Thermolev Master boiler series Instruction And Operation Manual

Instruction and operation manual
Master boiler series Steel hot water boiler
THERM LEV
Hydraulic connection of
Masteriler
AYTOMATIC AIR VENT
BOILER EXIT
FÉLLING VALVE
ÌÂ 25: 1´´ ÌÂ 40-50: 1 & 1/4´´
½ ´´
WATER FOR
USE-ENTRANCE
WATER FOR
USE-EXIT
BOILER
ENTRANCE
½ ´´
½ ´´
Technical manual and user manual of hot watre boiler Master Boiler
( Heating and hot water )
Technical МпнЬдб Type Characteristics МЭфсзузт MB.25 MB.40 MB.50
Nominal output Kcal/h 25,500 40,400 50,200
Kw 30.1 47 58.1
Hot water use Kcal/h 25,500 40,400 50,200
Kw 30.1 47 58.1
Production
Hot water L/H 700 750 800 (ÄÈ : 40°C)
Pressure operation Bar 3 3 3 Voltage operation Volt / Hz 220 / 50
Engine power Burner Watt 90
Room thermostat SIEMENS RAA 30.26 Three speed
Circulator Watt 52-77-110
Fuel type Heating oil Heigth. (A) MM 930 954 954
Length. (B) MM 420 500 500
Depth. (Ã) MM 620 715 715
Chimney MM 102 102 102
Weigth (êåíü) Kgr 120 135 160
* Technical characteristics can change without warning.
Technical characteristics and External dimensions
A
B
Ã
MANUAL MASTER BOILER 03062005 PUBLISH: 1 DATE: 03062005
THERMOLEV company thanks you for your trust in our products. This manual is referred to the technical characteristics of the boiler and provides information on installing and using the boiler. Please read very carefully the warranty booklet and follow all the conditions. After installation, certified technician should sign the quarantee and the correct coupon must be returned in our company.
Master Boiler is an individual boiler for heating and for the production of hot water. Master boiler includes:
- burner
- circulator
- electronic control panel
- thermostat
Notice: Furthermore a silencer chimney can be fitted where it is not possible the existence of an internal chimney.
ISO 9001 - CE** - ISCIR
Page 1 / 5
Operating instructions and electrological connection of control panel Master Boiler
BUTTON 01
BUTTON 04
BUTTON 03
BUTTON 02
LAMP 02
LAMP 01
LAMP 03
LAMP 04
DISPLAY
LAMP 05
BUTTON 01: Increases the indication we wish to regulate.
BUTTON 02: Decreases the indication we wish to regulate.
BUTTON 03: Choose the parameter to regulate it.
PARAMETERS: t 1 : Temperature where the burner stops. d 1 : Low hysteresis of the burner temperature t1. t 2 : Temperature where the circulator starts The operation of heating d 2 : Low hysteresis of the circulator temperature t2 t 3 : temperature where the circulator starts the
Operation of hot water and heating simultaneously
d 3 : Low hysteresis of the circulator temperature t3 S t : Application
BUTTON 04: Switch ON / OFF of the boiler
DISPLAY shows : - the temperature of the boiler when it is standing
- Parameters in the programming
- any damages of the boiler
LAMP 01: lights when the boiler operates LAMP 02: lights when the circulator operates LAMP 03: lights when the circuit protection is activated
LAMP 04: lights when the burner block LAMP 05: lights when the boiler is activated
Programming: Press for 2’’ continiously SET to enter the programming. With up and down arrows
adjust the parameters. To go to the next parameter press SET. When you get to sign S t has finished programming. After this procedure, temperature appears again on the display.
oo
Recommended parameter values : t 1 : 72 C d 1 : 2 C
oo
t 2 : 45 C d 2 : 2 C
oo
t 3 : 64 C d 3 : 2 C
Page 2 / 5
Notice: All the control panels are preset from the factory
ISO 9001 - CE** - ISCIR
MANUAL MASTER BOILER 03062005 PUBLISH: 1 DATE: 03062005
o
Warm protection: If for some reason overcome 92 C circulator is activated and lowers
o
the temperature of the boiler 88 C.
Protection Circuit:
Page 3 / 5
Burners off:
- If short-circuit fault appears in the sensor.
- If sensor is being cut.
- If sensor for any reason stops working. Temperature variation [sensor is removed from its position).
o
Frost protection: If the boiler temperature drops to +2 C the burner is automatically
o
activated and raises the temperature of the boiler to +8 C.
