THERMAL DYNAMICS CM 39 / CM 10 Troubleshooting instruction

TECHNICAL
BULLETIN
Date: 03/23/2009 Product: CM 39 / CM 10 By: Jorge Santana Subject: CutMaster 39 and CutMaster 10 Summary: AC light flashing
Valued Thermadyne Service Provider
It just come to our attention that some time ago the vendor that supply us with the fans for the CutMaster 39 and the CutMaster 10 changed its specification slightly … the new fans stop drawing current for approximately 40ms when the unit is first turned on. This situation may be interpreted by the main board as a problem with the fan and the AC light will begin to flash.
In most cases the problem is resolved by simply turning the unit off and back on. An alternative option is to remove D14 from the Main PCB ( just clip it off from the board) and apply RTV to the
exposed terminals. Removal of D14 will defeat the current measuring circuit for the fan and it will not affect th e functionality of the unit.
The following page shows the location of diode (D14) in the main PCBoard. Note. All the Cut Masters 39 and CutMasters 10 manufactured after January 15, 2009 have D14 removed from the
Main board.
Please do not hesitate to contact us if you have any questions.
For More information Contact:
THERMAL DYNAMICS TECHNICAL SUPPORT
Phone: 1-800-752-7622 Fax: 1-603-298-7402 tdc-tech@thermadyne.com
www.thermadyne.com
Form 0007
West Lebanon, NH 03784
“Exceeding Customer Expectations Through Performance Excellence"
82 Benning Street
1-603-298-5711
Fax: 1-800-221-4401
TECHNICAL
BULLETIN
Date: 03/23/2009 Product: CM 39 / CM 10 By: Jorge Santana Subject: CutMaster 39 and CutMaster 10 Summary: AC light flashing
Remove D14
For More information Contact:
THERMAL DYNAMICS TECHNICAL SUPPORT
Phone: 1-800-752-7622 Fax: 1-603-298-7402 tdc-tech@thermadyne.com
www.thermadyne.com