Thermo Scientific Lindberg/Blue M VO Series, Lindberg/Blue M VO914, Lindberg/Blue M VO1218, Lindberg/Blue M VO1824 Installation And Operating Manual

f
\
Thermo Fisher Scientific
LindbergIBlue M Vacuum Ovens
V0914 I V01218 I V01824
Installation and Operating Manual
34598H19
E
11/2011
\
/
Part of Thermo Fisher Scientific
Therrno
SCIENTIFIC
© 2
011 Thermo Fisher Scientific Inc. All rights reserved.
These operating instructions are protected by copyright. Rights resulting thereof, particularly reprint, photomechanical or digital
post processing or reproduction, even in part, are only allowed with the written con
sent of Thermo Fisher Scientific Inc. This regulation does not apply to reproductions for in-plant use. The contents of this operating instructions manual may change at any time and without a
ny prior notice. In case of conflicting translations into foreign languages the German-language version of these operating instructions shall be binding.
Trademarks
Thermo Scientific is a brand owned by Thermo Fisher Scientific, Inc. Lindberg Blue M® and a
ll other trademarks
mentioned in the operating instructions are the exclusive property of the
respective manufacturers. Thermo Fisher Scientific Inc.
275 Aiken Road Asheville, NC 28804 USA
Thermo Fisher Scientific Inc. 8
1 Wyman Street Waltham, MA 02454 USA
Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. This document is copyright protected and any reproduction of the whole or any part of this d
ocument is
strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc. The contents of this document are subject to change without notice. All technical information in this document is for
reference purposes only. System con
figurations and specifications in this document supersede all previous
information received by the purchaser.
Thermo Fisher Scientific Inc. makes no representations that this document is complete, accurate or error-free and assumes no responsibility and w
ill not be liable for any errors, omissions, damage or loss that might
result from any use of this document, even if the information in the document is followed properly.
This document is not part of any sales contract between Thermo Fisher Scientific Inc
. and a purchaser. This document shall in no way govern or modify any Terms and Conditions of Sale, which Terms and Conditions of Sale shall govern all conflicting information between the two documents.
Laboratory Vacuum
Ovens
6
Operation
.
UP150
Controller ("P" Models only)
........................................
8
6.1 Normal Controller Operation
................................................................
8
6.2 Single Setpoint Operation
..................................................................
9
6.2.1 Setting High Temperature Alarm Setpoint:
...............................................
9
6.2.2 AccessingLocalMode
..............................................................
9
6.2.3 ExitingLocalMode
.................................................................
9
..................................................
6.3 Programming Operation: Entering a Program
9
6.3.1 Entering Programming Mode
.........................................................
9
6.3.2 Entering Program Parameters
.......................................................
10
6.3.3
RunningaProgram
................................................................
11
.................................................................
6.3.4 EndingaProgram
11
6.3.5 ChangingaProgram
...............................................................
11
6.4 Auto Tuning the UP1 50 Controller
..........................................................
11
6.5 Temperature Offset Procedure
.............................................................
12
6.6 Changing Temperature Scale Between
C
and
T
..............................................
12
7
Maintenance
.....................................................................
13
7.1 GeneralMaintenance
....................................................................
13
7.2
GasketMaintenance
.....................................................................
13
7.3
DoorAlignment
.........................................................................
13
..................................................................
8
Troubleshooting
14
9
Replacementparts
................................................................
15
Installation and Operation
Laboratory Vacuum Ovens
1
Introduction
The LindbergIBlue M VO
Series is a family of laboratory vacuum ovens designed for drying, curing, outgassing, process control, and applications which require elevated temperature in reduced atmospheres or
vacuudpurge with non-flammable
gases. Refer to Table
1
on page 2 for specifications.
1.1
Features and Benefits
Single setpoint digital electronic control (models with suffix
P
have programmable controls).
Built
-
in overtemperature protection.
Fully flexible
vacuudpurge/release system.
Vacuum system includes inert gas injection valve, fresh air inlets, vacuum port to exhaust vacuum atmosphere, and controllable vacuum release vent port.
1.2
Available Door Gaskets
In addition to the standard silicone gasket provided with the oven, the following gaskets are available from
LindbergIBlue
M:
Buna-N gasket for use with solvents up to
160°C.
Viton-B gasket for applications involving acids.
Refer to Table
7
on page 15 for gasket ordering information.
Installation and Operation
Laboratory Vacuum Ovens
1.3
Specifications
Table
1.
Lindbergmlue M VO Series Laboratory Vacuum Ovens
2
Safety
Considerations
Model
V0914(P)A
VO914(P)C
V01218(P)A
VO1218(P)C
V01824(P)A
VO1824(P)C
V0914S(P)A
V0914S(P)C
V01218S(P)A
VOIZI8S(P)C
V0 1824S(P)A
V01824S(P)C
WARNING!
Do not modify or change system
components. Replacement parts must be
OEM.
exact replacement equipment. Modification or use of the equipment in a manner other than expressly intended may cause death or serious injury. This includes use of user
-
supplied components and materials not specifically designed for the oven. Reconfiguring the controller may cause death or serious injury.
