BrandThermaltake
Manufacturer (OEM)Channel Well Technology
SeriesToughpower
Model NumberTPD-0850F3FAGU-1
Serial NumberPSTPD0850F3FAGU1UE000021
DUT Notes
DUT SPECIFICATIONS
Rated Voltage (Vrms)100-240
Rated Current (Arms)12
Rated Frequency (Hz)47-63
Rated Power (W)850
TypeATX12V
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 2
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Thermaltake TPD-0850F3FAGU-1
General Data
Manufacturer (OEM)CWT
PCB TypeDouble Sided
Primary Side
Transient Filter4x Y caps, 2x X caps, 2x CM chokes, 1x MOV, 1x Discharge IC
Inrush ProtectionNTC Thermistor & Relay
Bridge Rectifier(s)1xGBU1506 (600V, 15A @ 100°C)
APFC MOSFETS2x Infineon IPA60R125P6 (650V, 19A @ 100°C, 0.125Ohm)
APFC Boost Diode1x Infineon IDH08G65C5 (650V, 8A @ 145°C)
Hold-up Cap(s)2x Nippon Chemi-Con (400V, 470uF each or 940uF combined, 2000h @ 105°C,KMR)
Main Switchers2x Toshiba TK25A60X5 (600V, 25A @ 150°C, 0.14Ohm)
APFC ControllerChampion CM6502UHHX& CM03X Green PFC Controller
Resonant ControllersChampion CM6901X
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 3
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Thermaltake TPD-0850F3FAGU-1
RESULTS
Test Date05-28-2019
Certification Date06-25-2019
Cybenetics ID #740
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency89.228
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V70.579
Average Efficiency 5VSB78.029
Standby Power Consumption (W) -115V0.0482677
Standby Power Consumption (W) -230V0.0648953
Average PF0.980
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Avg Noise Output34.77
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-S++
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 4
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Thermaltake TPD-0850F3FAGU-1
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 5
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.229
1
5.077V0.330115.09V
0.090A0.457
2
5.076V0.613115.10V
0.550A2.785
3
5.062V3.504115.08V
1.000A5.050
4
5.049V6.375115.08V
1.500A7.553
5
5.035V9.614115.08V
DC/AC
(Watts)
EfficiencyPF/AC Volts
69.394%
74.551%
79.481%
79.216%
78.563%
0.034
0.062
0.265
0.357
0.410
Thermaltake TPD-0850F3FAGU-1
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.229
1
5.077V0.351230.21V
0.090A0.457
2
5.076V0.640230.21V
0.550A2.785
3
5.062V3.569230.21V
1.000A5.050
4
5.049V6.442230.21V
1.500A7.549
5
5.032V9.651230.21V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.011
65.242%
0.020
71.406%
0.102
78.033%
0.170
78.392%
0.229
78.220%
6
3.000A14.972
4.991V19.602115.09V
VAMPIRE POWER -115V
76.380%
0.475
6
3.000A14.969
76.835%
4.989V19.482230.21V
0.333
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 6
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Thermaltake TPD-0850F3FAGU-1
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 7
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test
#
1
2
3
4
5
12V5V3.3V5VSB
5.248A1.983A2.000A0.991A84.879
12.059V5.044V3.296V5.045V96.35139.85°C115.10V
11.492A2.976A3.006A1.192A169.384
12.051V5.039V3.292V5.036V185.96940.83°C115.10V
18.142A3.475A3.495A1.393A254.473
12.043V5.035V3.288V5.026V277.29441.35°C115.10V
24.804A3.976A4.017A1.594A339.669
12.033V5.032V3.285V5.018V370.53950.14°C115.10V
31.141A4.974A5.026A1.797A424.969
12.025V5.027V3.281V5.010V465.96451.43°C115.10V
DC/AC
(Watts)
Thermaltake TPD-0850F3FAGU-1
Fan
Efficiency
88.094%0<6.0
91.082%0<6.0
91.770%0<6.0
91.669%58311.3
91.202%58211.3
Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
46.83°C0.965
48.31°C0.980
49.22°C0.983
41.56°C0.980
42.25°C0.979
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
37.421A5.975A6.043A2.000A509.500
89.901%106330.4
12.017V5.023V3.276V5.001V566.73752.56°C115.10V
43.785A6.977A7.059A2.204A594.830
89.192%144238.0
12.007V5.017V3.272V4.992V666.91253.64°C115.10V
50.154A7.983A8.080A2.409A680.159
88.398%165743.1
11.998V5.012V3.267V4.983V769.42554.81°C115.10V
56.928A8.489A8.579A2.410A765.075
87.730%165643.1
11.990V5.008V3.263V4.980V872.08355.69°C115.10V
63.445A8.995A9.112A3.026A849.907
86.789%165943.1
11.982V5.004V3.259V4.958V979.28057.60°C115.10V
70.553A9.000A9.122A3.028A934.666
85.851%165843.1
11.976V5.002V3.256V4.955V1088.70458.97°C115.10V
0.145A14.004A13.998A0.000A117.835
83.476%64213.9
12.047V5.013V3.278V5.070V141.16151.69°C115.11V
70.842A1.002A0.998A1.000A862.791
87.403%165843.1
11.991V5.025V3.271V5.025V987.14657.07°C115.10V
42.84°C0.980
43.38°C0.982
43.98°C0.983
44.27°C0.985
45.78°C0.987
46.58°C0.988
42.20°C0.976
45.65°C0.987
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Page 9
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)18.60
AC Loss to PWR_OK Hold Up Time (ms)17.40
PWR_OK Inactive to DC Loss Delay (ms)1.20
Thermaltake TPD-0850F3FAGU-1
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...