Thermoptek FireAngel ST-620 User Manual

User Manual
SMOKE
ALARM
10 YEAR LIFE
ST-620
Please read me – as I could save your life.
AUTOMATIC POWER ENGAGE
SENSOR TECHNOLOGY
APPLICATION
POSITIONING
LIMITATIONS
HOW TO INSTALL YOUR SMOKE ALARM 1 Preparation 2 Install mounting plate 3 Fit your smoke alarm 4 Test your smoke alarm
OPERATION Normal Condition Low Power Pack Condition
ALARM TEST
ALARM SMART SILENCE™
ROUTINE MAINTENANCE
WHAT TO DO IN CASE OF FIRE IN YOUR HOME
REPAIR
TROUBLESHOOTING
DISPOSAL
HOW TO MAKE YOUR HOME SAFER
WARRANTY
RETURNS
PRODUCT RANGE
NOTES
2
2
3
3
5
6
8
10
10
11
13
14
15
16
18
18
20
21
21
22
CONTENTS
Note: This User Manual is also available in large text and other formats. Please call 0800 141 2561 for further information
2
AUTOMATIC POWER
ENGAGE
Your 10 year life smoke alarm is powered by an internal lithium power pack. To avoid unnecessary use of the power pack prior to installation, and to ease disposal when the alarm reaches the end of its life, the alarm is supplied with the power pack in a deactivated state. The power pack is automatically enabled when the alarm is fully locked on to the mounting plate.
WARNING: This automatic power engage system only applies to the
following 10 year smoke alarms:
ST-620
IMPORTANT: Your alarm will not work until it is correctly located and secured
on the mounting plate.
INTRODUCTION
Congratulations! You’ve made a wise investment in protecting your family and home. The ST-620 multi-criteria high performance detector is the ultimate alternative to traditional alarms. Groundbreaking Thermoptek technology combines the very latest in optical sensing with thermal enhancement, providing faster response to both fire types eliminating the need for ionisation sources which can be harmful to the environment. The FireAngel range of products is constantly being improved and expanded. Please visit www.fireangel.co.uk to find out about the latest additions to our range of innovative products.
IMPORTANT: This user manual
contains important information regarding the operation of your FireAngel smoke alarm. Ensure you read this user manual fully before installing and operating the alarm. If you are installing this smoke alarm for use by others, you must leave this manual (or a copy of it) with the end user.
3
SENSOR TECHNOLOGY
Traditionally 3 types of senor technology have been used in domestic self contained fire alarms.
Optical smoke alarms are typically more effective at detecting slow burning fires, which can smoulder for hours before bursting into flames.
Ionisation smoke alarms are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread fire quickly.
Heat alarms are triggered when room temperature reaches a set point (typically 56°C) these alarms are generally used in locations where other alarm types are not suited.
THERMOPTEK SENSOR TECHNOLOGY
Thermoptek technology combines a state of the art optical sensing chamber with thermal enhancement so not only is the alarm effective at detecting slow burning fires, constant monitoring of temperature changes enables the sensitivity of the alarm to be instantly increased thereby quickening the typical response time to fast flaming fires significantly.
APPLICATION
WARNING: Your FireAngel smoke
alarm can be installed into a new build property as additional protection to an existing smoke detection system only. It cannot be used as a substitute for a hard wired system as required in new build properties. In this type of property the building regulations require alarms to be interlinked. You can obtain further information from your local fire service or building control department at your local council offices. These sources generally provide advice on new builds or projects that require planning permission.
Your smoke alarm typically meets the minimum requirements for family living units in existing buildings, as long as at least one unit is installed on each floor/level of your property.
In order to achieve the earliest fire warning, we recommend that a smoke alarm is fitted in all rooms where the temperature is normally between 4°C (40°F) and 38°C (100°F). Check the section on ‘Positioning’ to ensure that the smoke alarm is to be correctly positioned for the particular dwelling into which it is intended to be installed.
WARNING: The alarm positions
shown below are based on typical homes. Construction and layout of individual
4
dwellings will vary, so this should be regarded only as a guide. Check with your local fire station for further guidance.
Multi-family or mixed occupant residence
(Tenancy building, student accommodation)
Your FireAngel smoke alarm can also be used in individual flats and bedsits, providing the same conditions are met as for a single-family residence. However, there must already be a primary fire detection system that meets
LOUNGE
CELLAR
BEDROOMBEDROOM HALL
DINING ROOM
MINIMUM RECOMMENDATIONS
EXISTING HOMES
NOTE: Kitchens should be covered by a self contained heat detector.
RECOMMENDED FOR ADDITIONAL PROTECTION
regulatory requirements for common areas such as lobbies and hallways.
Institutions and Hotels
This includes motels, hospitals, day care facilities, long-term health care facilities, boarding houses and dormitories. Your smoke alarm can be used in individual sleeping/resident rooms, providing the same conditions are met as for a single-family residence. However, there must already be a primary fire detection system that meets regulatory requirements for common areas such as lobbies and hallways. Use of this smoke alarm in common areas may not provide sufficient fire warning to residents or meet regulatory requirements. This smoke alarm is designed to operate as a standalone smoke alarm.
