7
• The maximum tank pressure is 6 bar.
• Be careful when fixing the fitings to hot and cold water connections, as they do not
have a high tensile strength.
• This product complies with the applicable safety standards. If it show defects, stop
using it and have it checked by the manufacturer.
• If the device is licking water, it must be switched off and controlled by qualified
personnel that can perform the checking and repairing;
• Faulty repairs or performed by unqualified personnel can cause risks to persons or
and invalidate the warranty .
• The higher the temperature of the room where you instal WABO is, the lower power
consumption you’ll need;
• Above and below the unit must be left sufficient space for maintenance.
• Do not install in humid and unventilated places;
• Do not install in areas where there may be temperatures below zero;
• Do not leave it exposed to the rain,wind or any weather agents;
• Do not install the product on power lines without protection from surges or variations;
• For the safety of the device is necessary to provide a bipolar switch (contacts at least
3 mm);
• Do not install the product on power lines without differential circuit breaker;
• It is mandatory to connect the device to the ground;
• Make sure the wall mount can support the weight of the product and its water content;
• The hydraulic connection requires the connecting of a drain cock and a valve for
excessive pressure (8 bar) on the cold water manifold;
• It is recommended the providing of a drain able to eliminate the water on the exit of
the valve.
• Before plugging the device fill the tank and check if there are eventually water leaks;
• For a better and more rational exploitation of Carbon Boiler we recommend the
installation of a thermostatic valve for manual adjustment of the water temperature
at exit;
• We recommend installing a device to compensate for the increased volume of heated
water (expansion vessel);
• We also recommend the installation of an input pressure regulator group and a water
treatment system.