thermital TSOL CN 150/1 S BLU 30, TSOL CN 200/1 S BLU 30, TSOL CN 300/3 S BLU 30, TSOL CN 220/2 S BLU 30, TSOL CN 300/2 S BLU 30 Installer, Technical Assistance Centre And User Manual

TSOL CN S BLU 30° system
INSTALLER, TECHNICAL ASSISTANCE
CENTRE AND USER MANUAL
2
Dear Customer, Thank you for choosing a T Natural circulation system. You have purchased a modern, quality product that is designed to give dependable and safe service and to provide comfort in the home for many years to come. Arrange for your Natural circulation system to be serviced regularly by an authorised T Technical Assistance Centre. Their personnel are specially trained to keep your product efficient and cheap to run. Your
T Technical Assistance Centre will also
stock any original spare parts that might be required. This instruction manual contains important instructions and precautions that must be observed to ensure the trouble-free installation and efficient functioning of your
T solar water heating system.
Please accept our renewed thanks for your purchase.
CONFORMITY
The solar collectors used in T natural circulation systems conform to EN standard 12975.
T storage cylinders conform to DIN 4753-3 and UNI EN 12897 standards.
RANGE
MODEL CODE
TSOL CN 150/1 S BLU 30° 20101335 TSOL CN 200/1 S BLU 30° 20101338 TSOL CN 220/2 S BLU 30° 20101339 TSOL CN 300/2 S BLU 30° 20101340 TSOL CN 300/3 S BLU 30° 20101341
ACCESSORIES
For a complete list of accessories and details of their compatibility, refer to the Catalogue.
This manual, Code 20100661 - Rev. 2 (04/17) comprises 32 pages.
3
ENGLISH
CONTENTS
The following symbols are used in this manual:
b
CAUTION! =
Identifies actions that require caution and
adequate preparation.
a
STOP! =
Identifies actions that you MUST NOT do.
This manual, Code
- Rev. comprises pages.
ENGLISH
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . 4
Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Description of the system. . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Overall dimensions and weights . . . . . . . . . . . . . . . . . . . . . 7
Water circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTALLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Unpacking the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Handling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Preparing for installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
System water connections . . . . . . . . . . . . . . . . . . . . . . . . . 25
Preparing for initial startup . . . . . . . . . . . . . . . . . . . . . . . . . 26
TECHNICAL ASSISTANCE CENTRE . . . . . . . . . . . 28
Initial startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
END USER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Putting into service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4
ENGLISH
GENERAL
GENERAL SAFETY INFORMATION
b
Check that the product is complete, undamaged and as ordered as soon as you receive it. Report any discrepancies or damage to the T dealer who sold it.
b
This product must be installed by a legally qualified heating engineer. On completion of the installation, the installer must issue the owner with a declaration of conformity confirming that the installation has been completed to the highest standards in compliance with the instructions provided by T in this instruction manual, and that it conforms to all applicable laws and standards.
b
This product must only be used for the purpose for which it is designed and made, as specified by T.
T declines all responsibility, contractual
or other, for damage to property or injury to persons or animals caused by improper installation, adjustment, maintenance or use.
b
Make sure that the roof is strong enough to support the weight of the solar water heating system under operating conditions. Also make sure that the section of roof chosen for the installation enjoys a high level of insolation, and is not shaded during the day by tall plants, trees, other houses, hills, etc..
b
The installation of a solar water heating system modifies the existing structure of the roof. Verify the suitability of all roof elements and if necessary adapt them to avoid leaks or damage by wind and/or snow loads.
b
If the system is installed in an area subject to gusting winds or snow loads in excess of the limits given in the technical specifications, consult your supplier for advice.
b
Snow can build up in the sheltered area behind the solar water heating system. Provide adequate protection to avoid increasing the static load on the roof.
b
The system must be serviced at least once a year.
b
The water supply circuit must permit the storage cylinder to be filled and emptied in safety. Shut-off valves must therefore be easily accessible to the user and the operation of emptying the storage cylinder must not create any risk of flooding or other damage.
b
Insulate the domestic water pipes (hot and cold) and the pipes of the solar collector circuit. Provide suitable insulation for all outdoor accessories.
