Thermasol PRO SERIES Installation Instructions Manual

Installation Instructions
PRO SERIES
If you are a plumber installing this unit, please leave this owners manual &
y card with the owner when you finish the installation.
WARNING
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAM HEAD FROM THE TIME THE UNIT IS “ON”, UP TO ONE HOUR FROM THE TIME THE UNIT IS OFF. SEVERE BURN WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAM HEAD OR STEAM EMITTING FROM THE STEAM HEAD.
NEVER ATTEMPT TO FILL AROMA THERAPY RESERVOIR ON THE STEAM HEAD WHEN UNIT IS IN THE “ON” POSITION. SEVERE BURNS WILL OCCUR.
DO NOT USE THERMASOL AROMA THERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT IN CONJUNCTION WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR TILE MANUFACTURER RE GARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAM HEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAM HEAD WILL CAUSE SERIOUS BURNS, OR PHYSICAL INJURY.
Note: Before contacting Customer Service for Technical Support, please have the model number and serial number (including all numbers and letters) located on the unit.
Headquarters & Technical Support
2255 Union Place, Simi Valley, CA 93065 – (800) 776-0711
Eastern Sales Office
26 Industrial Avenue, Fairview NJ 07022 – (800) 631-1601
www.thermasol.com
Thank You!
DOC NO. 81060 1 OF 18 RevA 06/01/03
Sizing Your Steam room
Sizing: 1. Calculate the total volume of the enclosure. (Length x Width x Height = Total Volume).
2. Using the Volume total, multiply by the number to the right of your shower wall material shown below.
Example: 7 ft. long x 4 ft. wide 7 ft. high = 196 cubic feet 196 cubic ft. x 1.65 (marble) = 323.4 cubic ft. = Model PRO-300 generator.
NOTE: Add 10% for every foot exceeding 7 ft. in ceiling height. Add 10% for every exterior outside wall.
Fiberglass, Cultured Marble .65Corian No ChangeCeramic tile on waterproof sheetrock, cement bed or mortar bed No ChangeAll glass tile, glass block walls 1.35Natural stone tiles 3/8” to ½” (marble, travertine, slate, granite, etc.) 1.65Natural stone tiles on cement bed or mortal bed 1.65Natural stone slab ¾” to 1” 1.85
For further assistance call toll-free 800-776-0711
DOC NO. 81060 2 OF 18 RevA 06/01/03
Generator Installation Instructions
Parts Enclosed
No Touch steam head housing
Steam generator
50 Foot control cord
Installation instructions
All ThermaSol steam generators are designed to build NO PRESSURE This is for your safety.
NOTE: Failure to follow installation instructions specifically will cause the
warranty to be void.
during operation.
Power Cord
Control Input
Smitty pan drain connection
Steam Outlet
Water Inlet
DOC NO. 81060 3 OF 18 RevA 06/01/03
Fi
gure 1
Generator Installation Instructions (continued)
Materials Needed
Brass ball valve
Pipe compound
In-line filter (recommended)
Wire (PRO-700 only)
Copper tubing or pipe
Wire cap nuts (PRO-700 only)
Flex conduit (PRO-700 only)
Brass or copper tee connection & plug
Silicone
Tools Needed
Pipe wrench
Tubing cutter
Wire cutters or wire strippers
Adjustable wrench
Screwdrivers (phillips & regular)
Solder & Flux
1” & 1
2.5” hole saw for No Touch steam head
Drill motor
Propane Torch
Other tools as required
WARNING: Please consult your physician before using. If you are pregnant,
1
/16” masonry drill bits
NOTE:
Thermasol steam bath generators are for indoor use only. They should never be located outside the home.
Thermasol steam bath generators are NOT designed to be used for space heating purposes.
elderly, have high blood pressure, diabetes, suffering from heart disease, intoxicated, or not in good health, do not use this steam bath.
DOC NO. 81060 4 OF 18 RevA 06/01/03
CONSUMER WARNING
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
WARNING
WARNING
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAM HEAD WHEN UNIT IS IN THE ON POSITION. SEVERE BURNS WILL OCCUR.
WARNING
DO NOT USE THERMASOL AROMA THERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT IN CONJUNCTION WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
WARNING
YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAM HEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAM HEAD WILL CAUSE SERIOUS BURNS, OR PHYSICAL INJURY.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAM HEAD FROM THE TIME THE UNIT IS “ON”, UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURN WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAM HEAD OR STEAM EMITTING FROM THE STEAM HEAD.
DOC NO. 81060 5 OF 18 RevA 06/01/03
WARNING
Requirements for proper installation
1. Ensure the enclosure to be used is vapor proof. It should have a vapor proof door that seals
well so the steam does not escape. Make sure the wall, ceiling and the floor materials are ok to use with steam and hot condensation, the steam produces.
2. Use copper or brass fittings only. (NEVER USE GALVANIZED FITTINGS)
3. The water inlet uses flex hose and steam outlet uses a brass union for easy
installation. Install the drain/spill pan under the unit.
4. The generator must be upright, accessible and on a level surface with all connections on
top. Access panel must be unobstructed and allow for easy access. See figure 1.
5. Unit may be installed up to 50 feet away from shower area. In a dry well ventilated area.
6. Do not
Plumbing the pressure relief valve into the steam line can be hazardous, should the steam outlet be capped off or obstructed.
7. Pitch steam line back towards generator and avoid perfectly level plumbed lines
8. Before connecting water line to the generator, flush water line into a five-gallon pail to remove
any silt or other materials that may be in the line. An in-line water filter is also recommended.
9. Make sure water is turned on to the unit before operating the unit.
NOTE: Failure to follow specific installation instructions will cause the warranty to be void.
plumb a trap in the steam line or plumb the pressure relief valve into the steam line.
.
Figure 2
Various options for the ThermaSol steam bath generator location.
DOC NO. 81060 6 OF 18 RevA 06/01/03