Thermo Products CHX3-75N, CDX3-125N, CHX3-100N, CHX3-125N, CDX3-100N User Manual

...
ECM OPERATION MANUAL
FOR USE WITH MODELS:
: IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.
LEAVE THE BUILDING IMMEDIATELY.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE. FOLLOW THE GAS
SUPPLIER’S INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUPPLIER; CALL THE FIRE DEPARTMENT. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR
THE GAS SUPPLIER. (REFERRED TO IN THESE INSTRUCTIONS AS A QUALIFIED HEATING CONTRACTOR).
PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE HOMEOWNER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL.
THERMO PRODUCTS, LLC.
BOX 217 NORTH JUDSON, IN 46366 PHONE: (574) 896-2133
MADE IN USA
MG-1037
ECN 5262-MA 120326
All installations and services must be performed by qualified service personnel.
INDEX
SECTION BEGINNING PAGE
I. FURNACE SPECIFICTIONS (SHIPPED SETTINGS) 1
II. BLOWER INFORMATION 3 A. WIRING 3 B. CFM TABLES 5
III. ECM TROUBLESHOOTING 9 A. GENERAL GUIDELINES TO TROUBLESHOOTING GE ECM 9 B. TROUBLESHOOTING CHARTS 12
i
All installations and services must be performed by qualified service personnel.
MODEL NO.
CHX3-75
CHX3-100
CHX3-125
HEAT INPUT RATE IN BTU/ HR (High fire/ Low fire)
75,000 / 52,000
100,000 / 70,000
125,000 / 87,500
HEATING CAPACITY IN BTU/HR (High fire/ Low fire)
70,875 / 49,612
94,500 / 66,150
117,500 / 82,250
HEIGHT OF CASING
44-1/4”
44-1/4”
44-1/4”
WIDTH OF CASING
17”
21”
24”
DEPTH OF CASING
27-1/2”
27-1/2”
27-1/2”
WARM AIR OUTLET
15 x 18
19 x 18
22 x 18
RETURN AIR INLET
25 x 16
25 x 16
25 x 16
DIA. OF FLUE
2”
3”
3”
DIA. OF COMBUSTION AIR INTAKE
FLOWRATE from .2” & .5” w.c. EXTERNAL STATIC PRESSURE
@COOLING TAP A (CFM)
1000
1200
1400
@COOLING TAP B (CFM)
800
1000
1200
@COOLING TAP C (CFM)
1200
1400
1600
@COOLING TAP D (CFM)
1400
1600
2000
HEATING
HEATING
HEATING
@HEATING TAP A (CFM @High fire/Low fire)
931 / 760
1243 / 1015
1556 / 1270
TEMPERATURE RISE (° F)
70 / 60
70 / 60
70 / 60
BLOWER MOTOR HP
.5
.75
1
POWER CHOKES
-
2.65 Mh
2.1 Mh
LARGEST RECOMMENDED AIR CONDITIONER
SIZE OF FILTERS
24-3/4” x 15-3/4”
24-3/4” x 15-3/4”
24-3/4” x 19-3/4”
I. FURNACE SPECIFICATIONS (SHIPPED SETTINGS)
CHX3 SERIES
2” 3” 3”
COOLING COOLING COOLING
NOTES:
1. Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps, for all models).
4. All specifications are subject to change without notice.
3.5 Ton 4 Ton 5 Ton
1
All installations and services must be performed by qualified service personnel.
MODEL NO.
CDX3-75
CDX3-100
CDX3-125
HEATING INPUT RATE IN BTU / HR (High fire / Low fire)
75,000 / 56,250
100,000 / 75,000
125,000 / 93,750
HEATING CAPACITY IN BTU/HR (High fire / Low fire)
69,750 / 52,312
93,000 / 69,750
116,250 / 87,187
HEIGHT OF CASING
46-1/4”
46-1/4”
46-1/4”
WIDTH OF CASING
17”
21”
24”
DEPTH OF CASING
27-1/2”
27-1/2”
27-1/2”
WARM AIR OUTLET
15 x 18
19 x 18
22 x 18
RETURN AIR INLET
15 x 22
19 x 22
22 x 22
DIA. OF FLUE
2”
3”
3”
DIA. OF COMBUSTION AIR INTAKE
FLOWRATE from .2” & .5” w.c. EXTERNAL STATIC PRESSURE
@COOLING TAP A (CFM)
1000
1200
1400
@COOLING TAP B (CFM)
800
1000
1200
@COOLING TAP C (CFM)
1200
1400
1600
@COOLING TAP D (CFM)
1400
1600
2000
HEATING
HEATING
HEATING
@HEATING TAP C (CFM @ High fire / Low fire)
1012 / 826
1340 / 1094
1673 / 1366
TEMPERATURE RISE (° F)
65 / 60
65 / 60
65 / 60
BLOWER MOTOR HP
.5
.75
1
POWER CHOKES
-
2.65Mh
2.1Mh
LARGEST RECOMMENDED AIR CONDITIONER
SIZE OF FILTERS
21-3/4” x 14”(2)
21-3/4” x 14”(2)
21-3/4” x 14”(2)
CDX3 SERIES
2” 3” 3”
COOLING COOLING COOLING
NOTES:
1. Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps. for all models).
4. All specifications are subject to change without notice.
3.5 Ton 4 Ton 5 Ton
2
All installations and services must be performed by qualified service personnel.
II. BLOWER INFORMATION
A. WIRING
Figure 1: BLOWER WIRING
: TURN OFF THE ELECTRICAL POWER to the furnace before atte mpting to disconnect blowe r wiring.
3