All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 1/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 2
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Thermaltake TTP-850AH2FKP
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency90.030%
Efficiency With 10W (≤500W) or 2% (>500W)73.495
Average Efficiency 5VSB80.111%
Standby Power Consumption (W)0.0554739
Average PF0.983
Avg Noise Output29.24 dB(A)
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-A-
230V
Average Efficiency92.101%
Average Efficiency 5VSB79.826%
Standby Power Consumption (W)0.0786161
Average PF0.929
Avg Noise Output28.45 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A-
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)18.7
AC Loss to PWR_OK Hold Up Time (ms)17.8
PWR_OK Inactive to DC Loss Delay (ms)0.9
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 3
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Thermaltake TTP-850AH2FKP
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 4
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Thermaltake TTP-850AH2FKP
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.231
68.750%
5.123V0.336115.13V
0.090A0.461
74.959%
5.120V0.615115.12V
0.550A2.801
81.165%
5.091V3.451115.12V
1.000A5.062
81.435%
5.062V6.216115.12V
1.500A7.542
81.010%
5.027V9.310115.12V
2.500A12.399
78.272%
4.960V15.841115.12V
0.039
0.069
0.269
0.346
0.388
0.433
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.231
64.167%
5.123V0.360230.29V
0.090A0.461
72.144%
5.120V0.639230.29V
0.550A2.800
80.298%
5.090V3.487230.29V
1.000A5.061
80.653%
5.060V6.275230.29V
1.500A7.541
81.008%
5.027V9.309230.30V
2.500A12.397
80.063%
4.958V15.484230.30V
0.012
0.022
0.111
0.179
0.232
0.300
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 5
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Thermaltake TTP-850AH2FKP
115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 6
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 115V
Thermaltake TTP-850AH2FKP
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 115V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 6/15
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 7
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -115V
Thermaltake TTP-850AH2FKP
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 7/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 8
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 115V
Test #12V5V3.3V5VSB
5.263A1.982A1.987A0.992A84.975
1
12.041V5.046V3.322V5.041V96.46940.01°C115.14V
11.554A2.975A2.985A1.197A170.060
2
12.044V5.043V3.316V5.014V186.88240.86°C115.14V
18.178A3.473A3.487A1.404A255.069
3
12.048V5.041V3.313V4.987V277.42141.48°C115.14V
24.808A3.972A3.990A1.613A340.087
4
12.048V5.037V3.306V4.961V369.48946.64°C115.13V
31.052A4.968A4.997A1.825A425.096
5
12.063V5.034V3.303V4.932V465.60647.78°C115.12V
DC/AC
(Watts)
Thermaltake TTP-850AH2FKP
Efficiency
88.085%0<6.0
90.999%0<6.0
91.943%0<6.0
92.043%5896.3
91.300%5886.3
Fan Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.51°C0.949
44.80°C0.978
45.90°C0.988
41.58°C0.992
42.11°C0.995
PF/AC
Volts
6
7
37.281A5.964A6.003A2.000A509.411
12.065V5.031V3.298V4.906V561.06049.21°C115.12V
43.601A6.963A7.015A2.257A594.899
90.794%87519.0
90.113%1263
42.64°C0.996
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 10
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Thermaltake TTP-850AH2FKP
230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 10/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 11
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH 230V
Thermaltake TTP-850AH2FKP
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
PAGE 11/15
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 12
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
VAMPIRE POWER -230V
Thermaltake TTP-850AH2FKP
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 12/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 13
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS 230V
Test #12V5V3.3V5VSB
5.258A1.981A1.987A0.992A84.976
1
12.054V5.046V3.321V5.041V95.16640.01°C230.28V
11.546A2.972A2.986A1.197A170.067
2
12.054V5.043V3.316V5.014V183.45041.02°C230.28V
18.173A3.472A3.488A1.403A255.089
3
12.053V5.040V3.312V4.988V272.76247.37°C230.28V
24.802A3.973A3.992A1.613A340.110
4
12.051V5.037V3.308V4.962V362.67348.20°C230.27V
31.074A4.968A4.996A1.824A425.135
5
12.056V5.034V3.302V4.935V456.09050.00°C230.28V
DC/AC
(Watts)
Thermaltake TTP-850AH2FKP
Efficiency
89.292%0<6.0
92.705%0<6.0
93.521%484<6.0
93.779%5866.1
93.213%5886.3
Fan Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
44.51°C0.713
46.37°C0.877
41.20°C0.934
41.52°C0.956
42.18°C0.967
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
37.298A5.965A6.007A2.000A509.487
92.928%85718.2
12.061V5.031V3.297V4.911V548.26150.83°C230.27V
43.617A6.964A7.020A2.255A594.963
92.491%123930.7
12.056V5.027V3.291V4.881V643.26952.48°C230.27V
49.957A7.967A8.038A2.476A680.319
91.980%170139.9
12.048V5.023V3.286V4.849V739.63853.25°C230.28V
56.656A8.470A8.536A2.482A765.239
91.593%179841.1
12.050V5.020V3.281V4.838V835.48054.27°C230.28V
63.280A8.972A9.065A2.597A849.949
91.140%180241.1
12.053V5.018V3.277V4.816V932.57755.73°C230.27V
70.297A8.977A9.072A2.604A934.727
90.611%216246.0
12.056V5.015V3.274V4.802V1031.58757.86°C230.27V
0.101A12.005A12.000A0.000A101.170
85.700%5856.1
12.085V5.034V3.293V5.087V118.05150.55°C230.27V
70.018A1.000A1.001A1.000A857.553
91.787%180141.4
12.058V5.027V3.299V4.947V934.28455.68°C230.27V
42.60°C0.973
43.40°C0.978
43.64°C0.982
44.31°C0.985
45.09°C0.987
47.06°C0.989
42.55°C0.785
45.22°C0.987
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 14/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 15
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
Thermaltake TTP-850AH2FKP
CERTIFICATIONS 115V
CERTIFICATIONS 230V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 15/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.