Thermo Scientific S1 Instructions For Use Manual

1
Thermo Scientific S1 Pipet Filler
Instructions for Use Guide d´utilisation Bedienungsanleitung
取扱説明書
说明书
WEEE Compliance:
This product is required to comply with the European Union’s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. It is marked with the following symbol:
Thermo Fisher Scientific has contracted with one or more recycling/disposal companies in each EU Member State, and this product should be disposed of or recycled through them. Further information on Thermo Fisher Scientific’s compliance with these Directives, the recyclers in your country, and information on Thermo Scientific products which may assist the detection of substances subject to the RoHS Directive are available at www.thermo.com/WEEERoHS
Conformité WEEE:
Ce produit doit être conforme à la directive européenne (2002/96/EC) des Déchets d’Equipements Electriques et Electroniques (DEEE). Il est marqué par le symbole suivant:
Thermo Fisher Scientific s’est associé avec une ou plusieurs compagnies de recyclage dans chaque état membre de l’union européenne et ce produit devrait être collecté ou recyclé par celles-ci. Davantage d’informations sur la conformité de Thermo Fisher Scientific à ces directives, les recycleurs dans votre pays et les informations sur les produits Thermo Scientific qui peuvent aider la détection des substances sujettes à la directive RoHS sont disponibles sur www.thermo.com/WEEERoHS
WEEE Konformität:
Dieses Produkt muss die EU Waste Electrical & Electronic Equipment (WEEE) Richtlinie 2002/96/ EC erfüllen. Das Produkt ist durch folgendes Symbol gekennzeichnet:
Thermo Fisher Scientific hat Vereinbarungen getroffen mit Verwertungs- / Entsorgungs-anlagen in allen EU-Mitgliederstaaten und dieses Produkt muss durch diese Firmen wiederverwertet oder entsorgt werden. Mehr Informationen über die Einhaltung dieser Anweisungen durch Thermo Fisher Scientific, die Verwerter und Hinweise die Ihnen nützlich sein können, die Thermo Scientific Produkte zu identifizieren, die unter diese RoHS Anweisung fallen, finden Sie unter www.thermo.com/WEEERoHS
Product specifications are subject to change without prior notice. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. See the latest version at www.thermoscientific.com
Les spécifications des produits peuvent être modifiées sans préavis. Voir la dernière version sur www.thermoscientific.com
Änderung von Produktbeschreibungen ist vorbehalten ohne vorherige Benachrichtigungt. Sehen Sie die neueste Version an www.thermoscientific.com
3
II
ENGLISH..............................................................................3-7
FRANÇAIS ........................................................................8-12
DEUTSCH ........................................................................13-17
..............................................................................18-22
................................................................................23-27
..................................................................................28-32
4-8
14-18
19-23
29-33
24-28
9-13
4-8
14-18
19-23
29-33
24-28
9-13
Thermo Scientific S1 Pipet Filler
4
DISPENSE TRIGGER
ASRIRATE TRIGGER
1mL PIPET SUPPORT RECHARGE SOCKET
FILTER
NOSEPIECE
PIPET GRIPPER
PERSONALIZED NAME CARD
INDEPENDENT PUSH BUTTON CONTROLS for aspiration and dispense speeds.
MANY USEFUL ACCESSORIES are included to provide for your specific applications. See inside for details.
HANDLE AND TRIGGERS are ergonomically designed for comfortable, fatigue-free use.
ILLUMINATED LCD DISPLAY shows battery charge, pump speed for aspiration, pump speed for dispensing, and low battery warning.
Pipettor Overview
Thermo Scientific S1 Pipet Filler
5
Congratulations!
You have purchased a lightweight, compact, cordless Thermo Scientific S1 Pipet Filler. Designed for use with graduated and volumetric glass and plastic pipets, S1Pipet Filler offers simple, efficient pipetting performance and maximum pipetting comfort.
Operating on a heavy-duty, rechargeable lithium-ion battery, this pipettor can operate approximately 3 to 4 times longer between charges than typical units using nickel cadmium batteries.
Before You Begin
Included in this S1 Pipet Filler package, you should find the following:
• Thermo Scientific S1 Pipet Filler
• Power Supply (for charging battery
or for use with AC current)
• Wall-Mounted Holder
• Table-Mounted Stand
• Pipet Support to
Eliminate Wobble with 1mL Pipets
• Name Cards and Clear Covers for Personalizing Your S1 Pipet Filler
• Certificate of Warranty and Warranty Registration Card
• Power Adapters for International Use
If you are missing any of the above items, please contact your Thermo Scientific representative.
Thermo Scientific S1 Pipet Filler: Cordless Pipettor
With Advanced Solid State Technology
6
Charging/Recharging
Warning: Use only the original Thermo
Scientific S1 Pipet Filler charger and battery pack.
