Products tested and found to be in compliance with the requirements defined
in the EMC standards defined by 89/336/EEC as well as Low Voltage Directive
(LVD) 73/23/EEC can be identified by the CE label on the rear of the unit. The
testing has demonstrated compliance with the following directives:
LVD, 73/23/EECComplies with UL 3101-1:93
EMC, 89/336/EECEN 55011, Class A Verification
EN 50082-1:1992
IEC 1000-4-2:1995
IEC 1000-4-3:1994
IEC 1000-4-4:1995
For any additional information refer to the Letter of Compliance that shipped
with the unit (Declaration of Conformity).
Retain all cartons and packing material until the unit is operated and found to
be in good condition. If the unit shows external or internal damage, or does
not operate properly, contact the transportation company and file a damage
claim. Under ICC regulations, this is your responsibility.
WarrantyWarranty
Warranty
WarrantyWarranty
NES-care NES-care
NES-care
NES-care NES-care
Warranty ContractWarranty Contract
Warranty Contract
Warranty ContractWarranty Contract
After-sale SupportAfter-sale Support
After-sale Support
After-sale SupportAfter-sale Support
ExtendedExtended
Extended
ExtendedExtended
Units have a warranty against defective parts and workmanship for one full
year from date of shipment. See back page for more details.
• Extend parts and labor coverage for an additional year.
• Worry-free operation.
• Control service costs.
• Eliminate the need to generate repair orders.
• No unexpected repair costs.
Other contract options are available. Please contact NESLAB for more
information.
Thermo NESLAB is committed to customer service both during and after the
sale. If you have questions concerning the operation of your unit, contact our
Sales Department. If your unit fails to operate properly, or if you have
questions concerning spare parts or Service Contracts, contact our Customer Service Department. Before calling, please obtain the following
information from the unit's serial number label:
-BOM number _____________________
-Serial number _____________________
- 2 -
WarningsWarnings
Warnings
WarningsWarnings
Section I SafSection I Saf
Section I Saf
Section I SafSection I Saf
etyety
ety
etyety
Make sure you read and understand all instructions and safety precautions
listed in this manual before installing or operating your unit. If you have any
questions concerning the operation of your unit or the information in this
manual, contact our Sales Department.
Performance of installation, operation, or maintenance proceduresPerformance of installation, operation, or maintenance procedures
Performance of installation, operation, or maintenance procedures
Performance of installation, operation, or maintenance proceduresPerformance of installation, operation, or maintenance procedures
other than those described in this manual may result in a hazardousother than those described in this manual may result in a hazardous
other than those described in this manual may result in a hazardous
other than those described in this manual may result in a hazardousother than those described in this manual may result in a hazardous
situation and may void the manufacturer's warranty.situation and may void the manufacturer's warranty.
situation and may void the manufacturer's warranty.
situation and may void the manufacturer's warranty.situation and may void the manufacturer's warranty.
Observe all warning labels.Observe all warning labels.
Observe all warning labels.
Observe all warning labels.Observe all warning labels.
Never remove warning labels.Never remove warning labels.
Never remove warning labels.
Never remove warning labels.Never remove warning labels.
Never operate damaged or leaking equipment.Never operate damaged or leaking equipment.
Never operate damaged or leaking equipment.
Never operate damaged or leaking equipment.Never operate damaged or leaking equipment.
Never operate the unit without bath fluid in the bath.Never operate the unit without bath fluid in the bath.
Never operate the unit without bath fluid in the bath.
Never operate the unit without bath fluid in the bath.Never operate the unit without bath fluid in the bath.
Never use pure ethylene glycol as a bath fluid. A minimum 80/20Never use pure ethylene glycol as a bath fluid. A minimum 80/20
Never use pure ethylene glycol as a bath fluid. A minimum 80/20
Never use pure ethylene glycol as a bath fluid. A minimum 80/20Never use pure ethylene glycol as a bath fluid. A minimum 80/20
mixture of Ethylene Glycol and tap water is allowed.mixture of Ethylene Glycol and tap water is allowed.
mixture of Ethylene Glycol and tap water is allowed.
mixture of Ethylene Glycol and tap water is allowed.mixture of Ethylene Glycol and tap water is allowed.