b
The point through which the water pipes enter the building must be rain-proof and damp-proof.
b
If you notice any water or heat transfer liquid leaks, disconnect the system immediately from the mains electricity supply (if a supplementary heating element is installed), shut off the water supply, and notify
T’s Technical Assistance Service or a
qualified heating engineer immediately.
b
Make sure that the water-glycol mix in the solar collector circuit is able to resist the minimum temperatures likely to occur in the place of installation.
b
The system can reach very high temperatures. Safety valves can therefore discharge extremely hot liquids. Make sure that the expansion vessel is of a suitable size and design for use in solar water heating systems.
b
Use proper slings to lift and move the elements of the system. Never lift the collector or storage cylinder by their fittings. Avoid subjecting the collector to impacts or mechanical strain, and take care to protect the glass panel. Use the personal protection equipment required by applicable safety standards.
PRECAUTIONS
a
Never attempt to install the system without using the personal protection equipment and without following the safety precautions specified by applicable occupational safety standards.
a
Never install solar collectors on roofs without an adequate lightning protection system.
a
Never install the system without providing proper drainage for the two safety valves: that of the domestic hot water circuit and that of the primary (solar collector) circuit.
a
If the storage cylinder is equipped with a supplementary heating element, never attempt any cleaning or maintenance without first disconnecting it from the mains power supply.
a
Do not allow children or infirm persons to operate the system unsupervised.
a
Do not tamper with or adjust the safety or control devices without prior authorisation and instructions from the manufacturer.
a
Never use anti-freeze other than that supplied by
T to fill or top up the solar collector circuit.
Mixing different products can reduce the anti-freeze protection provided.
a
Never drain the solar collector circuit under sunny conditions or when the collector is hot.
a
Do not dispose of packaging material into the environment, or leave it within the reach of children, since it can become a potential hazard. Dispose of packaging material in compliance with applicable legislation.
General
5
ENGLISH
GENERAL
DESCRIPTION OF THE SYSTEM
The
TSOL CN S BLU 30°
system is a solar hot water heating system that functions on the principle of natural circulation. The heat transfer liquid therefore circulates by normal convection. The system comprises one or more solar collectors and a jacket type storage cylinder, located under the collector/s. The system does not require any pumps or adjustments. A supplementary heating element is also available for use if needed.
The system comprises:
- Solar collector/s
- A jacket type solar storage cylinder
- Box of water pipes and fittings
- Mounting brackets
- Anti-freeze liquid.
SAFETY DEVICES
The system is equipped with the following safety devices:
- A primary circuit safety valve that opens if pressure in the primary (solar collector) circuit rises above a 2.5 bar threshold.
- A secondary circuit safety valve that opens if pressure in the secondary (DHW) circuit rises above a 10 bar threshold.
b
Water may come out of the primary and secondary circuit safety valves as a result of variations in temperature and pressure during the course of the day. Ensure that proper drainage is provided. For the same reason, avoid standing near the safety valves during the day.
b
Safety devices must only be replaced by T's Technical Assistance Service using original spare parts.
b
Over-temperature protection requires an adequate supply of cold water from the mains.
IDENTIFICATION
T
TSOL CN S BLU 30°
systems are identified by:
CODICE : 20075477
TIPO : CP20TSS
S/N :
COLLETTORE SOLARE PIANO
DIMENSIONI: 1818X1048X70 mm SUPERFICIE LORDA: 1,91 m
2
TEMPERATURA DI STAGNAZIONE: 192°C
SUPERFICIE DI APERTURA: 1,78 m
2
CONTENUTO LIQUIDO: 1,6 l
SUPERFICIE ASSORBITORE: 1,77 m
2
PESO A VUOTO: 34 kg LIQUIDO TERMOVETTORE:
ACQUA+GLICOLE PROPILENICO
MAX CONCENTRAZIONE GLICOLE: 50%
MAX PRESSIONE ESERCIZIO: 10 bar
FABBRICATO IN ITALIA
da Riello S.p.A.
20075510_E3
EN 12975
Certif. 011-7S2400F
13000000
BAR CODE 128B
Anno di produzione
SERIALE PROGRESSIVO
SISTEMA SOLARE A CIRCOLAZIONE NATURALE
NATURAL CIRCULATION SOLAR WATER HEATING SYSTEM
Serial N°
Mod.
bar
Anno
l
Cod.