Circulator protection: Automatic activation of the circulator at time periods in order to avoid obstacles
ÔÊÁ
ÔÊÕ
BR
ÊÁ
ÊY
LINE
LINE
GRD
N
HEATING COMMAND [01]
HOT WATER COMMAND [02]
PHASE OF ROOM THERMOSTAT [03]
WHEN BURNER STOPS [05]
BURNER PHASE [06]
GROUNDING [10]
NEUTRAL ROOM THERMOSTAT [04]
CIRCULATOR PHASE [07]
NEUTRAL BURNER-CIRCULATOR [08]
GROUNDING BURNER-CIRCULATOR [09]
NEUTRAL [11]
ÖÁÓÇ [12]
Master Boiler Control panel link
Feeding voltage: AC 220V - 50Hz
Internal safety of the control panel: F 5A / 220V
ISO 9001 - CE** - ISCIR
MANUAL MASTER BOILER 03062005 PUBLISH: 1 DATE 03062005
- Before connecting the thermostat, you should remove the bridge [1],[2]&[3] of the terminal block panel MASTER
BOILER
Instructions:
Page 4 / 5
Room thermostat connection drawing [ SIEMENS RAA 30.26 ]
[ N ]
[ L ]
[ Y 2 ]
[ L 4 ]
HEATING COMMAND [01]
HOT WATER COMMAND [02]
PHASE
ROOM THERMOSTAT [03]
NEUTRAL
ROOM THERMOSTAT [04]
[ Y 1 ]
[ L 5 ]
[ L 50 ]
- You should make the bridge in the thermostat terminal
block [ÕÉ]-[L4] & [L]-[L5], As shown in the diagram
- Can connect more than one room thermostat, in parallel
Boiler operation of the room thermostat
-With the electronic table and the room thermostat can operate in three different independent functions:
1. Boiler for heating.
2. Boiler for hot water production.
3. For heating and hot water simultaneously.
Operation of the room thermostat
- The top switch activate the operation of hot water production.
-The bottom switch activate the operation of heating. (With rotary switch, select the room temperature
you wish for).
- Activating both switches we have heating and hot water simultaneously.
Faults indication and solutions
- [Å 1] Sensor problem: short- circuit sensor cut sensor Unable temperature sensor to read [ Possible exit of the sensor from its position] After you identify and solve the problem activate again the boiler
- [when the burner stops]: Gearing of the burner. After we identify and solve the problem, we activate the burner from the red switch which is located on the burner.
Notice: For any problem of the boiler you must contact your certified technician. Do not interfere other people.
ISO 9001 - CE** - ISCIR
MANUAL MASTER BOILER 03062005 PUBLISH: 1 DATE: 03062005
Installation instructors
Page 5 / 5
For the installation of Master boiler the following hardware need to be connected:
1. Expansion tank (24lt) in the heating circuit or bigger than that if it is required by the installation.
2. Safety valve 1/2" 3BAR.
3. Automatic air vent of 2 pieces or more depending on the installation.
4. Filling valve ½” with manometer.
5. Magnesium anode for protection against salt.
6. Blackflow prevender in hot water circuit.
7. Expansion tank (8lt) in hot sanitary water circuit.
8. Pressure reducer in hot sanitary water circuit since we have increased pressure in our network.
Master iler connection
1. The hydraylic connection of the boiler is based on a project and you can find it on this booklet as well as at back side of the boiler.
2. You should avoid connecting the boiler tuborama with the hot water circuit.
3. The electrical cinnection is based on the diagram of the manual.
Boiler settings
1. The pressure of the heating circuit should be regulated by 1-1,5 BAR.
2. For proper and economical operation the setting of the burner should be done by a licensed technician.
3. The temperature at which the burner stops is preset.
4. The temperature at which the circulator stops is preset.
Boiler maintenance
1. It is necessary the annual cleaning of the boiler as well as cleaning and adjusting the burner by a licensed burner technician.
2. It is also necessary a periodic cleaning of the heat exchanger (coil) to prevent icing salts. Otherwise, alternator will be blocked. The cleaning is done by special liquids that you can find in the market. Time of regular cleaning depends on the hardness of the water and the frequency of use of the boiler.
Room thermostat installation
1. Ôhermostat should be placed in the room that concerns us more the changes in temperature.
2. Thermostat should not be placed near a radiator, in front of a wall that just behind a radiator is
located or in a wall that tubes exists.
3. Also not to be placed near a window or a balcony door.
ISO 9001 - CE** - ISCIR
MANUAL MASTER BOILER 03062005 PUBLISH: 1 DATE: 03062005
site:www.thermolev.com e-mail: thermolev@thermolev.com
tel: 0030 2310 780761-2 Fax: 0030 2310 780814 Thessaloniki-Greece