LindbergIBiue M shall not be liable for any damages,
including incidental
and/or consequential damages,
regardless of the legal
theoty asserted, including
negligence
and/or strict liability.
WARNING1 Before maintaining this equipment,
read the applicable MSDS (Material Safety Data Sheets) provided with your oven.
Chamber
9x14~9
(22.9 X 35.6 X 22.9)
12x 18x 12
(30.5 x 45.7 x 30.5)
18 x 24 x 18
(45.7 X 61 X 45.7)
9x14~9
(22.9 X 35.6 X 22.9)
12x18~12
(30.5 x 45.7 x 30.5)
18 x 24 x 18
(45.7
X
61 X 45.7)
WARNING! This unit is not intended for use in processing hazardous work loads. Fatal injuries and property damage can result from processing combustible volatile fluids or materials which emit explosive vapors.
Voltage
120 VAC, 50160
Hz,
Single Phase
240
VAC,
50160
H~,
Single Phase
120 VAC, 50160
Hz,
Single Phase
240 VAC, 50160
Hz,
Single Phase
120 VAC, 50160
Hz,
Single Phase
240
VAC,
50160
H~,
Single Phase
120 VAC, 50160
Hz,
Single Phase
240
VAC,
50160
H~,
Singie Phase
120 VAC, 50160
Hz,
Single Phase
240 VAC, 50160
Hz,
Single Phase
120 VAC, 50160
Hz,
Single Phase
240
VAC,
50160
H~,
Single Phase
Do not use combustible gases in this oven.
Dimensions W x
F-B x H
Exterior
17.5 x 20 x 24.7
(44.5
X
50.8 X 62.7)
20.5 x 23 x 28.4
(52 x 58.4 x 72.1)
26.3
x
30.4 x 34.3
(66.8
X
77.2 X 87.1)
17.5 x 20 x 24.7
(44.5
X
50.8 X 62.7)
20.5 x 23 x 28.4
(52 x 58.4 x 72.1)
26.3 x 30.4 x 34.3
(66.8
X
77.2 X 87.1)
Avoid combustible products which generate toxic or hazardous vapor or fumes. Work should only be done in a properly vented environment.
Exterior
Enameled
Steel
Stainless
in.
(cm)
Shipping
(Approximate)
27.5 x 30 x 34.7
(69.8
X
76.2 X 88.1)
30.5 x 33 x 38.4 (77.5 x 84
x
98)
36x41
x45
(91.5 X 104.1 X 114.3)
27.5 x 30 x 34.7
(69.8
X
76.2 X 88.1)
30.5 x 33 x 38.4 (77.5 x 84 x 98)
27.5 x 30 x 34.7
(69.8
X
76.2 X 88.1)
Before using, user shall determine the suitability and
integrity of the product for the intended use and that the unit has not been altered in any way. User assumes all risk and liability whatsoever therewith.
Heater
Power
(kw)
1.05
.55
1.55
1.05
.55
1.55
Shipping
Weight
Ibs
(kg)
150
(68)
250
(114)
325
(148)
150
(68)
250
(114)
325
(1 48)
Installation and Operation
Laboratory Vacuum Ovens
Figure
1.
Vacuum and Gas Connections
114" Gas
inlet
07
vacuum por~
114" Vent port
I
Vent Gas Vacuum
.
1
-
.
-
-
1
-
I
1
-
-
1
-
.
1
-
I
-
-
-
-
.
-
CAUTION!
This product contains fiberglass wool or
other refractories which can result in the following:
1" NPTvacuum port
-
May be irritating to skin, eyes, and respiratory tract. May be harmful if inhaled.
Possible cancer hazard based on tests with
laboratoly animals. Animal studies to date are
inconclusive. No human exposure studies with this product have been reported.
-
-
-
-
-
-
I
WARNING! Before maintaining this equipment, read the applicable MSDS (Material Safety Data Sheets) at the back of this manual.
Dl
.
-
1
I
-
-
1
1
.
1
-
-
Power cord
?,-;
-
.
Overtemperature reset button
WARNING! When installing, maintaining, or removing the refractory insulation. the following precautions will minimize airborne dust and fiber:
Keep personnel not involved in the installation out of the area. Use a good vacuum to clean area and equipment. Use a dust suppressant if sweeping is necessary. Do
not
use compressed air. Use disposable mask suitable for nuisance dust. Wear long sleeve clothing, gloves, hat, and eye protection to minimize skin and eye contact. Do not wear contact lenses. Thoroughly wash self after work is complete. Launder work clothing separate from other clothes and thoroughly clean laundering equipment after use. If clothing contains a large amount of dust
andlor fiber, dispose of rather than clean.
Promptly place used fiberglass parts and dust in plastic bags and dispose of properly.
Note:
Since
the
front
panel
display
reads
gauge
pressure
the
value
is
relative
to the
local
atmospheric
pressure.
Use
in a location
with
reduced
atmospheric
pressure
will
result
in
the
gauge
displaying
diminished
vacuum
levels.