Thermador TCMTK30RS Installation Manual

Installation
Instructions
TCMTK30RS BUILT-IN COFFEE MAKER TRIM KIT
THERMADOR.COM
Table of
Safety
Contents
Safety ......................................................................................2
Important Safety Instructions..........................................2
Installation Instructions...........................................................3
Before You Begin............................................................3
General Dimensions........................................................3
Cabinet Cutout Dimensions............................................3
Flush Install Dimensions..................................................4
Standard Installation .......................................................4
®
THERMADOR
Support ................................... back page
Definitions
9 WARNING
This indicates that death or serious injuries may occur as a result of non-observance of this warning.
9 CAUTION
This indicates that minor or moderate injuries may occur as a result of non-observance of this warning.
NOTICE: This indicates that damage to the appliance or property may occur as a result of non-compliance with this advisory.
Note: This alerts you to important information and/or tips.
Page. 1
This THERMADOR® appliance is made by
1901 Main Street, Suite 600
Irvine, CA 92614
Questions?
1-800-735-4328
www.thermador.com
We look forward to hearing from you!

Safety

IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS

INSTALLER: Please leave these instructions with this unit for the owner. Show the owner the location of the circuit breaker or fuse. Mark it for easy reference.

OWNER: Please retain these instructions for future reference.

WARNING

When properly cared for, your new appliance has been designed to be safe and reliable. Read all instructions carefully before use. These precautions will reduce the risk of burns, electric shock, fire and injury to persons. When using kitchen appliances, basic safety precautions must be followed, including those in the following pages.

WARNING

DO NOT repair or replace any part of the appliance unless specifically recommended in the manuals. Improper installation, service or maintenance can cause injury or property damage. All other servicing should be done by an authorized servicer.
WARNING State of California Proposition 65 Warning:
This product can expose you to chemicals including vinyl chloride, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov.
APPLIANCE HANDLING SAFETY

CAUTION

It is recommended to have two installers to install the coffee maker. Failure to do so may result in property damage or personal injury.
Hidden surfaces may have sharp edges. Use caution when reaching behind or under appliance.
It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.
ELECTRIC SAFETY
Before you plug in an electrical cord, be sure all controls are in the OFF position.
For appliances equipped with a cord and plug, DO NOT cut or remove the ground prong. It must be plugged into a matching grounding type receptacle to avoid electrical shock. If there is any doubt as to whether the wall receptacle is properly grounded, the customer should have it checked by a qualified electrician.
If required by the National Electrical Code (or Canadian Electrical Code), this appliance must be installed on a separate branch circuit.
Be sure your appliance is properly installed and grounded by a qualified electrician. Installation, electrical connections and grounding must comply with all applicable codes.
RELATED EQUIPMENT SAFETY
Remove all tape and packaging before using the appliance. Destroy the packaging after unpacking the appliance. Never allow children to play with packaging material.
Never modify or alter the construction of the appliance. For example, do not remove leveling legs, panels, wire covers or anti-tip brackets/screws.
GROUNDING INSTRUCTIONS

WARNING

Improper grounding can result in a risk of electric shock.
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
Page. 2