For 220 - 240 volt units supplied without a line cord, use a harmonizedFor 220 - 240 volt units supplied without a line cord, use a harmonized
For 220 - 240 volt units supplied without a line cord, use a harmonized
For 220 - 240 volt units supplied without a line cord, use a harmonizedFor 220 - 240 volt units supplied without a line cord, use a harmonized
(HAR) grounded 3-conductor cord, type H05VV-F, with conductors(HAR) grounded 3-conductor cord, type H05VV-F, with conductors
(HAR) grounded 3-conductor cord, type H05VV-F, with conductors
(HAR) grounded 3-conductor cord, type H05VV-F, with conductors(HAR) grounded 3-conductor cord, type H05VV-F, with conductors
listed below. A suitable cord end is required for connecting to thelisted below. A suitable cord end is required for connecting to the
listed below. A suitable cord end is required for connecting to the
listed below. A suitable cord end is required for connecting to thelisted below. A suitable cord end is required for connecting to the
equipment (see unit socket) and must terminate with an IEC approvedequipment (see unit socket) and must terminate with an IEC approved
equipment (see unit socket) and must terminate with an IEC approved
equipment (see unit socket) and must terminate with an IEC approvedequipment (see unit socket) and must terminate with an IEC approved
plug for proper connection to power supply.plug for proper connection to power supply.
plug for proper connection to power supply.
plug for proper connection to power supply.plug for proper connection to power supply.
22
2
NON-BOOST HEATER UNITSNON-BOOST HEATER UNITS
NON-BOOST HEATER UNITS
NON-BOOST HEATER UNITSNON-BOOST HEATER UNITS
BOOST HEATER UNITSBOOST HEATER UNITS
BOOST HEATER UNITS
BOOST HEATER UNITSBOOST HEATER UNITS
Always turn off the unit and disconnect the line cord from the powerAlways turn off the unit and disconnect the line cord from the power
Always turn off the unit and disconnect the line cord from the power
Always turn off the unit and disconnect the line cord from the powerAlways turn off the unit and disconnect the line cord from the power
source before performing any service or maintenance procedures, orsource before performing any service or maintenance procedures, or
source before performing any service or maintenance procedures, or
source before performing any service or maintenance procedures, orsource before performing any service or maintenance procedures, or
before moving the unit.before moving the unit.
before moving the unit.
before moving the unit.before moving the unit.
Always empty the bath before moving the unit.Always empty the bath before moving the unit.
Always empty the bath before moving the unit.
Always empty the bath before moving the unit.Always empty the bath before moving the unit.
Never operate equipment with damaged line cords.Never operate equipment with damaged line cords.
Never operate equipment with damaged line cords.
Never operate equipment with damaged line cords.Never operate equipment with damaged line cords.
Refer service and repairs to a qualified technician.Refer service and repairs to a qualified technician.
Refer service and repairs to a qualified technician.
Refer service and repairs to a qualified technician.Refer service and repairs to a qualified technician.
Nominal 1.0 mmNominal 1.0 mm
Nominal 1.0 mm
Nominal 1.0 mmNominal 1.0 mm
Unit Socket: IEC - 320 C13Unit Socket: IEC - 320 C13
Unit Socket: IEC - 320 C13
Unit Socket: IEC - 320 C13Unit Socket: IEC - 320 C13
Nominal 1.5 mmNominal 1.5 mm
Nominal 1.5 mm
Nominal 1.5 mmNominal 1.5 mm
Unit Socket: IEC - 320 C19Unit Socket: IEC - 320 C19
In addition to the safety warnings listed above, warnings are posted
throughout the manual. These warnings are designated by an exclamation
mark inside an equilateral triangle with text highlighted in bold print. Read
and follow these important instructions. Failure to observe these instructions
can result in permanent damage to the unit, significant property damage,
personal injury or death.
- 3 -
DescriptionDescription
Description
DescriptionDescription
SpecificationsSpecifications
Specifications
SpecificationsSpecifications
Section II General InfSection II General Inf
Section II General Inf
Section II General InfSection II General Inf
ormationormation
ormation
ormationormation
The EX Series Bath Circulators are designed to provide temperature control
for applications requiring a fluid work area or pumping to an external system.
