UV-Vis spectroscopy solutions
for research labs
Leveraging 60 years of spectroscopy experience, Thermo Scientic™
GENESYS™ UV-Vis spectrophotometers oer superior performance, walk-
up convenience and a modern ergonomic design. With a broad range of
accessories, the GENESYS UV-Vis spectrophotometers can meet nearly every
need of academic research, QA/QC and R&D laboratories.
Thermo Scientific™ GENESYS™ 150 UV-Vis Spectrophotometer
Research quality measurements with routine simplicity
• Dual (split) beam optics for accuracy
• Xenon flash lamp flashes only during measurements saving power and lamp life
• High resolution, lab-glove-compatible touchscreen interface tilts to avoid glare
• Peltier thermostatted cell holder, sipper, 8-cell changer and fiber-optic dip probe accessories for advanced experimental needs
• Access favorite methods quickly with Smart Start operation
• Export data via USB, Ethernet, or Wi-Fi; print reports from on-board control via Ethernet or Wi-Fi
For life science labs, the Thermo Scientific™ BioMate™ 160 model includes all the features of the GENESYS 150 instrument plus pre-programmed life
science methods. The GENESYS 150 is also available as a Visible-range instrument (Thermo Scientific
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer
High-throughput ready
Includes
correct for changing absorbance of your sample matrix; 8 cell changer included.
Thermo Scientific™ GENESYS™ 50 UV-Vis Spectrophotometer
Modern functionality for single cell analysis
• Tough fixed-position, high-resolution, lab-glove compatible touchscreen
• Rugged sample compartment; removable, washable liner for easy clean-up
• Support for cuvettes up to 100 mm pathlength and test tubes up to 150 mm tall
Also available as a Visible-range instrument (Thermo Scientific™ GENESYS™ 40 Visible Spectrophotometer).
Description Part Number
GENESYS 40 Visible Spectrophotometer 840-297000*
GENESYS 50 UV-Visible Spectrophotometer 840-298000*
all of the features the GENESYS 150 instrument plus double beam optical design to
and 25 mm diameter
™
GENESYS™ 140 Visible Spectrophotometer).
GENESYS 140 Visible Spectrophotometer 840-308000*
GENESYS 150 UV-Visible Spectrophotometer 840-300000*
GENESYS 180 UV-Visible Spectrophotometer 840-309000*
BioMate 160 UV-Visible Spectrophotometer 840-301000*
*USA country power cable par t numbers listed. For other countries, substitute last three numbers
from 000 to: 100 = China • 200 = India/RSA • 300 = EU • 400 = UK • 500 = Aus/NZ
Also available for your research needs:
Thermo Scientific™ Evolution 201/220 UV-Vis Spectrophotometer
Flexibility and reliability for method development
• Double beam optical design to correct for changing absorbance of the sample matrix
• Precisely known zero-time data and electronic in/out triggering deliver the highest
level of accuracy for rapid-mixing kinetics measurements
• Cell changers and sipper are cable-free, snap-in Thermo Scientific
initialization to speed your analysis
• Selectable bandwidth option and Thermo Scientific
Description Part Number
Evolution 201 UV-Visible Spectrophotometer, PC control 840-210800
Evolution 220 UV-Visible Spectrophotometer, PC control 840-210600
™
Smart Accessories™ with auto-recognition and
™
INSIGHT™ software for 21 CFR Part 11 compliance
Feature GENESYS 50 UV-Vis** GENESYS 150 UV-Vis** GENESYS 180 UV-Vis
Applications
Beam Geometry
Optical System
Spectral Bandwidth
Detector
Wavelength Range
High-definition Color Display
Room-light Resistance
Full Spectrum Scanning, Live
Display, Fixed mode, Quant,
Peak Pick, Kinetics
21 CFR Part 11 Compliance
Printer Options
8-cell Changer
Supports Peltier, Fiber Probe
Connectivity
Performance Verification
Choose the right UV-Visible spectrophotometer for your research applications
Warranty
Evolution 201/220
UV-Vis
For labs with large
For routine single-cell
analysis
Dual Beam (internal reference correction)
|
|
2.0 nm 2.0 nm 2.0 nm
|
Yes Yes Yes Computer or tablet control
No Yes Yes Yes
Yes Yes Yes Yes
No No No Yes
|
No Optional Standard Optional
No Yes Yes Yes
Yes Yes Yes Yes, Pharma capable
|
2-year warranty, 3rd year available when registered
numbers of samples or
specialized accessory
needs
Xenon Flash Lamp, Czerny-Turner Monochromator
Dual Silicon Photodiodes
Snap-on printer and laser printer
USB, Ethernet, Wi-Fi (optional) PC control
For labs with large
numbers of samples,
specialized accessory
needs or assays that
require a reference cell
Double Beam (both sample and reference cuvettes)
}
190 – 1100 nm
For labs that require
sophisticated accessories
or 21 CFR Part 11
compliance
1 nm (Evo 201); userselectable (Evo220)
Print from INSIGHT PC
}
software (optional)
1 year
}
}
}
**GENESYS 40 and 140 Visible spectrophotometers includes Tungsten-Halogen lamp, 4.0 nm spectral bandwidth and a wavelength range of 325 - 1100 nm
Find out more at thermofisher.com/genesys
For Research Use Only. Not for use in diagnostic pr ocedures. © 2 018 Thermo Fisher Scientific Inc. All rights reserved. A ll trademarks
are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise speci fied. FL52306_E 01/18M