Thermaltake W0156 Specifications

80 PLUS Verification and Testing Report
V
V
V
TYPICAL EFFICIENCY (50% Load): AVERAGE EFFICIENCY : 80 PLUS COMPLIANT:
Ecos ID # Manufacturer Model Number Serial Number Year Type Test Date
Rated Specifications
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz. Input AC Current Waveform (ITHD = 5.53%, 50% Load)
I
RMS
A
2.56 0.99 9.2% 20%
6.07 1.00 5.5% 50%
12.37 1.00 3.4% 100%
Rated Output Power
PF
667 THERMALTAKE W0156 Toughpower 1200 AP NA 2008 ATX12V & EPS12V 5/19/2008
Input Voltage Input Current
Input Frequency
I
THD
Load
(%) Input
(%)
Fraction of Load
Light
Typical
Full
alue Units
47-63 Hz
Watts
291 11.9/0.1 3.3/4.9 5/4.9 5/0.6 241 696 12/0.3 3.2/12.2 5/12.2 4.9/1.4 597
1421 12.2/0.7 3.1/24.3 4.8/24.5 4.7/2.9 1172
85.77%
83.73% YES
15 Amps
1200 Watts
DC Terminal Voltage (V)/ DC Load Current (A)
12V (cumulative of 12V1, 12V2, etc.)
12/16.3 12/40.7
11.8/81.3
Input Current and Voltage Waveforms
0
0 0.003 0.006 0.009 0.012 0.015
Time (s)
Voltage Current
3.3
5V* 5VSB
Voltage (V)
-12
200 150 100
50
-50
-100
-150
-200
Output
Watts
20 15 10 5 0
-5
-10
-15
-20
Efficiency
82.97%
85.77%
82.46%
Current (A)
%
1600
1400
1200
1000
800
600
Power (Watts)
400
200
0
20% 50% 100%
Input and Output Power
Input Watts
Output Watts
Loading (% of Rated Output Power)
These tests were conducted as a part of the 80 PLUS program. 80 PLUS is a computer buy-down program to promote high-efficiency power supplies (greater than 80% efficiency in the active mode) in desktop computers and desktop-derived servers.
Tested by Electric Power Research Institute, Knoxville, TN.
90%
80%
70%
60%
Efficiency (%)
50%
40%
30%
0% 25% 50% 75% 100% 125%
Efficiency of the Power Supply
Efficiency %
Loading (% of Rated Output Power)