Thermo Scientific iCAP TQe ICP-MS
Redefining triple quadrupole ICP-MS
with unique ease of use
iCAP TQe ICP-MS
Overcome unexpected interferences, reduce detection
limits for critical contaminants and improve data quality
Leverage superior interference removal using triple
quadrupole (TQ) ICP-MS for uncomplicated analysis
with incredible accuracy. Expand your applications and
enhance your laboratory eciency with this breakthrough
technology, which is so easy to use that it can be
operated by any analyst.
• Reaction Finder method development assistant
enables you to tackle challenging matrices without
complex, time-consuming method development
• Common Thermo Scientific™ Qtegra™ Intelligent
Scientific Data Solution™ (ISDS) software platform allows
analysts to switch easily between ICP techniques
• Minimal installation and bench space requirements
The Thermo Scientific
optimal solution for future-proofing elemental analysis
in your laboratory, explore developing markets,
increase productivity and meet the requirements
of evolving legislation.
• Right-first-time analysis with powerful interference
removal, even in the toughest matrices
• Reduced re-runs in the daily workload with assured
accuracy and repeatability
• Maintained flexibility of single quadrupole
(SQ) mode for less challenging analyses
™
iCAP™ TQe ICP-MS is the
2
For applied testing
Robust and easy to use, the iCAP TQe ICP-MS is a
compact and low maintenance instrument. Daily analysis
is elevated to a new level and the high matrix tolerance
and exceptional interference removal, even in challenging
sample matrices, open up new applications. Simplified
operation from Qtegra ISDS software means operators
do not need to be specialists.
For research
Improved interference removal leads to the lower
detection limits that are essential for new scientific
breakthroughs. Find out what is possible with the
advanced performance of TQ-ICP-MS technology.
3
Inside TQ technology
Highly eective interference removal for accurate
and reliable results
• The iCAP TQe ICP-MS achieves consistent interference
removal regardless of the sample composition using
just helium and oxygen as the collision/reaction cell
gases. This simplifies operation and eliminates the
need for special gas installation in the laboratory.
• If SQ analysis is required, switching between preset
Kinetic Energy Discrimination (KED) mode and TQ
modes is possible in a single sample analysis for rapid
and reliable results.
• The Reaction Finder Method Development Assistant
dramatically simplifies method development. No
requirement for advance knowledge of complex
reaction chemistry is necessary—Reaction Finder
does it for you!
91
[AsO]⁺
Q3 set to product
ion mass (m/z 91)
150
40Ar35
Nd⁺⁺,
Cl⁺
150
Sm⁺⁺
Let Reaction Finder select the right
mode for your analysis
SQ mode: Comparable to SQ-ICP-MS instruments,
Q1 transmits all masses
TQ on mass mode: Q1 and Q3 set to the same mass
TQ mass shift mode: Q1 and Q3 set to dierent masses
111
Cd⁺
Q3 set to product
ion mass (m/z 111)
MoO2⁺
reactive gas (O
Q1 set to analyte
mass (m/z 75)
4
Q2 filled with
2
75
150
As⁺,
)
150
Nd⁺⁺,
"Mass Shift"
75
As⁺
into
150
N d ⁺,
Sm⁺⁺, 40Ar35Cl⁺
is converted
75As16
O⁺
150
S m⁺, 91Zr⁺
Q2 filled with
reactive gas (O
Q1 set to analyte
mass (m/z 111)
2
)
111
Cd⁺, 95Mo16O⁺
"On Mass"
95Mo16O⁺
oxide products such
as MoO
95
Mo⁺
forms higher
⁺
2