Discover why laboratories across
the globe rely on Thermo Scientific
products every day.
Successful incubation is dependent upon environmental conditions. As such, you need to
trust that your valuable samples are maintained in a safe and efficient manner.
Heratherm microbiological incubators are designed to provide long-term performance with
optimal conditions – and are backed by a two-year warranty on parts and labor, meaning
confidence for your investment.*
•
Safe view of samples through internal glass door, without impact on temperature
•
Safe conditions with exceptiona temperature uniformity
•
safe
easy
Safe containment with automatic overtemperature alarm
•
Alarm for temperature deviations
•
Easy temperature setting with intuitive user interface
•
Easy to remove shelf system
•
Easy to clean interior with rounded corners
•
Easy to read large display
•
Efficient small footprint to optimize laboratory space
•
efficient
*Subject to Thermo Fisher Scientific Standard Limited Warranty. See www.thermofisher.com or product literature for details.
**Optional stacking kit only required if decon cycle or oven is used below or for stacking different sizes.
Efficient utilization of interior with flexible shelf system
•
Conveniently stackable without the need for tools or stacking kits**
3
Page 4
Innovative technology
for outstanding versatility
FEATURES COMPACT GENERAL PROTOCOL ADVANCED PROTOCOL ADVANCED PROTOCOL
INCUBATOR INCUBATORS INCUBATORS SECURITY INCUBATORS
table top table top large capacity table top table top large capacity
Temperature range 17 - 40 °C ambient +5 °C - 75 °C ambient +5 °C - 105 °C ambient +5 °C - 105 °C
Dry alarm contact for connection of alarm device – – – 4
Interior socket – – 4–
Optional stainless steel exterior – – – 4
Certified decontamination cycle – – – 4
Automatic undertemperature alarm – – – 4
Door alarm – – – 4
Lockable door – – – 4–
Connection for optional sample temperature sensor–––4
Three airflow technologies
Gravity convection
provides gentle airflow, with minimized
drying out of samples. The best choice
1
for applications with open plates or
open containers.
Mechanical convection
provides even higher temperature uniformity and stability to ensure an optimal environment for your
samples. Fan enables fast recovery time after opening the door. A mechanical convection incubator
can even be used for drying applications at high temperature settings – eliminating the need for an
additional oven.
NEW! Dual convection
is a unique technology which allows the operator to
choose the fan speed – from 0% (which equals gravity
convection) up to 100%. Depending on the application,
the speed can be adapted to provide optimal airflow for
your valuable samples.
Bacterial research Bacteria Temperatures between 30 °C and 70 °C
Microbiology Microorganisms, cells Temperatures between 30 °C and 50 °C
Coliform determination Bacteria Temperature around 37 °C
Histology Tissue Temperature around 37 °C
Paraffin embedding Paraffin Temperatures of 37 °C to around 50 °C
Egg incubation Eggs Temperature around 37 °C
Heated storage Media, samples Temperature depends on material and
specific application – between 30 °C and 105 °C
Gene cloning Bacteria, cells Temperature around 37 °C
Pharmaceutical Various Temperatures of 37 °C up to 105 °C
stability testing
Food and beverage Various Temperatures of 37 °C up to 105 °C
testing
BOD/water pollution testing Water Temperature around 20 °C
Yeast growth Yeast Temperatures between 10 °C and 37 °C
Hatching of insects, fish Insects, fish Temperature near or below ambient
General Protocol, Advanced Protocol or Advanced Protocol Security for highest
temperature accuracy, and time control
General Protocol, Advanced Protocol or Advanced Protocol Security for highest
temperature accuracy, and time control
General Protocol for temperatures up to 75 °C, Advanced Protocol or Advanced Protocol
Security for highest temperature accuracy, and time control – up to 105 °C
Advanced Protocol for highest temperature accuracy and time control
Advanced Protocol Security with additional safety features for peace of mind
Compact
General Protocol for temperatures above ambient +5 °C
Advanced Protocol or Advanced Protocol Security for highest temperature accuracy or
Compact for temperatures as low as 17 °C
For lower temperatures check the Thermo Scientific refrigerated models at
www.thermoscientific.com/incubators
Footprint comparison*
Making best use of valuable space
in your lab, Heratherm microbiological
incubators are designed with a very
small footprint ratio compared to the
interior volume. In addition they are
stackable without the need of any
tools or stacking devices.**
manufacturer A
manufacturer B
*based on competitors’ published specs; ** optional stacking kit required only if decon cycle or oven is used below or for stacking different sizes
Maximized space efficiency
5
Page 6
Thermo Scientific Heratherm
Compact Incubator
The most compact unit of the Heratherm microbiological incubator
family has an 18 L capacity, ideal for a personalized workspace.