The pipet filler battery may be discharged when delivered and must be charged before initial use. Insert the country specific power plug adapter into the power supply unit. Plug the power supply into the recharge socket at the base of the pipettor’s handle and the other end to an AC wall socket. Allow the unit to charge anywhere from 15minutes to 2hours. To extend the
battery life cycle, it’s recommended to charge the pipet filler every two months even if it is not used on a daily basis. A typical S1 Pipet Filler battery lasts for approximately 400charging cycles. Please note that a depleted battery can cause the pipette to malfunction. We recommend that at a minimum you should change the battery every 3years. For added
ease and convenience, S1Pipet Filler features:
• A battery icon on the LCD display that indicates the level of battery charge -­the more bars, the greater the charge.
• Special circuitry that makes it impossible to overcharge the battery and that allows the pipettor to be charged or partially charged at any convenient time.
Using S1 Pipet Filler
To use your S1 Pipet Filler, insert a pipet securely in the holder and follow these simple directions:
To Aspirate
Insert the pipet into your sample and depress the upper trigger.
To Dispense
Insert the pipet into your chosen vessel and depress the lower trigger. (Partially depressing the trigger allows for controlled gravity dispensing.)
To Set The Pump Speed
Buttons on the rear of your S1 Pipet Filler unit allow you to set your aspiration (upper button) and dispense (lower button) speeds. Eight speeds are available for each function – simply push “+” for faster and “-” for slower. Your selection will be displayed on the lower portion of the pipettor’s LCD. A zero speed selection on dispense enables gravity dispensing.
Disinfecting And Disassembling
The entire S1 Pipet Filler can be cleaned with most common laboratory disinfectants but must not be submerged in liquid. To prepare the unit for cleaning:
• Remove the nosepiece by turning the housing in a counterclockwise direction.
• Remove the silicone rubber pipet gripper from the nosecone. Pipet gripper and nosecone may be autoclaved.
Air Filter
Aspiration rate slowing may be a sign that the air filter needs replacing. To do so, remove the nosepiece and pipet gripper, pull the filter firmly and wiggle to remove from body.
Thermo Scientific S1 Pipet Filler
7
Wall Attachment
The enclosed S1 PipetFiller wall mount may be attached to a smooth, clean surface using the adhesive backing (also included). For best results, wipe the wall surface with alcohol, let dry, press wall mount firmly in place and allow to set overnight before using. For rough surfaces, mount with screws.
1mL Pipet Support
To enhance pipetting performance when using 1mL pipets, S1 Pipet Filler features a unique pipet support. Simply snap the accessory into the nosecone housing, insert your pipet, and perform your chosen application with a stable, wobble-free pipet.
Power Requirements
Environmental Operating Conditions
For optimum performance, your S1 Pipet Filler should be used under the following range of conditions:
Operating altitude 0-1,524m Operating temperature 10-35°C Relative humidity 10-95% non-condensing Mains supply voltage fluctuations
(for external power supply) 90V AC or 264V AC Transient overvoltage
(for the power supply)
Installation Category II
Applicable rated pollution degree
Pollution Degree 2 (normally only non­conductive pollution occurs)
EXPLANATION OF SYMBOLS ON POWER SUPPLY
= DC Symbol = For Indoor Use Only = Class 2 Power Supply
Power supply input 100V AC or 240V AC,
50-60 Hz, 0.2A
Power supply output 6.0V DC, 0.5A,
Constant Current
Power Requirements
EXPLANATION OF SYMBOLS ON POWER SUPPLY
= DC Symbol = For Indoor Use Only = Class 2 Power Supply
Power supply input 100V AC or 240V AC,
50-60 Hz, 0.2A
Power supply output 6.0V DC, 0.5A,
Constant Current
Power Requirements
EXPLANATION OF SYMBOLS ON POWER SUPPLY
= DC Symbol = For Indoor Use Only = Class 2 Power Supply
Power supply input 100V AC or 240V AC,
50-60 Hz, 0.2A
Power supply output 6.0V DC, 0.5A,
Constant Current
Power Requirements
Power Requirements
8
Thermo Scientific S1 Pipet Filler
Hazards And Precautions
There are no known hazards associated with the S1 Pipet Filler when it is operated in accordance with the instructions in this manual. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Technical Information
For technical assistance or to reorder, contact your nearest Thermo Scientific representative. See back cover for details.
S1 Pipet Filler models and Accessories
Item No. Description Unit
95* S1 Pipet Filler 1 9066 Single Pipet Filler Wall Mount Stand 1 9067 Single Pipet Filler Table Mount Stand 1 9069 Single Pipet Filler Wing Stand** 1 9065 Silicone Pipet Gripper 4/case 9070 1 ml Pipet Filler Support 1 9068 Power Supply (Universal Input) 1 9057 Hydrophobic Filters, 0.45 µm, Sterile 25/box 4580560 Hydrophobic filters, 0.45 µm, Non-Sterile 5/bag 9064 Nosepiece (holder, silicone gripper, filter) 1
*Available Colors: 01 = White, 11 = Clear, 21 = Blue, 31 = Red, 41 = Green **Not available for use or sale within the United States or for importation into the United States.