The units consist of a circulation pump, stainless steel bath, a work area
cover, and a temperature controller.
Temperature RangeTemperature Range
Temperature Range
Temperature RangeTemperature Range
Analog controller
Digital controller
Temperature StabilityTemperature Stability
Temperature Stability
Temperature StabilityTemperature Stability
Analog controller
Digital controller
Pumping CapacityPumping Capacity
Pumping Capacity
Pumping CapacityPumping Capacity
HeaterHeater
Heater
HeaterHeater
Watts
50 Hz Models
Bath Work AreaBath Work Area
Bath Work Area
Bath Work AreaBath Work Area
(H x W x D)
Inches
Centimeters
Bath VolumeBath Volume
Bath Volume
Bath VolumeBath Volume
Liters
Case DimensionsCase Dimensions
Case Dimensions
Case DimensionsCase Dimensions
(L x W x D)
Inches
Centimeters
EX-111EX-111
EX-111
EX-111EX-111
11
1
11
EX-211EX-211
EX-211
EX-211EX-211
Ambient +3°C to +100°C
Ambient +3°C to +150°C
22
2
22
±0.1°C
±0.01°C
15 lpm at 0' (0 M)
0 lpm at 16' (4.9 M)
800
1000
4 3/4 x 8 x 6
12.1 x 20.3 x 15.2
9 1/4 x 10 x 6
23.5 x 25.4 x 15.2
12.257.0
17 x 10 5/16 x 15 7/8
43.2 x 26.2 x 40.3
17 x 12 3/8 x 18 3/8
43.2 x 31.4 x 46.7
33
3
Power RequirementsPower Requirements
Power Requirements
Power RequirementsPower Requirements
33
1. Low-end temperature with tap water cooling. The controller may be set to -30°C, however to
2. Stability is a function of the bath fluid temperature. The use of a work area cover and tap
3. Power Board Transformer Fuse–Analog T 0.5A 250V (Qty 1), Digital T 0.8A 250V (Qty 2)
115 V, 60 Hz, 9 Amps
220/240 V, 50 Hz, 5.5 Amps
achieve temperatures below the specified range requires accessory cooling. Contact Thermo
Neslab for more details.
water cooling may optimize bath stability for your work. For some applications, agitation and
stability above ambient temperatures may be may be improved by connecting a small length
of hose between the PUMP INLET and PUMP OUTLET connections on the rear of the unit.
[T=Time Delay]
- 4 -
SpecificationsSpecifications
Specifications
SpecificationsSpecifications
Temperature RangeTemperature Range
Temperature Range
Temperature RangeTemperature Range
Analog controller
Digital controller
Temperature StabilityTemperature Stability
Temperature Stability
Temperature StabilityTemperature Stability
Analog controller
Digital controller
Pumping CapacityPumping Capacity
Pumping Capacity
Pumping CapacityPumping Capacity
HeaterHeater
Heater
HeaterHeater
Watts
50 Hz Models
Bath Work AreaBath Work Area
Bath Work Area
Bath Work AreaBath Work Area
(H x W x D)
Inches
Centimeters
EX-221EX-221
EX-221
EX-221EX-221
11
1
11
EX-411EX-411
EX-411
EX-411EX-411
EX-511 EX-511
EX-511
EX-511 EX-511
Ambient +3°C to +100°C
Ambient +3°C to +150°C
22
2
22
±0.1°C
±0.01°C
15 lpm at 0' (0 M)
0 lpm at 16' (4.9 M)
800/800 boost
1000/800 boost
9 1/4 x 10 x 9
23.5 x 25.4 x 22.9
800
1000
19 1/4 x 10 x 6
48.9 x 25.4 x 15.2
800/800 boost
1000/800 boost
16 1/4 x 10 x 12
41.3 x 25.4 x 30.5
Bath VolumeBath Volume
Bath Volume
Bath VolumeBath Volume
Liters
Case DimensionsCase Dimensions
Case Dimensions
Case DimensionsCase Dimensions
(L x W x D)
Inches
Centimeters
33
3
Power RequirementsPower Requirements
Power Requirements
Power RequirementsPower Requirements
33
20.522.041.5
20 x 12 3/8 x 18 3/8
50.8 x 31.4 x 46.7
115 V, 60 Hz, 16 Amps
220/240 V, 50 Hz, 10 Amps
1. Low-end temperature with tap water cooling. The controller may be set to -30°C, however to
achieve temperatures below the specified range requires accessory cooling. Contact Thermo
Neslab for more details.