Order number 50125590 Order number 51028063 51028064 51028065
Model IMC18 Model IGS60 IGS100 IGS180
Convection technology Mechanical convection Convection technology Gravity convection Gravity convection Gravity convection
Temperature range °C 17 °C to 40 °C Temperature range °C ambient +5 °C to 75 °C ambient +5 °C to 75 °C ambient +5 °C to 75 °C
Spatial temperature deviation at 37 °C ± 1.2 °C Spatial temperature deviation at 37 °C ± 0.6 °C ± 0.6 °C ± 0.6 °C
Temperature deviation over time at 37 °C ± 0.2 °C Temperature deviation over time at 37 °C ± 0.2 °C ± 0.2 °C ± 0.2 °C
Footprint m2 / sqft 0.12 / 1.3 Footprint m
Chamber volume L / cuft approx. 18 / 0.65 Chamber volume L / cuft 75 / 2.6 117 / 4.0 194 / 6.85
Dimensions chamber, mm / in (W x H x D) 180 x 310 x 290 / 7.1 x 12.2 x 11.4 Dimensions chamber, mm / in (W x H x D) 354 x 508 x 414 / 13.9 x 20.0 x 16.3 464 x 608 x 414 / 18.3 x 23.9 x 16.3 464 x 708 x 589 / 18.3 x 27.9 x 23.2exterior, mm / in (W x H x D) 260 x 415 x 470 / 10.2 x 16.3 x 18.5 exterior
Number of shelves supplied / max 2 / 3 Number of shelves supplied / max 2 / 13 2 / 16 2 / 19
Max. shelf load kg / lb 2 / 4.4 Max. shelf load kg / lb 25 / 55 25 / 55 25 / 55
Rated voltage / frequency V / Hz 100 - 240 / 50/60 Rated voltage / frequency V / Hz 120 / 60 120 / 60 120 / 60
Rated power / max. current W / A 45 / 0.45 - 0.85 Rated power / max. current W / A 300 / 2.5 540 / 4.5 720 / 6
Weight kg / lb 7.2 / 15.9 Weight kg / lb 40 / 88 51 / 112 65 / 143
Energy consumption at 37 °C W 14 Energy consumption at 37 °C W 21 26 31
NOTE: All figures in tables are typical average values for series devices, based on factory standard following norm Din12880.
Please contact us for certification information or IQ/OQ documents.
Heratherm Compact
microbiological incubator, 18 L
• Minimal footprint for space restricted lab areas
• Temperatures at or below ambient
• High temperature accuracy
• Internal light facilitates sample observation
Page 7
Thermo Scientific Heratherm
General Protocol Incubators
Designed for routine applications in pharmaceutical,
medical, food and research laboratories.