Tipo/Type
bar
Year
Capacità bollitore
Storage cylinder capacity
Pressione di progetto acqua sanitaria
DHW circuit operating pressure
Pressione max circuito solare
Max solar heating circuit pressure
La protezione da sovratemperatura dipende dalla fornitura di acqua fredda sanitaria
Overr - t
emperat
ure
prot
ection require
s an adequate
supply of cold wate
r
T067781GE
RIELLO S.p.A. Via Ing. Pilade Riello, 7 - 37045 Legnago (VR)
Storage cylinder data plate
Collector data plate
b
If these plates or any other means of clearly identifying the product are defaced, removed or lost, proper installation and servicing may be rendered difficult.
6
ENGLISH
GENERAL
SYSTEM LAYOUT
3
4
30°
1
5
1
10
4
7
9 (*)
12
11
5
6
2
11
8
2
7
Components
1 Solar collector/s 2 Storage cylinder 3 Mounting frame
Pipes and ttings
4 Collector outlet 5 Collector return 6 Plug
External connections
7 Domestic cold water inlet - 3/4” 8 Domestic hot water outlet - 3/4” 9 Domestic cold water inlet cock 10 Filling/drain cock
Safety devices
11 Primary circuit safety valve (2.5 bar) 12 Non-return valve - Secondary circuit safety valve (10
bar)
(*) (Not supplied. To be provided by installer.)
POSSIBLE CONFIGURATIONS
TSOL CN S BLU 30°
150/1÷200/1
TSOL CN S BLU 30°
220/2÷300/2
TSOL CN S BLU 30°
300/3
TECHNICAL SPECIFICATIONS
Description
TSOL CN S BLU 30°
150/1 200/1 220/2 300/2 300/3
Collector surface area 1,91 x 1 1,91 x 1 1,91 x 2 1,91 x 2 1,91 x 3
m
2
x n.
of pan.
Exposed area 1,78 x 1 1,78 x 1 1,78 x 2 1,78 x 2 1,78 x 3
m
2
x n.
of pan.
Absorption area 1,77 x 1 1,77 x 1 1,77 x 2 1,77 x 2 1,77 x 3
m
2
x n.
of pan. Stagnation temperature 192 °C Storage cylinder capacity 153 202 223 278 278 l Magnesium anode 22 x 300 22 x 300 22 x 300 22 x 400 22 x 400 Ø x mm Heat transfer liquid capacity 8,5 13,6 16,3 20,3 22,2 l Maximum wind and snow load 2000 2000 2000 2000 2000 Pa DHW circuit safety valve operating pressure 10 bar Solar collector circuit safety valve operating pressure 2,5 bar A sol (*) 1,78 1,78 3,56 3,56 5,34 m
2
η0 (*)
0,778 0,778 0,778 0,778 0,778
a1 (*) 4,96 4,96 4,96 4,96 4,96 W/(m
2
K)
a2 (*) 0,0005 0,0005 0,0005 0,0005 0,0005 W/(m
2K2
)
IAM (50°) (*) 0,87 0,87 0,87 0,87 0,87
ηcol (**)
58 58 58 58 58 %
7
ENGLISH
GENERAL
Description
TSOL CN S BLU 30°
150/1 200/1 220/2 300/2 300/3
S 77 85 88 95 95 W V 153 202 223 278 278 I Qnonsol M (***) 1109 1132 1007 1044 1023 kWh/a Qnonsol L (***) 2122 2124 1711 1723 1494 kWh/a Qnonsol XL (***) 3610 3600 2977 2970 2527 kWh/a Qnonsol XXL (***) 4753 4738 4022 4008 3457 kWh/a
(*) Tested according to EN 12975, referred to a 33,3% water-glycol mix, flow rate of 140 l/h , and irradiation G = 800 W/m
2
.
Tm = (Coll._inlet _temp.+Coll._outlet_temp.)/2
T*m =
(Tm-T_ambient)/G
(**) Calculated with a temperature difference of 40K between the solar collector and the surrounding air, and with total solar
radiation of 1000 W/m
2
referred to the exposed area.
