Thermo Products HA1042 User Manual

Why Humidify?
• Proper humidity reduces static electricity, dried cracked furniture and wood trim, and wilting house plants.
• Your family will feel more comfortable as dry skin, throats and noses are soothed.
Model HA1042 Power Humidifi er
Top quality and high capacity for maximum comfort. Easy to install with any Thermo Pride warm air furnace.
Offers Exceptional Features
Attractive Styling - Modern design utilizing non-corrosive, high
temperature materials makes the humidifier an attractive and dependable component in any warm air heating system.
Proper Humidification - Scientifically designed evaporator pad results in high evaporative output and minimum hard water scale accumulation.
Easy to Service - Thumb screws allow easy access to the distribu­tion trough, drain pan and evaporative pad making cleaning and servicing quick and easy. High capacity drain tube helps prevent clogging.
No Moving Parts - The 1042 drain-type humidifier has no motor, fan or pump to wear out or lime up.
• Properly humidified air feels warmer allowing you to turn your thermostat down a few degrees and reduce energy costs while still keeping your home comfortable.
General Operating Principle
• Evaporation takes place as the heated air from the warm air furnace passes through the moisture laden evaporator pad.
• Water is metered through a solenoid valve then distributed over the pad by a trough at the top of the humidifier.
• Water not evaporated drains from the bottom of the humidifier carrying off troublesome minerals.
• Humidified air is then returned to the heating system to enter the living area.
Clean Operating - The 1042 is 100% evaporative. There is no mineral dust to disturb the household.
Manual Air Shuttle - Closes bypass during summer cooling sea- son. The air shuttle may be used to control humidifier output, however, a humidistat is recommended.
Dependable Solenoid Valve - Has a monel wire mesh filter to protect the precision-machined Teflon flow-control orifice.
Reversible Installation - Right or left-hand take-off may be installed on up-flow, counter-flow or horizontal-flow furnaces.
Application:
F
orced warm-air furnaces
Unit Size
:
½" high x 9" deep
Plenum Opening
:
¼
½" high
Bypass Duct
:
6" diameter (collar supplied)
Water Supply
:
Use
¼
Electrical
:
Model HA1042 Drain Type with Humidistat
- 24 V. 60 Hz.
Drain Connections
:
dia. (15' vinyl hose supplied)
Controls
:
Manual air shutter Humidistat
with HA1042
Specifications
HUMIDITY REQUIREMENTS IN GALLONS PER
DAY BASED ON HOUSE SIZE AND TYPE OF
CONSTRUCTION (FROM ARI GUIDELINE F)
Type of Construction
Tight
Average
Loose
*Based on 8 ft. ceiling height.
500 1000 1500 2000 2500 3000
2.1
3.3
4.6
Size of House (sq. ft.)*
4.2
6.5
9.2
6.4
9.8
13.8
8.5
13.1
18.4
10.6
16.3
23.0
12.7
19.6
27.6
Tight House
With insulated walls and ceilings, vapor barriers, weather stripping on doors and windows, and snug doors, windows and fireplace damper (½ air change per hour)
Average House
Insulated walls and ceilings with vapor barriers, but loose storm doors, windows and fireplace damper (1 air change per hour)
Loose House
Without insulation, storm doors, storm windows, weather stripping or vapor barriers (2 air changes per hour)
Evaporative Capacity Output
Temp°F
GPD
*Industry Standard rating conditions. 140° hot water supplied to
the humidifier in heat pump applications will increase capacity by
4.3 gallons per day.
80° 100° 120° 140°* 1 60°
8.0 12.2 16.4 19.2 23.2
Illustrations and photographs in this brochure are only representative. Due to ongoing engineering upgrades, some variations may occur.
Form No. PL81410061006-2/06-3Ms
Printed in the U.S.A.
© 2006 Thermo Products, LLC - North Judson, IN
Phone: 574-896-2133
www.thermopride.com
Loading...