Heratherm General Protocol
microbiological incubators,
60 L, 100 L, 180 L models
intelligent design
for improved results
easy to use interface
Heratherm microbiological
incubators have a smooth
inner chamber with easy to
clean rounded corners
Gravity convection provides gentle airflow and minimal drying out
Model IMH60 IMH100 IMH180
Convection technology Dual convection Dual convection Dual convection
Temperature range °C ambient +5 °C to 105 °C ambient +5 °C to 105 °C ambient +5 °C to 105 °C
Spatial temperature deviation
Temperature deviation over time at 37 °C ± 0.1 °C ± 0.1 °C ± 0.1 °C
Footprint m
Chamber volume L / cuft 66 / 2.3 104 / 3.67 178 / 6.3
Dimensions chamber, mm / in (W x H x D) 354 x 508 x 368 / 13.9 x 20.0 x 14.5 464 x 608 x 368 / 18.3 x 23.9 x 14.5 464 x 708 x 543 / 18.3 x 27.9 x 21.4
exterior
Number of shelves supplied / max 2 / 13 2 / 16 2 / 19
Max. shelf load kg / lb 25 / 55 25 / 55 25 / 55
Rated voltage / frequency V / Hz 120 / 60 120 / 60 120 / 60
Rated power / max. current W / A 600 / 5 840 / 7 1020 / 8.5
Weight kg / lb 45 / 99 56 / 123 70 / 154
Energy consumption at 37 °C
1
at 37 °C ± 0.6 / ± 0.2 °C ± 0.6 / ± 0.3 °C ± 0.6 / ± 0.4 °C
2
/ sqft 0.3 / 3.2 0.36 / 3.9 0.47 / 5.1
2
, mm / in (W x H x D) 530 x 720 x 565 / 20.9 x 28.3 x 22.2 640 x 820 x 565 / 25.2 x 32.3 x 22.2 640 x 920 x 738 / 25.2 x 36.2 x 29.1
1
W 23 / 65 30 / 68 36 / 78
Dual convection for versatility of application: fan speed adjustable from 0 to 100%
• Advanced digital timer for daily or weekly on/off cycles
• Stainless steel interior (AISI 304) is easy to clean and corrosion resistant
• Broad temperatures range from 5 °C above ambient to 105 °C – even suitable
for drying application
• Temperature uniformity as good as ± 0.2 °C
• Temperature stability at ± 0.1 °C
1
Values refer to: fan off / fan full speed
2
Depth of handle / display not included in depth (2.6 in); adjustable feet not included in height (1.4 in) – required distance to rear wall: 3.1 in
NOTE: All figures in tables are typical average values for series devices, based on factory standard following norm Din12880. Please contact us for certification information or IQ/OQ documents.
8
Page 9
Thermo Scientific Heratherm
Advanced Protocol Security Incubators
Incorporates additional safety features
for ultimate sample protection.
Heratherm Advanced Protocol Security
microbiological incubator with unique
dual convection and additional alarm
systems, 100 L unit pictured
Lockable door for restricted access
140 °C
push button decontamination
Building on our established CO2 incubator
decontamination technology, introducing the first
microbiological incubators with an independently
certified 140 °C decontamination routine
3
.
Lockable incubator door for restricted access
•
intelligent design for improved results
superior sample protection
140 °C decontamination
Audible alarm if door is left open
•
Automatic over-and-under temperature alarm
•
At 140 °C contaminating microorganisms are reduced to a
•
minimum, comparable to sterilization, within a six hour cycle
o need for separate autoclaving of interior fittings
N
•
Certified by an accredited microbiological institute
Order number (coated exterior) 51028069 51028070 51028111
Model IMH60-S IMH100-S IMH180-S
Order number (stainless steel exterior) 51028264 51028535 51028327
Model IMH60-S SS IMH100-S SS IMH180-S SS
Convection technology Dual convection Dual convection Dual convection
Temperature range °C ambient +5 °C to 105 °C ambient +5 °C to 105 °C ambient +5 °C to 105 °C
Spatial temperature deviation
Temperature deviation over time at 37 °C ± 0.1 °C ± 0.1 °C ± 0.1 °C
Footprint m
Chamber volume L / cuft 66 / 2.3 104 / 3.67 178 / 6.3
Dimensions chamber, mm / in (W x H x D) 354 x 508 x 368 / 13.9 x 20.0 x 14.5 464 x 608 x 368 / 18.3 x 23.9 x 14.5 464 x 708 x 543 / 18.3 x 27.9 x 21.4
exterior
Number of shelves supplied / max 2 / 13 2 / 16 2 / 19
Max. shelf load kg / lb 25 / 55 25 / 55 25 / 55
Rated voltage / frequency V / Hz 120 / 60 120 / 60 120 / 60
Rated power / max. current W / A 1390 / 11.6 1390 / 11.6 1390 / 11.6
Weight kg / lb 45 / 99 56 / 123 70 / 154
Energy consumption at 37 °C
1
Values refer to: fan off / fan full speed
2
Depth of handle / display not included in depth (2.6 in); adjustable feet not included in height (1.4 in) – required distance to rear wall: 3.1 in
3
Verified by independent testing facility (IBFE 9/2010)
NOTE: All figures in tables are typical average values for series devices, based on factory standard following norm Din12880.
