Make sure the walls, ceiling and oor materials are suitable for use with steam. If using acrylic walls, they must be steam
rated from their manufacturer. ThermaSol only recommends specic generators for acrylic modules. Ensure electrical power
is turned off for the duration of the installation.
PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS
PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFER FROM
HEART DISEASE, AND INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS “ON”, UP TO ONE HOUR AFTER IT HAS SHUT OFF.
SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE ON POSITION. SEVERE BURNS WILL OCCUR.
DO NOT USE THERMASOL AROMATHERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT
CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE
OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM EMITTING FROM THE
STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY.
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM.
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT.
THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES.
THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME.
q Wire (see page 3)
q Copper tube or pipe
q Wire cap nuts
q Flex conduit
(for units 12kW and above)
3/8" Hose & Fitting
(Items 02-8239 & 04-1810)
Parts enclosed with the generator:
In-line water screen kit
warranty, static cling
warning label
q Brass or copper tee connection and plug
q Silicone
q Other materials as required
Materials recommended:
q In-line water lter (recommended)
q PRO-750 and PRO-1000:
(2) 1/2" - 3/4” drop elbow/adapters
Tools needed:
q Pipe wrench
q Tubing cutter
(comes pre-installed from the
factory) Item 04-8457
Steamhead Housing and
Cable Kit (10-8034-1)
q Wire cutters or wire strippers
q Adjustable wrench
q Screwdriver (Phillips and regular)
q Solder and ux
q 1-1/16" inch masonry drill bit
q 1-1/8" inch hole saw for ThermaSol
SteamVection steamhead rough-in
q Drill motor
q Propane torch
q Other tools as required
Read warnings on page 2. For illustrative purposes only. Consult with qualied professional for steam room construction details.
2
THERMASOL.COM I 800.776.0711
PRO Series Generator Installation Instructions
3Sizing or Double Checking the Unit Specied
If you are installing the unit or thinking of adding one on your next project,
you will need to make sure the unit is sized properly.
Calculate the shower area
(Length x Width x Height = Cubic Feet)
The set of numbers in the generator model number
represents the maximum capacity.
Example: Generator model PRO-240 will be sufcient
up to 240 cubic feet (with a ceiling not exceeding
8 feet in height). Up-size 1 Unit size for every foot
over 8 foot to a maximum of 10 foot.
Model number can be found on the box or generator.
Installation note
We do not recommend a
ceiling height exceeding
10 feet.
Lowering ceiling
height to 8 feet helps
create a more efcient
steam room.
ThermaSol’s generators can be placed up to 50 feet from the
shower; in an attic, closet or below a sink are ideal locations.
Make sure the walls, ceiling and oor materials are suitable
for use with steam.
q All the electrical wiring must be done per National/Local Electrical Codes.
4Electrical Wiring
The size of the shower will determine the size
of the generator. The size of the generator will
determine electrical requirements.
q Run 240V Power source to the generator.
q Use copper wire only.
q Wire sizes recommended by NEC (2002 Version). Minimum wire
temperature rating 90°C. Type THHN.
q Each generator should be wired to their own separate breaker
8'
4'
5'
q Turn off all electricity to the working area at the main breaker panel!
q Leave power OFF during installation process.
MODEL INPUT VOLTAGE KW RATING AMPS PHASE WIRE BREAKER ELECTRICAL MAX. ROOM SIZE
Be sure to install unit in a location that offers easy
accessibility for servicing of generator. (Power Flush
maintenance is recommended every 1000 minutes
of use.)
DO NOT install generator inside steam room.
DO NOT install generator or plumbing lines in unheated
attic or any locations where water could freeze.
DO NOT install generator outdoors or wherever
environmental conditions may affect the safety
and/or performance of the generator.
Generator may be installed up to 50 feet away from steam
shower and must be in a dry, non-combustible, well
ventilated space with 6" clearance around generator.
When constructing the ceiling add slope of 1"/foot. The
control cable provided with the generator is 50 feet in
length (Item 03-6152-050).
When locating the control unit, place it as far as possible
away from the steam head and as close as is practical to
where the user will be sitting.
The generator must be upright, accessible and on a
level surface with all connections on top. Access panel
must be unobstructed and allow for easy access.
Example of different
generator locations.
4
Read warnings on page 2. For illustrative purposes only. Consult with qualied professional for steam room construction details.
THERMASOL.COM I 800.776.0711
PRO Series Generator Installation Instructions
6Water Supply and Drain Pan
Once you select the generator location,
you will need to run water to the unit.
Use copper or brass ttings only!
DO NOT use galvanized ttings.
DO NOT use PEX or PVC tubing.
DO NOT plumb the pressure relief valve into the steam line.
Plumbing the pressure relief valve into the steam line can be
hazardous, should the steam outlet be capped off or obstructed.
Recommend installing unions on all rigid pipe lines for ease of
removal and serviceability (if required).
Use 3/8" NPT line to connect to supplied 3/8" braided hose.
A
B
The drain pan is required for installation.
Plumb the 3/4" drain connection on pan to an approved
C
drain.
generator installations.
All plumbing shall be performed by a qualied
licensed plumber and in accordance with
applicable national and local codes.
Drain Pan must be installed on all
Connect a tee to the existing cold water line.
D
Install copper pipe from the tee to create inlet line for unit.
Install a brass shut off valve on the water inlet line
E
in an accessible area in front of the brass union (and
recommended in-line water lter). A stainless steel water
supply ex connector may be used.
Pre-Installed water line debris screen (included) in the
F
water inlet on the generator.
Before making the water connection, ush the water line
into a ve-gallon pail to remove any silt or other materials
that may be in the water inlet line.
Make nal connection but DO NOT turn the water
or power on yet.
Water Inlet Line
(3/8" NPT with brass
shut-off valve)
3/4" Drain Line
E
AD
Steam Line
F
B
C
Read warnings on page 2. For illustrative purposes only. Consult with qualied professional for steam room construction details.
THERMASOL.COM I 800.776.0711