Therma-Tru Doors Troubleshooting

SITE 4 Troubleshooting
Air and/or Light Leak at Top or Bottom
of Jamb ............................................................... 4.3
Water Leakage Around or Under Sill ...............4.4
Water Leakage Around
Door/System Perimeters ................................... 4.6
Water Leakage Around Lites ............................4.7
Water Leakage Around
Fiber-Classic Designline Panels ...................... 4.8
Door Will Not Open or Close Properly .............4.9
Spring Loaded Hinge
Adjustment Instructions ................................. 4.10
Panels are Loose or Have Come Off. ............. 4.11
Miniblinds Does Not Operate Properly .......... 4.12
Trouble Shooting
SITE 4 2014 4.1
Trouble Shooting
4.2 2014 SITE 4
Air and/or Light
Leak at Top or Bottom of Jamb
PROBLEM: Air and/or light leak at top or bottom of jamb.
Cause
Weatherstrip missing.
Weatherstrip painted.
Weatherstrip cracked, torn or damaged.
Bottom corner seal pads missing or removed.
Door loose in frame, with excessive in-and-out movement when latched.
Solution
Replace weatherstrip.
Replace pads.
Adjust strike plate for tighter fit.
Refer to…
Site 5 - Weatherstrip Replacement
SHOP Frame Assembly Sections
SITE 1 - Pre-hung Unit Installation for Adjustable Sills
SITE 1 Corner Seal Pad Instructions
SITE 1 - Pre-hung Unit Installation
Trouble Shooting
Door not meeting weatherstrip evenly when it closes, hitting the top or bottom first.
Realign, reshim, readjust lockside jamb so door meets weatherstrip evenly from top to bottom.
SITE 1 - Pre-hung Unit Installation
SITE 4 2014 4.3
Water Leakage Around or Under Sill
PROBLEM: Water leakage around or under sill.
Door not meeting weatherstrip evenly when it closes, hitting the top to bottom first.
Damaged or painted weatherstrip.
Improper/insufficient sealant and/or sealant breakdown between sill and subfloor.
Broken seal where the sill meets the jamb.
Sill humped or depressed beyond range of door bottom’s sealing capacity.
Trouble Shooting
Cause
Solution
Realign, reshim, readjust lockside jamb so door meets weatherstrip evenly from top to bottom.
Replace weatherstrip.
Reseal under sill using Elastomeric and Polyurethane sealant.
Remove corner seal pad, pull out weatherstrip at bottom, and place a bead of Elastomeric and Polyurethane sealant along entire joint where jamb and sill meet. Replace weatherstrip and reapply corner seal pad.
Anchor sill to draw down straight by drilling pilot holes and securing with galvanized screws.
Replace any wrinkled/torn door bottom.
Refer to…
SITE 1 - Pre-hung Unit Installation
SITE 5 - Weatherstrip Replacement
SITE 1 - Pre-hung Unit Installation
SITE 1 - Pre-hung Unit Installation
Humped sill.
Damaged sill saddle causing door bottom bulb seal to bunch up and wrinkle when the unit closes.
Shim jamb legs up to allow sill to straighten. Reseal with Elastomeric and Polyurethane sealant under sill and anchor sill in place.
Replace the saddle and screw down.
SITE 5 - Adjustable Sill Threshold Replacement
4.4 2014 SITE 4
Loading...