Installation Instructions

29¾" (755)
13
¾" (349)
14
¾" (374)
17 (449)
11
/16
"
23½" (596)
22" (558)
17
⅞"
(455)
19
⅝"
(498)
inches (mm)
28½"28½"28½" (724)
(724)(724)
19
" – 23½"
(504 – 597)
19⅞" – 23½"
(504 – 597)
19⅞" – 23½"
(504 – 597)
19
¼
"
(488)
inches (mm)
Before You Begin
Trim Kits
Trim kits are designed for use ONLY with the Thermador Built-in Coffee Maker models TCM24RS.
IMPORTANT: The Built-in Coffee Maker installation instructions can be found in the Built-in Coffee Maker Assembly. The coffee maker must be installed according to the instructions in the Installation Manual. If the instructions are not followed, this may result in unsatisfactory installation or unit performance.
Tools Needed
Phillips head screwdriver
T-20 Torx screwdriver
Measuring tape
Drill with bits (1/16'')
Screws Included with the Coffee Maker Trim Kit
14 x
#8 x ¾'' wood Screw (Phillips)
General Dimensions
Cabinet Cutout Dimensions
7 x
4 x
Items Used Included with TCM24RS Coffee Maker
1 x
4 x
Spacer
M4 x 25mm Screw (T20 Torx)
#10 x ½ Screw (T20 Torx)
Shims
Page. 3
Flush Install Dimensions
*
Top View
Side View
reveal cleats
20
⅛"
(511) ush
cut-out
height
ush inset
depth
¾" (19)¾" (19)
reveal cleats
reveal cleats
1" (25)
1"
(25)
28
½" (724)
30" (762)
19⅞" – 23½"
(504 – 597)
19⅞" – 23½"
(504 – 597)
19⅞" – 23½"
(504 – 597)
19
" – 23½"
(504 – 597)
19⅞" – 23½"
(504 – 597)
19⅞" – 23½"
(504 – 597)
inches (mm)
dia. 1/16"
1
2
dia. 1/16"
1
2
1" (41)1" (41)1" (41)
dia. 1/16"
1
2
2. Install the Right Cabinet Mounting Bracket at the top right of the cabinet opening using two (2) ¾'' Phillips head wood screws. Ensure the bracket is flush to the
cabinet side and cabinet face.
NOTE: * Flush installation requires a 5/16'' (8 mm) high x 28 underneath the unit body.
Standard Installation
1. Install the Left Cabinet Mounting Bracket at the top
½'' (724 mm) wide x 22½'' (571 mm) deep baseplate
left of the cabinet opening using two (2) ¾'' Phillips head wood screws. Ensure the bracket is flush to the
cabinet side and cabinet face.
3. Measure 1
'' (41 mm) from cabinet base and make
mark on both sides of cabinet.
4. Install the Left and Right Side Cabinet Brackets flush to the cabinet face with two (2) ¾'' Phillips head wood screws per side. Install side trim mounting bracket so that the bottom edge of the bracket is aligned with
mark.
Page. 4
5. Secure the Left Side Mounting Bracket to the Base
CCC
LL
dia. 1/16"
1
Plate using three (3) T-20 x
½'' Torx head screws.
6. Center the Base Plate in the cabinet cavity using the center locating notch. Secure the Base Plate to the
cabinet floor with six (6)
¾” wood screws.
8. Set the Coffee Maker Transformer behind the Base Plate. Install and plug transformer according to the
Coffee Maker instructions.
9. Plug the transformer plug into the back of the coffee maker, as instructed in the Coffee Maker Installation Instructions. Slide coffee maker in cabinet on top of the Base Plate and move coffee maker to the left so
the left side is flush with the Left Support Bracket.
7. Secure the Left Side Mounting Bracket to the Left Cabinet Mounting Bracket at the top left of the
cabinet using one (1) T-20 x
Page. 5
½'' Torx head screw.
10. Open the coffee maker door. Secure the Left Support Bracket from the inside of the coffee maker using six
(6) x 1'' T-20 Torx head screws.
11. Use a 1'' T-20 Torx screw with spacer (shipped with
1mm 2mm
3mm
4mm
coffee maker) to secure the top right corner of the coffee maker.
12. If the door does not shut smoothly, check to see if the Door Latch is hitting on the top or bottom or the
receiver.
13. If the latch is hitting on the bottom, pull the coffee maker out and install the 1mm Shim, included with the coffee maker, at the bottom left side of the coffee maker.
If the receiver is hitting on the top, install the 1mm Shim on the top left of the coffee maker.
14. Reinstall the coffee maker. If the receiver hits again increase the shim size until the Door Latch no longer hits.
15. Press the Built-in Coffee Maker Trim Kit into the left and right Side Cabinet Brackets.