5
POSITIONING
Thermoptek smoke alarms are less prone
to false alarms from cooking fumes, and
are therefore suitable for locations near
kitchens. However like other types of smoke
alarms, thermoptek smoke alarms can be
susceptible to nuisance alarms from steam
and should not be located too close to
bathrooms and showers.
It is recommended that your FireAngel
smoke alarm is NOT to be fitted in the
following locations:
• Bathrooms, shower-rooms, and other very
damp or humid areas, where the moisture
can cause unwanted alarms.
• Kitchens. Kitchen areas should be
protected with self-contained Heat Alarms,
as the combustion particles from cooking
in kitchens will result in unwanted alarms
and permanent contamination of the smoke
alarm’s sensor.
• In areas where excessive dust or dirt could
contaminate the sensing chamber, making
it over sensitive or impairing smoke entry.
• In areas where the ambient temperature
is not controlled and may regularly drift
below 4°C (40°F) or above 38°C (100°F)
e.g. unheated buildings, open attic
spaces.
• Very dirty, dusty or greasy areas.
• In very draughty areas, such as close to
ceiling fans or fresh air vents. Draughts can
blow smoke away from the alarm.
• In insect infested areas. Insects can
clog openings to the sensing chamber,
preventing smoke entry or causing
unwanted alarms.
• Within 30cm (12”) of a uorescent light
fitting which emits electrical ‘noise’ that can
prevent correct alarm operation.
• In wall positions that are more than 30cm
(12”) away from the ceiling (see ‘How to
install your smoke alarm’).
• In ‘dead air’ spaces (see following
diagram).
• Within 30cm (12”) of light ttings or other
ceiling based obstructions.
WARNING: Prolonged exposure to
temperatures outside those stated above
will reduce product life.