GENERAL INFORMATION
GENERAL INFORMATION
RANGE
MODEL CODE
TBSS 150 20124177 TBSS 200 20124178 TBSS 300 20124179 TBSS 430 20124180 TBSS 550 20124181 TBSS 800 20132275 TBSS 1000 20132276
ACCESSORIES
For a complete list of accessories and details of their compati­bility, refer to the Catalogue.
Dear heating engineer, We would like to congratulate you on having recommended a
T Storage cylinder unit: a modern product that's
capable of ensuring a high degree of reliability, efficiency, quality and safety. While your technical skills and knowledge will certainly be more than sufficient, this booklet contains all the information that we have deemed necessary for the device's correct and easy installation.
Thank you again, and keep up the good work,
Thermital
CONFORMITY
T storage cylinders conform to DIN 4753-3 and
UNI EN 12897 standards.
CONTENTS
The following symbols are used in this manual:
b
CAUTION! =
Identifies actions that require caution and
adequate preparation.
a
STOP! =
Identifies actions that you MUST NOT do.
GENERAL SAFETY INFORMATION
b
Check that the product is complete, undamaged and as ordered as soon as you receive it. Report any discrepan­cies or damage to the T dealer who sold it.
b
This product must be installed by a legally qualified heat­ing engineer. On completion of the installation, the install­er must issue the owner with a declaration of conformity confirming that the installation has been completed to the highest standards in compliance with the instructions provided by T in this instruction manual, and that it conforms to all applicable laws and standards.
b
This product must only be used for the purpose for which it is designed and made, as specified by
T.
T declines all responsibility, contractual or
other, for damage to property or injury to persons or ani­mals caused by improper installation, adjustment, main­tenance or use.
b
The product must be serviced at least once a year. Servic­ing must be arranged in advance with the T Technical Assistance Centre.
b
All servicing and repairs must be performed by a quali­fied heating engineer.
b
If water leaks from the storage cylinder, turn off the water supply and contact T’s Technical Assistance Centre or a qualified heating engineer immediately.
b
If the product is not going to be used for an extended period of time, contact the manufacturer’s Technical As­sistance Centre to have at least the following operations performed:
- Close the shut-off cocks for the domestic hot water cir­cuit
- Shut down the boiler connected to the storage cylinder as instructed in its own manual
- Switch the storage cylinder OFF at the control panel (if fitted) and at the mains power switch
- Drain the central heating circuit and domestic hot water circuit if there is any risk of freezing.
b
This instruction manual is an integral part of the prod­uct. It must be kept safe and must ALWAYS accompany the product, even if it is sold to another owner or trans­ferred to another user or to another installation. If you lose this manual, order a replacement immediately. Keep the product purchase documents to be presented to the
T authorised Technical Assistance Centre to
request a service call under warranty.
This manual, Code
- Rev. comprises pages.
ENGLISH
General information
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . 2
General Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . 2
Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Description of the appliance . . . . . . . . . . . . . . . . . . . . . . . . 3
Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Unpacking the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Assembly of the insulation and the lining (models 800 - 1000) . .
6
Place of installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation in older systems and systems requiring
modernisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Water quality requirements. . . . . . . . . . . . . . . . . . . . . . . . . . 6
Water connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Recycling and disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
END USER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Temporary shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Preparing for extended periods of disuse . . . . . . . . . . . . . . 8
External maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ENGLISH
GENERAL INFORMATION
GENERAL INFORMATION
PRECAUTIONS
The operation of any appliance that uses electrical power de­mands that a number of fundamental safety precautions be respected. In particular:
a
Never attempt to install the system without using suitable personal protection equipment and without following all applicable occupational safety standards.
a
Do not touch the product when barefoot or wet if it has any electrical accessories installed in it.
a
Never clean or service the storage cylinder without first turning the mains power switch OFF to disconnect all electrical accessories (if fitted) from the mains electricity supply.
a
Never pull, disconnect, or twist any electrical cables coming from the appliance even if it is disconnected from the mains electricity supply.
a
Do not expose the storage cylinder to the elements. It is not designed for use outdoors.
a
Do not allow children or infirm persons to operate the system unsupervised.
a
Do not dispose of packaging material into the environ­ment, or leave it within the reach of children, since it can become a potential hazard. Dispose of packaging mate­rial in compliance with applicable legislation.
DESCRIPTION OF THE APPLIANCE
T
TBSS
boilers produce domestic hot water for
storage purposes and are available in seven different models.
Their most important technical features are:
- the storage cylinder and coil are specially designed and shaped for optimum performance in terms of strati­fication, heat exchange and replenishment times
- internal glazing, bacteriologically inert, to ensure the maximum hygiene of treated water, reduce limescale deposits and make cleaning operations easier
- CFC-free polyurethane insulation and an elegant exter­nal casing reduce heat loss
- a flange is provided for easy cleaning and maintenance of the anti-corrosion magnesium anode.
IDENTIFICATION
The T
TBSS
solar heaters can be identified by:
Data plate
This lists the technical specifications and performance of the product.
BALLON
Modele Model
Fabrication
Code
Année
W
l
bar
W
kW
l/1'
BOLLITORE
Modello
Codice
Matricola
Anno
m
2
kW
T067850IFE
T067850IFE
BOILER
Serial number
Year
V-Hz
Potenza elettrica assorbita Puissance élect. absorbée Electrical consumption
Alimentazioneelettrica Alimentat. élect. Power supply
Dispersioni secondo EN 12897 Déperditions selon EN 12897 Heat loss according to EN 12897
Matricola Fabrication Serial number
Modello Modele Model
Max pot. assorb. Puiss. absor. Power abs.
Code
Massima potenza assorbita [T° Primario 80°C] Puissance absorbée serpentin [T° Primaire 80°C] Power absorbed by the coil [T° primary 80°C]
Produzione acqua calda sanitaria - serp. [∆T20°C] Production eau chaude sanitaire - serp. [∆T 20°C]
Domestic hot water production – coil [∆T 20°C]
Superficie serpentino Surface serpentin Coil heat exchange surface area
Press. esercizio max. Pression service max. Maximum working pressure of storage cylinder
Capacità del bollitore Capacité ballon Storage cylinder capacity
Collegamento di terraobbligatorio - Raccordement a la terre obligatoire
Obligatory ground connection
RIELLO S.p.A. Via Ing.Pilade Riello 7 37045 Legnago (VR) - ITALY
RIELLO S.p.A. Via Ing.Pilade Riello 7 37045 Legnago (VR) - ITALY
Serial number plate
This specifies the serial number and model.
b
If these plates or any other means of clearly identify­ing the product are defaced, removed or lost, proper installation and servicing may be rendered difficult.
b
On models 800 and 1000 the technical data plate and serial number plate must be applied (by the installer) after the insulation has been fitted.
SYSTEM LAYOUT
UAC
EAF
SB
P
M
1
3
6
5
4
2
1
Storage cylinder
2
Preset for lifting han­dles (accessory) and/ or device grounding point
3
Coil
4
Flange for heater in­spection
5
Insulation
6
Cover
P
Socket
M
Guide
UAC
Domestic hot water
outlet
EAF
Domestic cold water
inlet
SB
Storage cylinder drain
Loading...