(***) Value calculated in terms of primary electrical energy and/or calorific content of fuel under average climatic conditions,
in load profiles M, L, XL and XXL, with permanent backup and storage cylinder inside building.
OVERALL DIMENSIONS AND WEIGHTS
L
P
H
30°
Description
TSOL CN S BLU 30°
150/1 200/1 220/2 300/2 300/3
Empty weight 112 136 162 198 236 kg Full weight 274 352 401 496 597 kg L 1310 1310 2400 2400 3500 mm P 2310 2310 2310 2310 2310 mm H 1130 1130 1130 1130 1130 mm
WATER CIRCUIT
UAC
Domestic hot water outlet
EAF
Domestic cold water inlet
1
Primary (solar collector) circuit safety valve (2.5 bar)
2
Non-return valve - safety valve of secondary (DHW) circuit (10 bar)
3
Storage cylinder
4
Collector
5
DHW tank (secondary circuit)
6
Primary circuit
7
Magnesium anode
8
Primary circuit filling/drain cock
9
Insulation
CWI
HWO
1
8
2
3
5
7
6
6
4
9
heat exchange
heat exchange
8
ENGLISH
INSTALLER
UNPACKING THE PRODUCT
Contents of packing:
- Solar collector/s
- Storage cylinder
- Box of accessories containing fittings and a container of glycol anti-freeze
- Mounting kit for flat roofs (see the assembly section for details of kit contents).
A plastic pouch containing:
- Instruction manual
- Bar code label
- Serial number plate.
b
This instruction manual is an integral part of the
TSOL
CN S BLU 30°
system. Once located, read it thoroughly
and keep it safe.
b
A protective lm is applied to the glass of the solar collector. On completion of installation, only remove this lm if you are going to put the system into service immediately.
b
Take care not to lose the four flat seal rings (1) located in the corner profiles of each collector.
1
Description
TSOL CN S BLU 30°
150/1 200/1 220/2 300/2 300/3
WEIGHT
Total weight of supply See the transport document kg COLLECTOR/S package 34 34 2 x 34 2 x 34 3 x 34 kg STORAGE CYLINDER package 62 76 84 106 116 kg
DIMENSIONS
Total supply package
2077 x 1246
x 770
2077 x 1246
x 770
2162 x 1246
x 870
2160 x 1250
x 870
2155 x 1246
x 870
mm
COLLECTOR/S package
1865 x 1200
x 95
1865 x 1200
x 95
2 x (1865 x
1200 x 95)
2 x (1865 x
1200 x 95)
3 x (1865 x
1200 x 95)
mm
STORAGE CYLINDER package
1250 x 600 x
600
1250 x 600 x
600
1250 x 600 x
600
2050 x 600 x
600
2050 x 600 x
600
mm
Installer
9
ENGLISH
INSTALLER
HANDLING
Hold solar collectors at the points shown (A) to move them. Lift and move the storage cylinder in a horizontal position. Make sure that the slings and lifting gear used are suitable for the weight.
A
A
A
A
a
Do not lift the solar collector by its water fittings.
a
Do not lift the storage cylinder by its water fittings.
b
Wear suitable personal protective equipment and use suitable safety devices.
PREPARING FOR INSTALLATION
Select the best possible orientation for the solar collectors (ideally facing south). Avoid positions that are shaded by plants, trees, buildings or hills, etc. during the day.
Maintain the minimum distance (A) between the system and the edge of the roof. Remove all gravel and detritus from the surface on which the system is to be installed.
The mounting kit must not be used to install other superstructures. It is designed only for use with T solar water heating systems.
The installation of a solar water heating system modifies the existing structure of the roof. Verify the suitability of all roof elements and if necessary adapt them to avoid leaks or damage by wind and/or snow loads.
> A
> A
TSOL CN S BLU 30°
U.M.
150/1 200/1 220/2 300/2 300/3
A 1 1 1,5 1,5 1 m
10
ENGLISH
INSTALLER
ASSEMBLY
Start installing the system by assembling the mounting frame for flat roofs. To do so, follow the instructions given below.
1
3
7
2
8
9
5
21 16 14 13 12 15 11
22 23 20 19 17 3418
10
4 6
25
26
27
28
30
31
32
29
24 33
Loading...