9
Thermo Scientific S1 Pipet Filler
SUPPORT PIPETTE 1mL PRISE DE RECHARGE
FILTRE
RACCORD
DISPOSITIF DE PRÉHENSION DE LA PIPETTE
ÉTIQUETTE D’IDENTIFICATION PERSONNALISÉE
BOUTONS-POUSSOIRS INDÉPENDANTS pour régler les vitesses d’aspiration ou de distribution.
DE NOMBREUX ACCESSOIRES UTILES sont inclus pour permettre différentes applications. Voir à l’intérieur pour de plus amples détails.
AFFICHAGE À CRISTAUX LIQUIDES affiche le niveau de chargement de la batterie, la vitesse d’aspiration ou de distribution de la pompe ainsi qu’un message d’avertissement si les batteries sont épuisées.
Aperçu du pipeteur
LES DÉCLENCHEURS ET LES POIGNÉES sont ergonomiques pour un plus grand confort d’utilisation et moins de fatigue.
DÉCLENCHEUR DE DISTRIBUTION
DÉCLENCHEUR D’ASPIRATION
10
Félicitations!
Vous venez d'acheter le Thermo Scientific S1Pipet Filler, un remplisseur de pipettes léger, compact et sans fil. Conçu pour être utilisé avec des pipettes en verre ou en plastique graduées et volumétriques, le S1Pipet Filler associe performances et confort d'utilisation.
Grâce à une batterie au lithium-ion puissante et rechargeable, la durée de fonctionnement de ce pipeteur est 3 à 4 fois supérieure à celle des dispositifs classiques dotés de batteries au cadmium-nickel.
Avant de commencer
Les éléments suivants sont compris dans l'emballage du S1 Pipet Filler:
• Thermo Scientific S1 Pipet Filler
• Socle d'alimentation (recharge batterie
ou utilisation du secteur)
• Support pour montage mural
• Pied pour montage sur table
• Adaptateur pour pipette 1 mL (pour éliminer les tremblements)
• Étiquettes d’identification et protections transparentes pour personnaliser votre S1 Pipet Filler
• Certificat de garantie et carte de garantie
• Adaptateur secteur universel
Si l'un des éléments ci-dessus venait à manquer, veuillez contacter votre représentant Thermo Scientific.
Thermo Scientific S1 Pipet Filler: pipeteur sans fil doté
d’une technologie à semi-conducteurs de pointe
11
Chargement/rechargement
Avertissement: N'utiliser que le chargeur et la batterie Thermo Scientific S1 Pipet Filler d'origine.
La batterie du remplisseur de pipettes peut être totalement épuisée à la livraison et doit donc être rechargée avant toute première utilisation. Choisissez l'adaptateur secteur adapté à votre pays. Raccordez le câble d'alimentation à la prise de recharge située sous la poignée de la pipette et à une prise secteur murale. Laissez l'instrument en charge entre 15minutes et 2heures.
Pour augmenter la durée de vie de la batterie, il est recommandé de recharger le remplisseur de pipettes tous les deux mois même s'il n'est pas utilisé quotidiennement. En général, la batterie du S1 Pipet Filler permet d'assurer environ 400cycles de recharge. Veuillez noter qu'une batterie faible peut entraîner des dysfonctionnements de l'instrument. Il est recommandé de remplacer la batterie au moins une fois tous les 3ans.
Fonctions du S1Pipet Filler:
• Une icône sur l'affichage à cristaux liquides indique le niveau de charge de la batterie: plus il y a de segments et plus la batterie est pleine.
• Une circuiterie spéciale empêche de surcharger la batterie et permet une recharge complète ou partielle du pipeteur à tout moment.
Utilisation du S1 Pipet Filler
Pour utiliser votre S1 Pipet Filler, insérez une pipette dans le raccord et suivez simplement ces instructions:
Aspiration
Trempez la pipette dans votre échantillon et appuyez sur le déclencheur du haut.
Distribution
Insérez la pipette dans le récipient de votre choix et appuyez sur le déclencheur du bas (en appuyant partiellement sur le déclencheur, vous obtenez une distribution par gravité contrôlée).
Réglage de la vitesse de la pompe
Les boutons situés à l’arrière de votre S1Pipet Filler permettent de régler les vitesses d’aspiration (bouton du haut) et de distribution (bouton du bas). Chaque fonction dispose de huit vitesses. Appuyez simplement sur le signe «+» pour augmenter la vitesse et sur le signe «-» pour la réduire. La vitesse sélectionnée s’affiche ensuite au bas de l’affichage à cristaux liquides. Une vitesse de distribution zéro active la distribution par gravité.
Désinfection et démontage
Le S1 Pipet Filler peut être entièrement nettoyé à l'aide des désinfectants de laboratoire les plus courants, mais ne doit jamais être immergé. Préparation de l'instrument pour le nettoyage:
• Retirez le raccord en le tournant dans le sens inverse des aiguilles d'une montre.
• Retirez le dispositif de préhension en silicone du raccord. Ces deux éléments peuvent être autoclavés.