Thermogroupuk 5259 Installation Manual

ThermoSTAT installation guide
code 5259 1
Technical Information
Voltage: See products P ower Consumption: 2W Setting range: 5...90°C (upper limitation from 35°C - 90°C adjustable) Limitation Range: 5...60
°C (factory setting 35°C)
Switching Differential: 0.5
- 10°C adjustable, factory setting ± 1°C
Ambient Temperature: -5
°C ~ 50°C Protective Housing: IP20 Housing Material: Anti-flammable PC
Simple Set-up
Simple set up Press the po wer switch to turn the unit on Press and hold the clock symbol for 7 seconds a) Using the keys adjust the day (1-7 is mon to sun), press
b) Using the keys adjust the hour, press c) Using the keys adjust the minutes, press
Press the to set Press the key to change between manual , and programme mode In manual mode use the and keys to adjust the desired temperature
Function and Displaty Explanation
Sleep, period 6
Return (pm), period 5
Return (am), period 3
Leave (pm), period 4
Leave (am), period 2
Wake up, period 1
Menu key
Periods programming control mode
Manual control mode
Power key
Heating on
Press and hold the key for 7 seconds, This will adjust da ys 1 to 5 only, Period 1 ON time adjust using the and keys, press ,
Period 1 ON temp adjust using the and keys, press , Period 2 OFF time adjust using the and keys, press , Period 2 OFF temp adjust using the and keys, press , Period 3 ON time adjust using the and keys, press , Period 3 ON temp adjust using the and keys, press , Period 4 OFF time adjust using the and keys, press , Period 4 OFF temp adjust using the and keys, press , Period 5 ON time adjust using the and keys, press , Period 5 ON temp adjust using the and keys, press , Period 6 OFF time adjust using the and keys, press , Period 6 OFF temp adjust using the and keys, press , Days 6 & 7 ON time adjust using the and keys, press , Days 6 & 7 OFF time adjust using the and keys, press ,
Advanced Set-up
Press the  to switch the unit off then Press and hold the  and  buttons together.
1ADJ - Measured temperature display and adjustment
Press the key or key to adjust current measured temperature value, adjustable range: ±9.9°C. Then press the menu key to enter into next advanced setting.
2SEN sensor selection Press the key or key to select sensor working mode IN is internal sensor OUT is external sensor, ALL is both sensors, external sensor is limit sensor. Then press the menu key to enter into next advanced setting.
3LIT adjust limitation temperature valve Press the key or key to adjust limitation temperature value limitation range 5-60°C. Then press the menu key to enter into next advanced setting.
4DIF switching differential (band) setting
Press the key or key to adjust switching differential setting range 0.5-10°C. Then press the menu key to enter into next advanced setting.
5LTP anti-freezing function on/off
Under switch off mode press the key or key to change anti-freezing function status. Then press the menu key to enter into next advanced setting.
Press the  to switch the unit off then Press and hold the  and  butt ons together.
6PRG holiday selection and close weekly programming Press the key or key to selection holiday status 2 days, 1 day, 0 days and closing mode. Then press the menu key to enter into next advanced setting.
7RLE potential-free output and main output
Synchronous/asynchronous direction press the key or key to change current output status 00 is synchronous, 01 is asynchronous. Then press the menu key to enter into next advanced setting.
8DLY potential free time-lapse output time Press the key or key to change the output time range from 0 to 5 minutes. Then press the menu key to enter into next advanced setting.
9HIT maximum temperature setting value Press the key or key to adjust maximum temperature setting from 35 to 90. Then press the menu key to enter into next advanced setting.
AFAC reset to factory setting Press the key for 5 seconds until - - - displayed to restore factory setting. Then press the menu key to enter into the 1st advanced setting item.
Press the switch off key to exit and save the advanced settings.
Press the to switch the unit off then Press and hold the and buttons together.
ITEM
DEFAULT TEMP.
ADJUST
DEFAULT TIME
PERIOD SYMBOL
PERIOD
ADJUST
1
6
5
4
3
2
1
2
08:00
22:00
17:00
12:30
11:30
08:00
06:00
23:00
22°C
15
°C
22
°C
15
°C
15
°C
15
°C
20
°C
15
°C
adjust period time
adjust set temperature
working day holiday
code 5259
Thermogroupuk Bridge House, Hop Pocket Lane, Paddock Wood, Kent. TN12 6DQ
Telephone 08700 41 21 41 Fax 08700 41 21 40 www.thermogroupuk.com sales@thermogroupuk.com
2
3
4
2
1
for more information on our range of underfloor heating systems visit our website at www.thermogroupuk.com
ThermoSTAT installation guide
heating on
minus key
time/temp. display
day number
measured temp.
manual mode
programming mode
plus key
period from 1 to 6
menu key
clock
temp. sensor
on/off switch
1
Function and Display Explanation
Dimensions (mm)
Mounting Guides
disassemble external frame with screw driver disassemble iron plate with screw driver
fix iro plate with crew driver wire cables according to wiring diagram, install
thermostat, fix iron plate with screw driver and cover external frame
System Wiring Diagram
BYC-E91 1 2 3 4 5 6 7
sensor
L1
N1
16A