BrandThermaltake
Manufacturer (OEM)Channel Well Technology
SeriesToughpower
Model NumberTPD-1200F3FAPU-1 (Sample #1)
Serial NumberPSTPD1200F3FAPU1LU000020
DUT Notes
POWER SPECIFICATIONS
Rail3.3V5V12V5VSB-12V
Amps252510030.3
Max. Power
Watts1301200153.6
Total Max. Power (W)1200
DUT SPECIFICATIONS
Rated Voltage (Vrms)100-240
Rated Current (Arms)14
Rated Frequency (Hz)50-60
Rated Power (W)1200
TypeATX12V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 2
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Thermaltake TPD-1200F3FAPU-1 (Sample
Evaluation Report
#1)
General Data
Manufacturer (OEM)CWT
PCB TypeDouble Sided
Primary Side
Transient Filter6x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush ProtectionNTC Thermistor & Relay
Bridge Rectifier(s)2xHY Electronic GBJ2506P (600V, 25A @ 100°C)
APFC MOSFETS2x Toshiba TK25A60X (600V, 25A @ 153°C, 0.125Ohm), 1x Sync Power SPN5003 FET (for reduced no-load consumption)
APFC Boost Diode2x CREE C3D10060A (600V, 10A @ 153°C)
Hold-up Cap(s)2x Nippon Chemi-Con (400V, 680uF each or 1,360uF combined, 2000h @ 105°C,KMW)
Main Switchers4x Oriental Semiconductor OSG55R160FZ (550V, 14.5A @ 100°C, 0.16Ohm)
IC Driver2xSilicon Labs Si8233BD
APFC ControllerTexas Instruments UCD3138A
Resonant ControllersTexas Instruments UCD3138A
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 3
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Thermaltake TPD-1200F3FAPU-1 (Sample
Evaluation Report
RESULTS
Test Date06-19-2019
Certification Date06-24-2019
Cybenetics ID #738
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency89.793
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V66.687
Average Efficiency 5VSB76.962
Standby Power Consumption (W) -115V0.0439574
Standby Power Consumption (W) -230V0.0746642
Average PF0.994
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Avg Noise Output38.21
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-S+
#1)
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 4
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Thermaltake TPD-1200F3FAPU-1 (Sample
Evaluation Report
EFFICIENCY GRAPH
#1)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 5
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Thermaltake TPD-1200F3FAPU-1 (Sample
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.225
1
5.000V0.330115.13V
0.090A0.450
2
4.997V0.613115.13V
0.550A2.744
3
4.988V3.527115.13V
1.000A4.980
4
4.979V6.463115.13V
1.500A7.456
5
4.970V9.681115.13V
3.000A14.819
6
4.939V19.366115.12V
DC/AC
(Watts)
EfficiencyPF/AC Volts
68.182%
73.409%
77.800%
77.054%
77.017%
76.521%
0.026
0.049
0.233
0.340
0.406
0.490
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.225
1
4.999V0.362230.31V
0.090A0.450
2
4.998V0.648230.31V
0.550A2.744
3
4.988V3.583230.31V
1.000A4.980
4
4.979V6.457230.31V
1.500A7.456
5
4.969V9.654230.31V
3.000A14.819
6
4.939V19.174230.31V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.009
62.155%
0.016
69.444%
0.083
76.584%
0.142
77.126%
0.198
77.232%
0.311
77.287%
#1)
VAMPIRE POWER -115V
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 6
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Thermaltake TPD-1200F3FAPU-1 (Sample
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
#1)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 7
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Thermaltake TPD-1200F3FAPU-1 (Sample
Evaluation Report
10-110% LOAD TESTS
Test
#
1
2
3
4
5
6
12V5V3.3V5VSB
8.207A1.968A2.003A0.986A120.189
12.011V5.086V3.297V5.073V136.95639.14°C115.14V
17.410A2.953A3.003A1.184A239.854
12.002V5.082V3.294V5.067V262.66040.26°C115.14V
26.948A3.447A3.492A1.383A359.348
11.999V5.078V3.292V5.061V391.78451.27°C115.14V
36.539A3.943A4.011A1.583A479.779
12.003V5.074V3.289V5.055V522.45051.84°C115.14V
45.791A4.932A5.019A1.783A599.900
11.998V5.070V3.286V5.049V652.87052.72°C115.14V
55.020A5.924A6.034A1.983A720.048
12.000V5.065V3.282V5.043V789.91953.75°C115.16V
DC/AC
(Watts)
Fan
Efficiency
87.757%0<6.0
91.317%0<6.0
91.721%158142.1
91.833%158942.1
91.887%128435.1
91.155%160541.5
Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
48.19°C0.981
49.72°C0.994
41.50°C0.997
41.79°C0.998
42.37°C0.998
42.76°C0.998
PF/AC
Volts
#1)
7
8
9
10
11
CL1
CL2
64.235A6.918A7.044A2.184A839.802
90.669%161141.5
11.998V5.061V3.279V5.037V926.23154.54°C115.18V
73.521A7.912A8.058A2.385A960.293
90.073%161741.6
11.995V5.057V3.276V5.031V1066.12255.74°C115.18V
83.167A8.414A8.555A2.387A1079.610
89.468%162041.6
11.989V5.053V3.273V5.029V1206.70256.84°C115.12V
92.672A8.915A9.082A2.992A1200.107
88.581%162541.8
11.982V5.049V3.270V5.014V1354.81158.81°C115.14V
102.739A8.923A9.087A2.994A1320.118
87.763%162541.8
11.976V5.045V3.268V5.011V1504.19360.64°C115.16V
0.158A16.002A16.000A0.000A135.489
81.927%158542.1
11.994V5.071V3.278V5.103V165.37852.52°C115.13V
100.036A1.004A1.000A1.000A1212.736
88.907%162341.7
11.989V5.056V3.284V5.045V1364.05058.53°C115.15V
43.02°C0.998
43.82°C0.998
44.15°C0.998
45.75°C0.998
46.59°C0.997
42.01°C0.977
45.61°C0.998
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 9
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Thermaltake TPD-1200F3FAPU-1 (Sample
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)18.0
AC Loss to PWR_OK Hold Up Time (ms)18.6
PWR_OK Inactive to DC Loss Delay (ms)-0.6
#1)
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.