Please contact us for certification information or IQ/OQ documents.
1
at 37 °C ± 0.6 / ± 0.2 °C ± 0.6 / ± 0.3 °C ± 0.6 / ± 0.4 °C
2
/ sqft 0.3 / 3.2 0.36 / 3.9 0.47 / 5.1
2
, mm / in (W x H x D) 530 x 720 x 565 / 20.9 x 28.3 x 22.2 640 x 820 x 565 / 25.2 x 32.3 x 22.2 640 x 920 x 738 / 25.2 x 36.2 x 29.1
Gravity convection technology with unique airflow – designed for minimal drying out of samples
•
Flexible shelf system for optimal use of chamber volume
•
Automatic overtemperature alarm system to protect samples – no need for timely manual setting
•
Inner glass door for undisturbed viewing of samples
•
Inner chambers made from corrosion-resistant stainless steel (AISI 430)
•
Protect delicate samples with stable temperature conditions: uniformity of up to ± 0.5 °C and
temperature stability of 0.4 °K at 37 °C
Heratherm large capacity incubators
are available as 400 L and 750 L units
750 L
Page 11
180°
180° door opening allows convenient
access to the interior for hassle free
cleaning and easy loading of probes
Easy to view, vacuum
fluorescent display with
push-button simplicity
Lockable casters for easy set-up and moving
• Large, easy-to-view, vacuum fluorescent display with simple-to-use touch
maximum
convenience
button operation controlled by an onboard microprocessor
• Doors can be opened over 180° for easy access and use
• Stainless steel inner chamber with rounded edges for easy cleaning
• Lockable casters for easy mobility and stability
• Standard access port can be used for independent data monitoring
SPECIFICATIONS TABLE/ORDER NUMBERS LARGE CAPACITY GENERAL PROTOCOL INCUBATORS
Order number 51029321 51029333
Model IGS400 IGS750
Convection technology gravity convection gravity convection
Temperature range °C ambient +5°C to 75°C ambient +5°C to 75°C
Spatial temperature deviation at 37 °C ± 0.5°C ± 1.3 C
Temperature deviation over time at 37 °C ± 0.4°C ± 0.4 C
Footprint m
Chamber volume L / cuft 405 / 14.3 747 / 26.4
Dimensions chamber mm / in (W x H x D) 544 x 1307 x 569 / 21.4 x 51.5 x 22.4 1004 x 1307 x 569 / 39.5 x 51.5 x 22.4
exterior
Number of shelves supplied / max 2 / 39 2 / 39
Max. shelf load kg / lb 30 / 66 30 / 66
Rated voltage / frequency V / Hz 120 / 60 120 / 60
Rated power / max. current W / A 1080 / 9.0 1500 / 12.5
Weight kg / lb 145 / 320 201 / 443
Energy consumption at 37 °C W 55 80
1
Depth of handle / display not included in depth (2.6 in); casters not included in height (4.3 in) – required distance to rear wall: 4.7 in
NOTE: All figures in tables are typical average values for series devices, based on factory standard following norm Din12880. Please contact us for certification information or IQ/OQ documents.
1
mm / in (W x H x D) 778 x 1545 x 770 / 30.6 x 60.8 x 30.3 1261 x 1545 x 770 / 49.6 x 60.8 x 30.3
2
/ sqft 0.56 / 6.0 0.91 / 9.8
11
Page 12
Thermo Scientific Heratherm
Advanced Protocol Security Incubators
Mechanical convection technology provides exceptional temperature uniformity
and stability to ensure fully reproducible results. An extensive range of
additional features provides even more flexibility, accuracy and dependability.
