conformes doivent être renvoyées à Thermo Fisher, port prépayé, et les pièces de rechange sont expédiées franco à bord à Thermo Fisher.
Limitation de responsabilité : LA PRÉSENTE GARANTIE EST EXCLUSIVE ET REMPLACE TOUTE AUTRE GARANTIE ÉCRITE, ORALE OU IMPLICITE. LA
SOCIÉTÉ N'ACCORDE AUCUNE GARANTIE DE QUALITÉ MARCHANDE OU DE CONVENANCE À UN USAGE PARTICULIER. THERMO FISHER NE GARANTIT PAS QUE SES PRODUITS SONT EXEMPTS D'ERREUR NI QU'ILS ATTEINDRONT UN RÉSULTAT PARTICULIER.
THERMO FISHER NE PEUT ÊTRE TENUE POUR RESPONSABLE DE DOMMAGES INDIRECTS OU CONSÉCUTIFS, Y COM­PRIS, NOTAMMENT, DE DOMMAGES POUR PERTES DE BÉNÉFICES OU PERTE DE PRODUITS.
Réfrigérateurs de chromatographie et à usage général Garantie | 25
Page 63

Conformité réglementaire

Sécurité des produits
Essais des produits
Cette famille de produits a été testée selon les normes de sécurité des produits applicables par Underwriters Laboratories (UL), un laboratoire d'essais reconnu au niveau national (Nationally Recognized Test Laboratory
- NRTL).
Réfrigérants à base d'hydrocarbures
Conformément au code des règlements fédéraux américain 40 Partie 82, ce réfrigérateur utilise le réfrigérant à base d'hydro­carbure naturel R290. En raison de la nature des réfrigérants à base d'hydrocarbures, toute réparation mécanique, comme une recharge ou le remplacement du compresseur, doit être réalisée uniquement par un technicien de réfrigération certifié. La sécu­rité de cet équipement est citée par Underwriter Laboratory (UL) en vertu de la norme UL471, section SB, - "natural refrigerant" ("réfrigérant naturel").
Compatibilité électromagnétique
Déclaration de la FCC (États-Unis)
Toute transformation ou modification apportée à l'appareil sans l'autorisation expresse de la partie responsable de sa conformité pourraient faire perdre à l'utilisateur son droit à l'utiliser.
Remarque : Cet équipement a été testé et déclaré conforme aux limites pour appareils numériques de Classe A, selon la partie 15 des réglementations de la FCC. Ces limites sont destinées à assurer une protection raisonnable contre les interférences nuisibles lorsque l'équipement fonctionne dans une installation commerciale. Cet équipement produit, utilise et peut émettre de l'énergie radio électrique et, s'il n'est pas installé et utilisé conformément au mode d'emploi, peut causer des interférences nuisibles aux communications radio. Le fonctionnement de cet équipement dans une zone résidentielle peut causer des interférences nuisibles. Dans ce cas, l'utilisateur devra corriger ces interférences à ses propres frais.
Avis ISDE IC au Canada
This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada.
26 | Conformité réglementaire Réfrigérateurs de chromatographie et à usage général
Page 64
Rendement énergétique
ENERGY STAR
Cette famille de produits a été évaluée volontairement et estimée conforme par un organisme de certification approuvé par EPA selon la spécification relative aux réfrigérateurs et congélateurs de laboratoire 1.1 de EPA ENERGY STAR.
Autres réglementations et marquages
Ce produit ne possède pas le marquage CE car il ne fonctionne pas dans une plage de tension adaptée à la vente aux États membres de l'UE ou de l'Espace économique européen (EEE). Veuillez contacter le fabricant pour toute question relative à la conformité à d'autres réglementations.
Réfrigérateurs de chromatographie et à usage général Conformité réglementaire | 27
Page 65
Conformité DEEE
Great Britain
Deutschland
Italia
France
WEEE Compliance. This product is required to comply with the European Union’s Waste Electrical &
Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked with the following symbol. Thermo Fisher Scientific has contracted with one or more recycling/disposal companies in each EU Member State, and this product should be disposed of or recycled through them.
WEEE Konformittät. Dieses Produkt muss die EU Waste Electrical & Electronic Equipment (WEEE) Richtlinie 2012/19/EU erfüllen. Das Produkt ist durch folgendes Symbol gekennzeichnet. Thermo Fisher Scientific hat Vereinb Mitgliederstaaten und dieses Produkt muss durch diese Firmen widerverwetet oder entsorgt werden.
arungen getroffen mit Verwertungs-/Entsorgungsanlagen in allen EU-
Conformità WEEE. Questo prodotto deve rispondere alla direttiva dell’Unione Europ in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici (WEEE). È marcato col seguente simbolo. Thermo Fisher Scientific ha stipulato contratti con una o diverse società di riciclaggio/smaltimento in ognuno degli Stati Membri Europei. Questo prodotto verrà smaltito o riciclato tramite queste medesime.
Conformité DEEE. Ce produit doit être conforme à la directive européenne (2012/19/EU) relative aux Déchets d'Équipements Électriques et Électroniques (DEEE). Il présente le symbole suivant. Thermo Fisher Scientific s’est associé à une ou plusieurs entreprises d de l’Union européenne. Ce produit doit donc être collecté ou recyclé par celles-ci.
e recyclage dans chaque État membre
ea 2012/19/EU
Page 66
BESOIN D'ASSISTANCE :
Les produits de Thermo Fisher Scientific bénéficient d'une équipe d'assistance technique internationale à votre disposition. Nous proposons des accessoires pour le stockage frigorifique, notamment des alarmes à distance, des enregistreurs de température et des services de validation. Rendez-vous sur www.thermofisher.com/cold ou composez le :
Pays Ventes
Amérique du Nord +1 866 984 3766
Inde, numéro gratuit 1800 22 8374
Inde +91 22 6716 2200
Chine +800 810 5118, +400 650 5118
Japon +81 3 5826 1616
Australie +61 39757 4300
Autriche +43 1 801 40 0
Belgique +32 53 73 42 41
France +33 2 2803 2180
Allemagne international +49 6184 90 6000
Allemagne, numéro national gratuit 0800 1 536 376
Italie +32 02 95059 552
Pays-Bas +31 76 579 55 55
Pays nordiques/baltes/Communauté des États indépendants
Russie +7 812 703 4215
Espagne/Portugal +34 93 223 09 18
Suisse +41 44 454 12 22
RU/Irlande +44 870 609 9203
Nouvelle Zélande +64 9 980 6700
Autres pays asiatiques +852 2885 4613
Pays non cités +49 6184 90 6000
+358 9 329 10200
Thermo Fisher Scientific Inc. 275 Aiken Road Asheville, NC 28804 États-Unis
Pour en savoir plus, rendez-vous sur thermofisher.com/cold
© 2018 Thermo Fisher Scientific Inc. Tous droits réservés. Toutes les marques déposées appar­tiennent à Thermo Fisher Scientific et à ses filiales, sauf indication contraire. 329137H01 0818
Loading...