2. Stability is a function of the bath fluid temperature. The use of a work area cover and tap
water cooling may optimize bath stability for your work. For some applications, agitation and
stability above ambient temperatures may be may be improved by connecting a small length
of hose between the PUMP INLET and PUMP OUTLET connections on the rear of the unit.
3. Power Board Transformer Fuse–Analog T 0.5A 250V (Qty 1), Digital T 0.8A 250V (Qty 2)
[T=Time Delay]
17 x 12 3/8 x 28 3/8
43.2 x 31.4 x 72.1
115 V, 60 Hz, 9 Amps
220/240 V, 50 Hz, 5.5 Amps
23 x 12 3/8 x 25 3/8
58.4 x 31.4 x 64.5
115 V, 60 Hz, 16 Amps
220/240 V, 50 Hz, 10 Amps
- 5 -
SiteSite
Site
SiteSite
ElectricalElectrical
Electrical
ElectricalElectrical
RequirementsRequirements
Requirements
RequirementsRequirements
Section III InstallationSection III Installation
Section III Installation
Section III InstallationSection III Installation
Never place the unit in a location where excessive heat, moisture, orNever place the unit in a location where excessive heat, moisture, or
Never place the unit in a location where excessive heat, moisture, or
Never place the unit in a location where excessive heat, moisture, orNever place the unit in a location where excessive heat, moisture, or
corrosive materials are present.corrosive materials are present.
corrosive materials are present.
corrosive materials are present.corrosive materials are present.
Lift the unit by grasping it under the case, near the rubber feet.
Locate the unit on a sturdy table or bench top. Ambient temperatures should
be inside the range of +50°F to +80°F (+10°C to +27°C).
Line voltage may be easily accessible inside the pump/control box.Line voltage may be easily accessible inside the pump/control box.
Line voltage may be easily accessible inside the pump/control box.
Line voltage may be easily accessible inside the pump/control box.Line voltage may be easily accessible inside the pump/control box.
Always unplug the unit prior to removing pump/control box cover.Always unplug the unit prior to removing pump/control box cover.
Always unplug the unit prior to removing pump/control box cover.
Always unplug the unit prior to removing pump/control box cover.Always unplug the unit prior to removing pump/control box cover.
Refer to the serial number label on the rear of the unit to identify the specific
electrical requirements of your unit.
En sure the voltage of the power source meets the specified voltage, ±10%.
The unit construction provides extra protection against the risk of electric
shock by grounding appropriate metal parts. The extra protection may not
function unless the power cord is connected to a properly grounded outlet. It
is the user's responsibility to assure a proper ground connection is provided.
For 220 - 240 volt units supplied without a line cord, use a harmonizedFor 220 - 240 volt units supplied without a line cord, use a harmonized
For 220 - 240 volt units supplied without a line cord, use a harmonized
For 220 - 240 volt units supplied without a line cord, use a harmonizedFor 220 - 240 volt units supplied without a line cord, use a harmonized
(HAR) grounded 3-conductor cord, type (HAR) grounded 3-conductor cord, type
(HAR) grounded 3-conductor cord, type
(HAR) grounded 3-conductor cord, type (HAR) grounded 3-conductor cord, type
listed below. A suitable cord end is required for connecting to thelisted below. A suitable cord end is required for connecting to the
listed below. A suitable cord end is required for connecting to the
listed below. A suitable cord end is required for connecting to thelisted below. A suitable cord end is required for connecting to the
equipment (see unit socket) and must terminate with an IEC approvedequipment (see unit socket) and must terminate with an IEC approved
equipment (see unit socket) and must terminate with an IEC approved
equipment (see unit socket) and must terminate with an IEC approvedequipment (see unit socket) and must terminate with an IEC approved
plug for proper connection to power supply.plug for proper connection to power supply.
plug for proper connection to power supply.
plug for proper connection to power supply.plug for proper connection to power supply.