• Mechanical convection technology ensures optimal temperature distribution with improved level of
temperature uniformity: ± 0.2 to 0.3 °C
• Temperature range from ambient +5 °C to 105 °C for application flexibility: units can even be used
for drying applications
• Unique 140°C decontamination cycle eliminates the need for separate autoclaving or use of toxic
decontaminants
• 2-speed fan for application flexibility:
> Slow speed for incubation applications that require reduced drying out
> High speed for best temperature uniformity and stability
• An additional undertemp alarm provides safety even when the temperature deviates below set point
• Door alarm notifies operator if door is left open
Page 13
Advanced Protocol security units
available in stainless steel exterior
Additional features
Unique certified decontamination cycle.
Access port for independent sensor or
use of shaker / stirrer inside the unit
Two speed fan for matching
the airflow to your application
• Sophisticated timer extends the automation options available to user
enhanced efficiency
> Choose between a simple on/off timer, recurring weekly timer or set incubator
activity based on the 24-hour clock
• Inner chamber made from stainless steel (highly resistant quality AISI 304)
SPECIFICATIONS TABLE/ORDER NUMBERS LARGE CAPACITY ADVANCED PROTOCOL SECURITY INCUBATORS
Order number (coated exterior) 51029323 51029335
Model IMH400-S IMH750-S
Order number (stainless steel exterior) 51029324 51029336
Model IMH400-S SS IMH750-S SS
Convection technology mechanical convection mechanical convection
Temperature range °C ambient +5 °C to 105 °C ambient +5 °C to 105 °C
Spatial temperature deviation at 37 °C ± 0.2 °C ± 0.3 °C
Temperature deviation over time at 37 °C ± 0.2 °C ± 0.2 °C
Footprint m
Volume of workspace L / cuft 381 / 13.5 702 / 24.8
Dimensions chamber mm / in (W x H x D) 544 x 1335 x 524 / 21.4 x 52.6 x 20.6 1004 x 1335 x 524 / 39.5 x 52.6 x 20.6
exterior
Number of shelves supplied / max 2 / 39 2 / 39
Max. shelf load kg / lb 30 / 66 30 / 66
Rated voltage / frequency V / Hz 120 / 60 120 / 60
Rated power / max. current W / A 1380 / 11.5 1560 / 13
Weight kg / lb 144 / 318 205 / 452
Energy consumption at 37 °C W 94 161
1
Depth of handle / display not included in depth (2.6 in); casters not included in height (4.3 in) – required distance to rear wall: 4.7 in
NOTE: All figures in tables are typical average values for series devices, based on factory standard following norm Din12880. Pl
1
mm / in (W x H x D) 778 x 1545 x 770 / 30.6 x 60.8 x 30.3 1261 x 1545 x 770 / 49.6 x 60.8 x 30.3
2
/ sqft 0.56 / 6.0 0.91 / 9.8
ease contact us for certification information or IQ/OQ documents.
13
Page 14
Stainless Steel
Exterior
An optional stainless steel exterior is available
for the Advanced Protocol Security models.
Heratherm Advanced Protocol Security
microbiological incubators with stainless
steel exterior
Maximized performance:
• Robust and corrosion-resistant surface
• Easy-to-clean
• Meets demanding needs in pharmaceutical and clinical
Heratherm incubators offer exceptional
data monitoring systems that provide the
key to reliable results.
