Make sure the walls, ceiling and floor materials are suitable for use with steam. If using acrylic walls, they must be steam
rated from their manufacturer. ThermaSol only recommends specific generators for acrylic modules. Ensure electrical power
is turned off for the duration of the installation.
PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS
PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFER FROM
HEART DISEASE, AND INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS “ON”, UP TO ONE HOUR AFTER IT HAS SHUT OFF.
SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE ON POSITION. SEVERE BURNS WILL OCCUR.
DO NOT USE THERMASOL AROMATHERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT
CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE
OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM EMITTING FROM THE
STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY.
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM.
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT.
THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES.
THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME.
o Pipe compound
o Copper or brass fittings & nipples
(sizes and quantities per instructions)
o Wire (see page 3)
o Copper tube or pipe
o Wire cap nuts
o Flex conduit
50 foot
control cable
Parts enclosed with the generator:
In-line water screen kit
warranty, static cling
warning label
o Brass or copper tee connection and plug
o Silicone
o Other materials as required
o Drain Pan
Materials recommended:
o In-line water filter (recommended)
o Brass Union
Tools needed:
o Pipe wrench
(comes pre-installed from the
factory) Item 04-8457
Control Kit
(purchased separately)
o Tubing cutter
o Wire cutters or wire strippers
o Adjustable wrench
o Screwdriver (Phillips and regular)
o Solder and flux
o 1-1/16" inch masonry drill bit
o 7/8" inch hole saw for
deluxe steamhead
o Drill motor
o Propane torch
o Other tools as required
2
THERMASOL.COM I 800.776.0711
BY THERMASOL
Steam Suite Spa Package
3Sizing or Double Checking the Unit Specified
If you are installing the unit or thinking of adding one on your next
project, you will need to make sure the unit is sized properly.
Calculate the shower area
(Length x Width x Height = Cubic Feet)
and confirm the ceiling height does not exceed 8 feet.
The set of numbers in the generator model number
represents the maximum capacity.
Model number can be found on the box or generator.
ThermaSol’s generators can be placed up to 50 feet from the
shower; in an attic, closet or below a sink are ideal locations.
Make sure the walls, ceiling and floor materials are suitable
for use with steam.
Installation note
We do not recommend a
ceiling height exceeding
10 feet. Lowering ceiling
height to 8 feet helps
create a more efficient
steam room
.
4Electrical Wiring
The size of the shower will determine the size
of the generator. The size of the generator will
determine electrical requirements.
MODEL INPUT VOLTAGE KW RATING AMPS PHASE WIRE BREAKER MAX. ROOM SIZE
ThermaSol requires that a licensed electrician perform all electrical work.
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
o All the electrical wiring must be done per
National/Local Electrical Codes.
o Run 240V Power source to the generator.
o Use copper wire only.
o Wire sizes recommended by NEC. Minimum wire
temperature rating 90°C. Type THHN.
o Each generator should be wired to their own separate breaker.
o Turn off all electricity to the working area at the main breaker panel!
o Leave power OFF during installation process.
THERMASOL.COM I 800.776.0711
3
BY THERMASOL
Steam Suite Spa Package
5Placing the Generator
Select a location as near as practical to the steam shower.
Typical locations include: closet, vanity cabinet, climate
controlled attic or basement.
Be sure to install unit in a location that offers easy
accessibility for servicing of generator.
DO NOT install generator inside steam room.
DO NOT install generator or plumbing lines in unheated
attic or any locations where water could freeze.
DO NOT install generator outdoors or wherever
environmental conditions may affect the safety
and/or performance of the generator.
Example of different
generator locations.
Generator may be installed up to 50 feet away from steam
shower and must be in a dry, non-combustible, well
ventilated space with 6" clearance around generator.
When constructing the ceiling add slope of 1"/foot. The
control cable provided with the generator is 50 feet in
length (Item 03-6152-050).
When locating the control unit, place it as far as possible
away from the steam head and as close as is practical to
where the user will be sitting.
The generator must be upright, accessible and on a
level surface with all connections on top. Access panel
must be unobstructed and allow for easy access.
Installed in
nearby vanity
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
4
Installed in
nearby closet
THERMASOL.COM I 800.776.0711
BY THERMASOL
Steam Suite Spa Package
6Water Supply and Drain Pan
Once you select the generator location,
you will need to run water to the unit.
DO NOT use galvanized fittings. Use copper or brass fittings only!
DO NOT use PEX or PVC tubing.
DO NOT plumb the pressure relief valve into the steam line.
Plumbing the pressure relief valve into the steam line can be
hazardous, should the steam outlet be capped off or obstructed.
Recommend installing unions on all rigid pipe lines for ease of
removal and serviceability (if required).
Use 3/8" NPT line.
A
Plumb the 3/4" drain connection on pan to an approved drain.
B
Drain Pan must be installed on all generator installations.
All plumbing shall be performed by a qualified
licensed plumber and in accordance with
applicable national and local codes.
Connect a tee to the existing cold water line.
C
Install copper pipe from the tee to create inlet line for unit.
Install a brass shut off valve on the water inlet line
D
in an accessible area in front of the brass union (and
recommended in-line water filter). A stainless steel water
supply flex connector may be used.
Before making the water connection, flush the water line
E
into a five-gallon pail to remove any silt or other materials that
may be in the water inlet line.
Make final connection but DO NOT turn the water on yet.
Water Inlet Line
(3/8" NPT with brass
shut-off valve)
AD
C
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
E
B
THERMASOL.COM I 800.776.0711
3/4" Drain Line
Steam Line
5
BY THERMASOL
Steam Suite Generator
7Steam Line and Steamhead
Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the
steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself.
DO NOT install any valve in the steam line. Flow of steam must
be unobstructed.
DO NOT plumb any traps in the steam line.
The steam outlet on the generator requires a 1/2" brass
A
union for easy installation (not included).
Use 1/2” brass pipe or copper tubing from unit to
B
steamhead rough-in fitting as permitted by code.
A
Shown installed
in attic
The steam line can run up and then down, once; or horizontal;
but never run down and then up. If it does, a steam trap will
be produced at the low point blocking the flow of steam.
Insulate the steam outlet piping if the piping run exceeds 10 feet or
is exposed to cold areas. Use steam rated insulation.
Pitch/angle steam lines back towards generator before any up or
down turns; pitch/angle towards steam room after any up or down
and avoid perfectly level plumbed lines.