NON-BOOST HEATER UNITSNON-BOOST HEATER UNITS
NON-BOOST HEATER UNITS
NON-BOOST HEATER UNITSNON-BOOST HEATER UNITS
BOOST HEATER UNITSBOOST HEATER UNITS
BOOST HEATER UNITS
BOOST HEATER UNITSBOOST HEATER UNITS
Nominal 1.0 mmNominal 1.0 mm
Nominal 1.0 mm
Nominal 1.0 mmNominal 1.0 mm
Unit Socket: IEC - 320 C13Unit Socket: IEC - 320 C13
Unit Socket: IEC - 320 C13
Unit Socket: IEC - 320 C13Unit Socket: IEC - 320 C13
Nominal 1.5 mmNominal 1.5 mm
Nominal 1.5 mm
Nominal 1.5 mmNominal 1.5 mm
Unit Socket: IEC - 320 C19Unit Socket: IEC - 320 C19
Ensure the unit is off before connecting tubing to the unit.Ensure the unit is off before connecting tubing to the unit.
Ensure the unit is off before connecting tubing to the unit.
Ensure the unit is off before connecting tubing to the unit.Ensure the unit is off before connecting tubing to the unit.
To prevent damage to the plumbing lines, always support theTo prevent damage to the plumbing lines, always support the
To prevent damage to the plumbing lines, always support the
To prevent damage to the plumbing lines, always support theTo prevent damage to the plumbing lines, always support the
¾" fittings while installing/removing the pumping caps and lines.¾" fittings while installing/removing the pumping caps and lines.
¾" fittings while installing/removing the pumping caps and lines.
¾" fittings while installing/removing the pumping caps and lines.¾" fittings while installing/removing the pumping caps and lines.
Hose ConnectionsHose Connections
Hose Connections
Hose ConnectionsHose Connections
The pump connections are located at the rear of the pump box and are
labelled PUMP INLET and PUMP OUTLET. These connections are bent
upward so the recirculating fluid will drain back into the reservoir when the
hoses are disconnected. The connections are capped with stainless steel
serrated plugs.
The pump lines have ¼" MPT for mating with standard plumbing fittings. For
your convenience two stainless steel adapters, ¼" FPT to 3/8" O.D. serrated
fitting, are provided. (To assure proper fit, they should be installed using 1½
turns of Teflon® tape around the threads.)
Flexible tubing, if used, should be of heavy wall or reinforced construction.
Make sure all tubing connections are securely clamped. Avoid running
tubing near radiators, hot water pipes, etc. If substantial lengths of tubing
are necessary, insulation may be required to prevent loss of cooling capacity.
Tubing and insulation are available from Thermo NESLAB. Contact our Sales
Department for more information (see Preface, After-sale Support).
It is important to keep the distance between the unit and the external system
as short as possible, and to use the largest diameter tubing practical. Tubing
should be straight and without bends. If diameter reductions must be made,
make them at the inlet and outlet of the external system, not at the unit.
If substantial lengths of cooling lines are required, they should be pre-filled
with bath fluid before connecting them to the unit. This will ensure that a
adequate amount of fluid will be in the bath once it is in operation.
PumpingPumping
Pumping
PumpingPumping
The pump is designed to deliver a flow of 15 liters/minute (4 gallons per
minute) at 0 feet head. To prevent external circulation, the PUMP INLET and
PUMP OUTLET lines are capped. The caps must be removed when external
circulation is required.
To properly secure the external hose connections to the unit, wrap teflon
tape around the pipe line threads before installation. Once the hose connections are made, the pump must be properly plumbed to an external system.
It is important the bath is not in operation until all plumbing is complete.
If the bath is not used for external circulation, make sure the stainless steel
caps are in place prior to operating the bath.
- 7 -