Unique optional sample sensor for
Advanced Protocol Security models:
• Measure exact sample temperature, shown on display in
addition to chamber temperature
• Additional peace-of-mind for safety of your precious samples
• Easy connection at rear of unit
RS232 standard on all General Protocol,
Advanced Protocol and Advanced Protocol
Security models/sizes
data monitoring
capabilities
•
All models have an access port
> Ideal for insertion of an independent sample temperature sensor,
for Good Laboratory Practice (GLP) compliance
> Large diameter of 42 / 1.65 (38 / 1.1)* mm/inches fits standard plug
> Covered by stopper to prevent any temperature disturbance
•
All models incorporate a standard RS232 interface
•
Advanced Protocol Security models include a socket for independent sample sensor (option)
when connected, exact sample temperature is shown on display
* General Protocol large capacity units only
15
Page 16
Accessories
SPECIFICATIONS TABLE/ORDER NUMBERS
DESCRIPTION ORDER NUMBER DETAILS
Perforated shelves
Perforated shelf Compact 50125605 Stainless steel perforated shelf for Compact incubator; 7.1 x 11.4 in
Perforated shelf General Protocol 60 L 50127770 Stainless steel perforated shelf for General Protocol 60 L; including 2 shelf supports; 12.95 x 14.80 in
Perforated shelf General Protocol 100 L 50127771 Stainless steel perforated shelf for General Protocol 100 L; including 2 shelf supports; 12.95 x 14.80 in
Perforated shelf General Protocol 180 L 50127772 Stainless steel perforated shelf for General Protocol 180 L; including 2 shelf supports; 12.95 x 12.99 in
Perforated shelf Advanced Protocol / 50127773 Stainless steel perforated shelf for Advanced Protocol / Advanced Protocol Security; 60 L; including 2 shelf supports; 12.95 x 12.99 in
Advanced Protocol Security 60 L
Perforated shelf Advanced Protocol / 50127774 Stainless steel perforated shelf for Advanced Protocol / Advanced Protocol Security; 100 L; including 2 shelf supports; 17.28 x 12.99 in
Advanced Protocol Security 100 L
Perforated shelf Advanced Protocol / 50127777 Stainless steel perforated shelf for Advanced Protocol / Advanced Protocol Security; 180 L; including 2 shelf supports; 17.28 x 19.88 in
Advanced Protocol Security 180 L
Perforated shelf 400 L 50135241 Stainless steel perforated shelf for General Protocol / Advanced Protocol Security 400 L; including 2 shelf supports; 20.79 x 21.06 in
Perforated shelf 750 L 50135242 Stainless steel perforated shelf for General Protocol / Advanced Protocol Security 750 L; including 2 shelf supports; 38.74 x 21.06 in
Additional shelving
Wire mesh shelf 60 L 50127764 Wire mesh shelf for Advanced Protocol / Advanced Protocol Security; 60 L; including 2 shelf supports; 13.31 x 13.22 in
Wire mesh shelf 100 L 50127765 Wire mesh shelf for Advanced Protocol / Advanced Protocol Security; 100 L; including 2 shelf supports; 17.64 x 13.22 in
Wire mesh shelf 180 L 50127766 Wire mesh shelf for Advanced Protocol / Advanced Protocol Security; 180 L; including 2 shelf supports; 17.64 x 20.12 in
Wire mesh shelf 750 L50135244Wire mesh shelf for Advanced Protocol Security; 750 L; including 2 shelf supports; 38.74 x 20.20 in
Petri dish holder (3.54 in) 60 L 50128816 Shelf with holders for petri dishes; ø 3.54 in; stainless steel; for all 60 L incubators; incl. 2 shelf supports; 9 stacks; 3.1 in height
Petri dish holder (3.54 in) 100 L 50128817 Shelf with holders for petri dishes; ø 3.54 in; stainless steel; for all 100 L incubators; incl. 2 shelf supports; 12 stacks; 3.1 in height
Petri dish holder (3.54 in) 180 L 50128818 Shelf with holders for petri dishes; ø 3.54 in; stainless steel; for all 180 L incubators; incl. 2 shelf supports; 16 stacks; 3.1 in height
Petri dish holder (1.97 in) 60 L 50128793 Shelf with holders for petri dishes; ø 1.97 in; stainless steel; for all 60 L incubators; incl.2 shelf supports; 20 stacks; 3.1 in height
Petri dish holder (1.97 in) 100 L 50128794 Shelf with holders for petri dishes; ø 1.97 in; stainless steel; for all 100 L incubators; incl. 2 shelf supports; 24 stacks; 3.1 in height
Petri dish holder (1.97 in) 180 L 50128815 Shelf with holders for petri dishes; ø 1.97 in; stainless steel; for all 180 L incubators; incl. 2 shelf supports; 36 stacks; 3.1 in height
