Thermasol SS-84, SS-140, SS-240, SS-395, SS-600 Installation Instructions Manual

Installation Instructions
Steam Shower Series
With Fast Start Technology
Manufacture Post 2005
If you are a plumber installing this unit, please leave
this owners manual & warranty card with the owner
This Instruction supercedes all previous information provided by ThermaSol
Thank You!
CONSUMER WARNING
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO.
USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS “ON”, UP TO ONE HOUR FROM THE
TIME THE UNIT IS OFF. SEVERE BURN WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
NEVER ATTEMPT TO FILL AROMA THERAPY RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE “ON” POSITION. SEVERE
BURNS WILL OCCUR.
DO NOT USE THERMASOL AROMA THERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT IN CONJUNCTION WITH YOUR
THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER
REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS, OR PHYSICAL INJURY.
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR
HEALTH.
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM.
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT.
Note: Before contacting Customer Service for Technical Support, please have the model number, serial number and date code (located on a circle to the lower right of the serial number), include all numbers and letters.
Headquarters & Technical Support
2255 Union Place, Simi Valley, CA 93065 – (800) 776-0711
Mon – Thur 7:00 – 5:00, Fri 8:00 – 12:00 PST
Eastern Sales Office
26 Industrial Avenue, Fairview, NJ 07022 – (800) 631-1601
Mon – Thur 7:00 – 5:00, Fri 8:00 – 12:00 EST
www.thermasol.com
DOC NO. 81078 Page 1 of 18 Rev D 3/06 GM
** NOTICE **
WARNING LABEL
THERMASOL STEAMHEAD
SHOWER FLOOR
THERMASOL
CONTROL
YOU MUST ATTACH THIS STATIC
CLING USER WARNING LABEL IN THE
SHOWER NEXT TO THE CONTROL
UPON COMPLETION OF
DOC NO. 81078 Page 2 of 18 Rev D 3/06 GM
INSTALLATION
Generator Installation Instructions
Parts Enclosed
NoTouch Steamhead housing
Steam generator
50 foot control cord
Test kit with Instructions
Installation Instructions
Warranty card
Static cling warning label
All ThermaSol steam generators are designed to build NO PRESSURE for your safety.
Note: Failure to follow installation instructions specifically will cause the warranty to be void.
CONTROL CABLE
INPUT
ELECTRICAL BOX
POWERFLUSH BALL
RELIEF VALVE
during operation. This is
PRESSURE
12” AT
PIPING
POWERFLUSH BALL VALVE
IN CLOSED POSITION
IDENTIFICATION LABEL
11-1/2”
FRONT OF GENERATOR
(ACCESS PANEL)
WATER
INLET
17”
Figure 1
Note: The generator must be mounted level with all connections on top.
DOC NO. 81078 Page 3 of 18 Rev D 3/06 GM
Generator Installation Instructions (con’t)
Materials Needed
Brass ball valve (for water supply shut off)
Pipe compound
Copper or brass fittings & nipples (sizes and quantities per instructions)
In-line water filter (recommended)
3/8” brass or copper union
1/2” brass or copper union
Wire (sizes and quantities per instructions)
Copper tubing or pipe
Wire cap nuts
Flex conduit
Silicone
Other materials as required
Tools Needed
Pipe wrench
Tubing cutter
Wire cutters or wire strippers
Adjustable wrench
Screwdrivers (phillips & regular)
Solder & Flux
1-1/16” masonry drill bit
2-1/2” hole saw for NoTouch Steamhead
Drill motor
Propane torch
Other tools as required
Note: ThermaSol steam bath generators are for indoor use only. They should never be located outside the home.
Note: ThermaSol steam bath generators are NOT designed to be used for space heating purposes.
Warning: Please consult your physician before using. If you are pregnant, elderly, have high blood pressure, diabetes, suffering from heart disease, intoxicated, or not in good health, do not use this steam bath.
DOC NO. 81078 Page 4 of 18 Rev D 3/06 GM
CONSUMER WARNING
WARNING
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTO R A ND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
WARNING
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE ON POSITION. SEVERE BURNS WILL OCCUR.
WARNING
DO NOT USE THERMASOL AROMA THERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT IN CONJUNCTION WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
WARNING
YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS, OR PHYSICAL INJURY.
WARNING
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS “ON”, UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURN WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
WARNING
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRU GS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH.
WARNING
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM.
WARNING
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT.
DOC NO. 81078 Page 5 of 18 Rev D 3/06 GM
Requirements For Proper Installation
1. Ensure the steam room to be used is vapor proof. It should have a vapor proof door that seals well so the steam does not escape. Make sure the walls, ceiling and floor materials are suitable for use with steam and hot condensation, the steam produces.
2. Unit may be installed up to 50 feet away from steam room in a dry well ventilated area.
3. Use copper or brass fittings only (NEVER USE GALVANIZED FITTINGS).
4. The water inlet uses 3/8” NPT and steam outlet uses 1/2" NPT for easy installation.
5. The generator must be upright, accessible and on a level surface panel and powerflush valve must be unobstructed and allow for easy access (see Figure 1).
6. Place a drain/spill pan under the unit. Plumb the connection on it to an approved drain.
7. Connect a tee to the cold water line. Install copper pipe to the tee (see Figure 3).
8. Install a brass shut-off valve on the water inlet line in an accessible area prior to the bra ss union and recommended in-line water filter.
9. Before making the last connection to the 3/8” NPT, flush the water line into a five-gallon pail to remove any silt or other materials that may be in the line.
10. Make the final connection and turn on water. All ThermaSol generators are equipped with an automatic water fill system. The water will stop after unit is filled.
11. The steam line can run up, down, or horizontal; but cannot run down and then up steam trap will be produced at the low point blocking the flow of steam. Do not steam line. Insulate the steam outlet piping if the piping run exceeds 10 feet or is exposed to cold areas. Note: Use steam rated insulation.
12. Do not the steam line can be hazardous, should the steam outlet be capped off or obstructed.
13. Pitch/angle steam line back towards generator and avoid perfectly level plumbed lines
14. Make sure water is turned on before operating the unit.
Note: Failure to follow installation instructions specifically will cause the warranty to be void.
plumb the pressure relief valve into the steam line. Plumbing the pressure relief valve into
with all connections on top. Access
. If it does, a
plumb a trap in the
.
Sizing Your Steam Room
Factory Sized: L x W x H = Cubic Feet
Then choose the appropriate Model. No complicated formulas. It’s that simple. For every foot of ceiling height over 8 ft. (always round up) use the next larger steam unit. Wall material irrelevant.
Generator
Model
SS-Acrylic
SS-84 84 6.0 SS-140 140 8.0 SS-240 240 10 SS-395 395 12 SS-600 500 15
Factory Sized
Cu Ft MAX KW
Acrylic Insert
3.5
DOC NO. 81078 Page 6 of 18 Rev D 3/06 GM
Loading...
+ 12 hidden pages