WARNING: This FireAngel smoke
alarm will not communicate with other smoke alarms or fire alarm systems. It is not intended as a substitute for a complete alarm system.
Mobile Homes and Caravans
This smoke alarm is suitable for use in mobile homes and caravans.
Commercial and Industrial Premises
This smoke alarm is not intended for any non-residential, commercial or industrial application, nor for any other purpose than described above.
5
POSITIONING
Thermoptek smoke alarms are less prone to false alarms from cooking fumes, and are therefore suitable for locations near kitchens. However like other types of smoke alarms, thermoptek smoke alarms can be susceptible to nuisance alarms from steam and should not be located too close to bathrooms and showers.
It is recommended that your FireAngel smoke alarm is NOT to be fitted in the following locations:
• Bathrooms, shower-rooms, and other very
damp or humid areas, where the moisture can cause unwanted alarms.
• Kitchens. Kitchen areas should be
protected with self-contained Heat Alarms, as the combustion particles from cooking in kitchens will result in unwanted alarms and permanent contamination of the smoke alarm’s sensor.
• In areas where excessive dust or dirt could
contaminate the sensing chamber, making it over sensitive or impairing smoke entry.
• In areas where the ambient temperature
is not controlled and may regularly drift below 4°C (40°F) or above 38°C (100°F) e.g. unheated buildings, open attic spaces.
• Very dirty, dusty or greasy areas.
• In very draughty areas, such as close to
ceiling fans or fresh air vents. Draughts can blow smoke away from the alarm.
• In insect infested areas. Insects can
clog openings to the sensing chamber, preventing smoke entry or causing unwanted alarms.
• Within 30cm (12”) of a uorescent light
fitting which emits electrical ‘noise’ that can prevent correct alarm operation.
• In wall positions that are more than 30cm
(12”) away from the ceiling (see ‘How to
install your smoke alarm’).
• In ‘dead air’ spaces (see following
diagram).
• Within 30cm (12”) of light ttings or other
ceiling based obstructions.
WARNING: Prolonged exposure to
temperatures outside those stated above will reduce product life.
6
1 METRE
(3 FEET)
DEAD
AIR SPACES
100MM
(4 INCHES)
100MM
(4 INCHES)
BEST LOCATION
(IN CENTRE OF CEILING)
DEAD
AIR SPACES
WHAT ARE THE
LIMITATIONS OF MY
SMOKE ALARM?
Your FireAngel smoke alarm is designed to alert you by sounding an alarm when it senses smoke, i.e. it can only sense smoke and alert you if smoke reaches it! If a fire develops in an area remote from the location of the smoke alarm, such as another room or another level, smoke may not reach the smoke alarm in sufficient time or quantity to sense and alert you to the danger.
We recommend that as a minimum you install Thermoptek smoke alarms on every floor of your property. For comprehensive coverage a smoke alarm should also be fitted in every room.
This smoke alarm cannot be used to provide primary fire detection in common areas used by different residents such as blocks of flats and hotels. The FireAngel smoke alarm may not alarm before a fire causes damage, injury or death, as the smoke may not reach the smoke alarm in time. Examples include smoking in bed and violent gas explosions. This smoke alarm may not respond in a reasonable time if it is not installed in the best position, or if furniture or other obstacles are located between the smoke alarm and the fire.
7
WARNING: Your smoke alarm will not operate without sufficient power.
As the alarm’s power pack reaches the end of its life a low power warning chirp will be emitted every 40 seconds. When this occurs you must replace the unit within 7 days.
IMPORTANT: Smoke alarms are
designed to alert you with an audible alarm at a level specified by the European Standard EN 14604:2005. Closed doors, walls and high ambient noise levels will reduce this level. Temporary or permanently impaired hearing may result in the alarm not being heard. Stereos, traffic and other loud sources may also prevent the alarm being heard. Heavy sleepers and residents under the influence of alcohol or drugs may also not hear or respond to the alarm. Test and check that you can hear the alarm in all circumstances. If in doubt install additional smoke alarms as required.
WARNING: The Smoke alarm is not
suitable for alerting hearing impaired residents. We recommend that specially designed warning systems be installed that will alert hearing impaired residents.
WARNING: The smoke alarm
accompanying this manual employs the latest technology and is independently tested as being compliant with all the relevant European Standards. However, as with any electronic product it may fail and may not
sense all types of fire within sufficient time to alert you of the danger and provide adequate time for your escape. In order to maximise your level of safety always test your smoke alarm frequently to ensure it is in full working order. Your FireAngel smoke alarm is only suitable for use in domestic/ residential applications as covered in this manual. It is not suitable for commercial or industrial applications. It is designed to sense smoke and alert you. It will not sense carbon monoxide, flames, or gas. It will not prevent or extinguish fires.
This FireAngel smoke alarm has a limited life of 10 years and should not be considered as a substitute for life or property insurance. Like all electronic equipment, it can wear out or fail. It should be tested weekly and replaced immediately in the event of failure, and replaced every 10 years regardless.