Drip tray 60 L 50128683 Stainless steel drip tray for all 60 L incubators; includes 2 shelf supports; 11.61 x 12.8 x 0.79 in drip space
Drip tray 100 L 50128791 Stainless steel drip tray for all 100 L incubators; includes 2 shelf supports; 11.94 x 12.8 x 0.79 in drip space
Drip tray 180 L 50128792 Stainless steel drip tray for all 180 L incubators; includes 2 shelf supports; 15.94 x 19.69 x 0.79 in drip space
Lowenstein kit 50128265 Lowenstein kit 5.91 in tubes; 2 trays to place on top of perforated shelf (shelf not supplied); 17.13 x 6.1 in; 20 tubes each tray –
usable for 100 L models and larger
Silicone free viton door sealing
Silicone free viton sealing 60 L 50130657 Silicone free viton door sealing for all 60 L incubators
Silicone free viton sealing 100 L 50130658 Silicone free viton door sealing for all 100 L incubators
Silicone free viton sealing 180 L 50130659 Silicone free viton door sealing for all 180 L incubators
Silicone free viton sealing 400 L 50135869 Silicone free viton door sealing for all 400 L incubators
Silicone free viton sealing 750 L 50135870 Silicone free viton door sealing for all 750 L incubators
Stainless steel perforated shelves
Lowenstein trays
Petri dish holderSilicone free viton door sealing
Drip tray
Page 17
Accessories
SPECIFICATIONS TABLE/ORDER NUMBERS
DESCRIPTION ORDER NUMBER DETAILS
Sample sensor
Sample sensor 50127768 Sample sensor for connection to all Advanced Protocol Security incubators: measures exact sample temperature; sample temperature
is shown on display as plugged in; cable length: 86.6 in
Support replace stands
Support stand 60 L 50127741 Support stand with casters for 60 L models; height including casters 7.36 in
Support stand 100 L 50127742 Support stand with casters for 100 L models; height including casters 7.36 in
Support stand 180 L 50127743 Support stand with casters for 180 L models; height including casters 7.36 in
Stacking kits: recommended if decon cycle is performed in lower unit
Stacking kit 60 L 50126665 Stacking kit for 60 L / 2 cu.ft. models
Stacking kit 100 L 50126666 Stacking kit for 100 L / 3.5 cu.ft. models to stack two 100 L models or 60 L on 100 L
Stacking kit 180 L 50126667 Stacking kit for 180 L / 6.4 cu.ft. models to stack two 180 L models or 60 L / 100 L on 180 L
Fresh air particle filter
Fresh air particle filter 50127567 Fresh air particle filter for connection to port; for all Advanced Protocol and Advanced Protocol Security incubators
Stacking kitSupport stand with castersFresh air particle filter
Factory installed options
SPECIFICATIONS TABLE/ORDER NUMBERS
DESCRIPTION ORDER NUMBER DETAILS
Access port left, small 51900996 Additional access port on center of left side of unit; Ø 0.94 in for all incubators.
Access port left, large 51900997 Additional access port on center of left side of unit; Ø 2.28 in for all incubators.
Access port right, small 51900998 Additional access port on center of right side of unit; Ø 0.94 in for all incubators.
Access port right, large 51900999 Additional access port on center of right side of unit; Ø 2.28 in for all incubators.
Access port top, small 51901000 Additional access port on center of top of unit; Ø 0.94 in for all incubators.
Access port top, large 51901001 Additional access port on center of top of unit; Ø 2.28 in for all incubators.
Door hinge left side 51900993 Door hinge on left side – available for General Protocol; Advanced Protocol and Advanced Protocol Security units.
Table top, coated exterior only.
Don’t let a mechanical or electrical failure
ruin your precious samples
Smart: Continuous, real-time monitoring of critical
•
parameters – alerting you remotely when sample
integrity is threatened
Scalable: Flexibility to grow with your expanding
•
laboratory needs
Simple: Easy to install, use and maintain
•
To learn more, visit
www.thermoscientific.com/smart-vue
Solutions vary by RF regions worldwide and are compatible with multiple
brands and types of laboratory equipment. Contact your local sales
representative for more details.
Rear view of the 100 L Advanced Protocol incubator with Smart-Vue