Thermador HS30BS User Manual

PLANNING GUIDE
VENTILATION
VENTILATION QUICK REFERENCE CHART
Quick Reference Chart for Recommended Ventilation Based On Cooking System
Updraft Ventilation Options
1
Downdraft Ventilation Options
2
Cook ‘N’ Vent
Minimum CFM Wall
3
Island
3
Universal
Recommended for Cooktops
MODEL SERIES HSB HCSW HS HDW PH_Z HGSI HDI PHI_Z
Wall Island HSW HST PHE HTDI HNI CVS2 UCV
HTSW HNW HTNI
HGSW
Gas or Electric Cooktops 300 400 II III III I I
30" Downdraft Ranges 600 600
30" Free-standing or
400 600
II III II
Slide-in Updraft Ranges
Professional-style Ranges or cooktops for home 1000 1400
II
applications
1
Updraft Width Guidelines:
The minimum hood width recommended for wall installation equals the cooktop or range width. Where space is not restricted, a wider hood can be used to increase your capture area. Island installations require a greater capture area, therefore the hoods used should overlap your appliance by a minimum of 3"- 6" on either side.
2
Cook ‘N’ Vent 2 Width Guidelines:
The Cook ‘N’ Vent 2 system selected should match the width of your cooktop. Thermador offers 30", 36"or 45" widths. Due to the high performance requirements of Professional-style appliances for the home, an overhead hood is highly recommended.
3
Available Ceiling Height:
Before selecting your updraft hood, check your available installation space. This is determined by adding your floor-to­countertop height, plus the recommended spacing between your appliance and the bottom of the hood, plus the height of the hood. See product dimensions on pages 75-83.
NOTE: Indoor Gas Grills:
The local codes may require a fire-rated construction for installation of open gas grill appliances. Please check with your local codes prior to installation.
For immediate critical installation dimensions by fax, use your fax handset and call (775)833-3600. Use code #8030 for a directory of Thermador®products.
VENTILATORS
VCK300 VM410 VTN420B VTN620B VTN1000Q
Integral (Mounted on Hood) Ventilator Options
Maximum CFM: 300
Electrical Motor Rating
2.4 Amps @ 120 V AC, 60 Hz
Recommended Duct Size
3
1
/4" x 10"
Use in Control Housing
VCK1
Use in Hood Series
N/A
Maximum CFM: 390
Electrical Motor Rating
1.5 Amps @ 120 V AC, 60 Hz
Recommended Duct Size
3
1
/4" x 10"
Use in Control Housing
VCH8
Use in Hood Series
N/A
Maximum CFM: 1000
Electrical Motor Rating
5 Amps @ 120 V AC, 60 Hz
Recommended Duct Size
10" round
Use in Control Housing
N/A
Use in Hood Series
Option for PH Series, wall models only
Maximum CFM: 400
Electrical Motor Rating
2.0 Amps @ 120 V AC, 60 Hz
Recommended Duct Size
8" round
Use in Control Housing
N/A
Use in Hood Series
Standard in HSB Series; option for HS or HST series
Maximum CFM: 600
Electrical Motor Rating
4.0 Amps @ 120 V AC, 60 Hz
Recommended Duct Size
8" round
Use in Control Housing
N/A
Use in Hood Series
Option for HS or HST Series
VTR600R VTR1000Q VTR1400Q
Remote (Roof or External Wall) Ventilator Options
Maximum CFM: 600
Electrical Motor Rating
4.3 Amps @ 120 V AC, 60 Hz
Duct Size at Intake
8" round
Use in Control Housing
VCK1, VCH8, VCH36
Use in Hood Series
Option for HS or HST Series
Maximum CFM: 1000
Electrical Motor Rating
7.8 Amps @ 120 V AC, 60 Hz
Duct Size at Intake
10" round
Use in Control Housing
VCH36, VCH54*
Use in Hood Series
Option for HS, HST, HNI, HNW, HTNI or PH Series
Note: Heavy-duty backdraft damper included**
Maximum CFM: 1400
Electrical Motor Rating
12.8 Amps @ 120 V AC, 60 Hz
Duct Size at Intake
10" round
Use in Control Housing
VCH36, VCH54*
Use in Hood Series
Option for HNI, HNW, HTNI, PH or PHI Series
Note: Heavy-duty backdraft damper included**
*When using the VCH54 control housing, you will also need a plenum (Model PLENUM) duct accessory. **No roof jack or wall cap required. Collar extends below mounting flange into roof or wall installation area.
Ventilators are UL and CUL approved.
93/4"
8"
7
3
/4"
12
3
/4"
8"
71/2"
235/8"
8"
235/8"
8"
251/8"
10
3
/4"
3
1
/2"
28"
8"
20
3
/4"
5
7
/8"
14
5
/8"
24"
26
1
/4"
17
5
/8"
5
7
/8"
20
3
/4"
10"
28"
4"
26
1
/4"
10"
28"
20
3
/4"
17
5
/8"
14"
4"
8
1
/4"
8
1
/8"
Control Housings are UL and CUL approved.
CONTROL HOUSINGS FOR CUSTOM HOOD APPLICATIONS
VCK1 VCH8 VCH36 VCH54
Finish
Black enamel with chrome reflector lights
Application
Shallow custom hood or kitchen cabinet
Lighting
Accepts two 60-watt bulbs
Controls
Solid-state infinite speed control and rotary light switch
Notes:
1. Only 4
1
/8" exposed below
cabinet cutout.
2. Lamps not included.
Finish
Satin finish with removable single aluminum mesh filter screens
Application
For nonprofessional-style cooktops/ranges
Lighting
Accepts two 75-watt flood lamps
Controls
Solid-state infinite speed control
Notes:
1. Filter and lamp shields snap out for easy cleaning.
2. Lamps not included.
Finish
Satin finish with removable single aluminum mesh filter screen
Application
Use with high heat applications in custom hoods of 36" width or greater
Lighting
Accepts two 75-watt flood lamps
Controls
Requires separate wall­mounted switches* for lights and ventilator
Notes:
1. Filter and lamp shields snap out for easy cleaning.
2. Lamps not included.
Finish
Satin finish with removable dual aluminum mesh filter screens
Application
Use with high heat applications in custom hoods of 54" width or greater
Lighting
Accepts three 75-watt flood lamps
Controls
Requires separate wall-mounted switches* for lights and ventilator
Notes:
1. Filter and lamp shields snap out for easy cleaning.
2. Lamps not included.
3. Double filter housing for superior performance.
4. Requires PLENUM (sold separately from Thermador).
Internal Mounted VCK300
Remote Mounted VTR600R
Internal Mounted VM410
Remote Mounted VTR600R
Internal Mounted N/A
Remote Mounted VTR600R, VTR1000Q,
VTR1400Q
Internal Mounted N/A
Remote Mounted VTR1000Q, VTR1400Q
Recommended Thermador Ventilators
**
**Ventilator performance shown on page 75.
*Requires standard wall switch for light, plus Thermador CTRQ-3, three-speed ventilator control switch.
101/2"
26
7
/8"
9
5
/16"
11
15
/16"
29
3
/4"
9
3
/8"
11
15
/16"
35
3
/4"
9
3
/8"
11
15
/16"
53
3
/4"
9
3
/8"
For immediate critical installation dimensions by fax, use your fax handset and call (775)833-3600. Use code #8030 for a directory of Thermador®products.
Loading...