Thermador® ExtraLow™ and Traditional Series Cooktops
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS
AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.
IMPORTANT: Save these instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Power Supply: 120 volts, 15 Ampere,
60 Hz., Natural Gas - 5 inch water
column, Propane Gas - 10 inch water
column.
WARNING: Disconnect power before
installing or servicing. Before turning power ON, be sure that all controls are in the OFF position.
IMPORTANT INSTALLATION INFORMATION
Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual. For assistance or additional information consult a qualified
installer, service agency, manufacturer (dealer) or the
gas supplier.
This appliance has been tested in accordance with
ANSI Z21.1Current Issue, Standard for Household
Cooking Appliances (USA) and in accordance with CAN
1.1-M81 Domestic Gas Ranges (CANADIAN).
Check your local building codes for the proper method
of installation. In the U.S., if there are no applicable local
codes, this unit should be installed in accordance with the
National Fuel GAS Code #Z223.1-1990, and the National Electrical Code
ANSI/NFPA No. 70 Current Issue. (In Canada, installation must be in
accordance with the CAN 1-B149.1 and .2 – Installation Codes for Gas
Burning Appliances and/or local codes.)
Be sure the unit being installed is correct for the type of gas being used.
The cooktop is shipped from the factory for use with natural gas. Conversion for use with propane gas can be made using a kit, Model NLPKIT5,
P/N 35-00-622. A qualified technician or installer can convert the cooktop.
This kit includes instructions for adjusting valves and regulator and
contains new burner jets.
This appliance is equipped with an intermittent/interrupted ignition
device.
! CAUTION:
▲
(1) When connecting the
unit to propane gas make
certain the propane gas
tank is equipped with its
own high pressure regulator in addition to the
pressure regulator supplied inside this unit. The
maximum gas pressure to
this appliance is not to
exceed 14.0 inches water
column from the propane
gas tank regulator.
Do not attempt to connect
propane gas without first
installing conversion kit,
Model NLPKIT5, P/N 3500-622. A qualified service
technician or installer can
convert the cooktop.
(2) This unit is designed
as a cooking appliance.
Based on safety consideration never use it for
warming or heating a
room.
•Thermador recommends use of a
ducted hood over this cooktop.
•Minimize cross drafts that can
be created by adjacent open
windows, doors, air conditioning, heating vents, recessed
ceiling lights, etc.
Cabinet Considerations
•This unit is designed for
installation in a countertop
near adjacent walls and projecting surfaces constructed of
combustible materials. There
must be a minimum clearance
of 30 inches between the top of
the cooking surface and the
bottom of the unprotected wood
or metal cabinet; or 24 inches
when bottom of wood or metal
2
upper cabinets
18" Min.
Wall
3" Min. - no
Cabinet Depth from
Back Wall is 13" Max.
Hood Depth 24" Max.
30" Min.
centered over
Cooktop
Models GGS30,
SGS30,GGN30 &
SGN30
36" Min.
centered over
Cooktop
30" min.
Models GGS36/
365,SGS36G,
GGN36/365 &
SGN36G
3" Min. - no
upper cabinets
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Wall
2
2
2
2
2
2
2
cabinet is protected by not less
the 1/4" of flame retardant
material covered with not less
than No.28 MSG sheet metal,
0.015 inch stainless steel,
0.024 inch aluminum or
copper. (See Figure 1.) The
minimum horizontal distance(s)
from the side and back edge of
the unit to adjacent vertical
combustible walls are as
follows: Left side wall - 3
inches; right side wall - 3
inches, rear wall - 1 inch.
Cooktops installed over a CT130
oven require adequate air inlet to
the cabinet below. This is to
prevent simmer flame outage when
operating the oven. Provide
approximately 10 in.2 opening in
the toe kick area or other cabinet
area.
•Instructions are based on
Standard American cabinets
36" high x 24" deep.
Maximum depth of cabinets
installed above cooking surface of
the cooktop is 13 inches.
Maximum depth of drawer under
unit is 15 inches.
Page 3
Dimensions are to Combustible Materials
and are minimum requirements
! CAUTION:
◆
All measurements given have
to be precisely followed. If
nonstandard cabinets are
used care should be taken to
alter dimensions accordingly.
STEP TWO: OVERHEAD HOOD
•Thermador recommends use of a ducted hood over
this cooktop. For wall-mounted hood installations,
Thermador recommends that the hood should have
a certified rating of no less than 350 CFM on the
highest setting. The exhaust hood must be installed
according to instructions furnished with the hood.
Observe all local codes and ordinances governing residential cooking and ventilation requirements.
HOODS
WALL
ISLAND
STEP THREE: ELECTRICAL REQUIREMENTS & GROUNDING
THIS APPLIANCE MUST BE CONNECTED TO A RECEPTACLE ON A CIRCUIT RATED 120 VOLTS, AC 60HZ., 15 AMPERE
Recommended Grounding Method
Always disconnect electric supply cord from wall outlet before servicing
this appliance.
Observe all governing codes and ordinances when grounding. In the absence of these codes or ordinances observe National Electrical Code ANSI/
NFPA No. 70 Current Issue.
This appliance is factory equipped with a power supply cord with a threeprong grounding plug (with polarized parallel blades). IT MUST BE
PLUGGED INTO A MATING GROUNDING TYPE RECEPTACLE, CONNECTED TO A CORRECTLY POLARIZED 120 VOLT CIRCUIT. Improper
polarization will cause malfunction (such as continuous sparking of the
burner igniters) and may damage this appliance and could create a
condition of shock hazard at the igniter of each burner. If the circuit does
not have a grounding type receptacle, it is the responsibility and obligation
of the installer or user to have the existing receptacle changed to a properly grounded and polarized receptacle in accordance with all applicable
local codes and ordinances by a qualified electrician. In the absence of
local codes and ordinances, the receptacle replacement shall be in accordance with the National Electrical Code. THE THIRD GROUND PRONG
SHOULD NOT UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED.
See Fig. 2.
Alternate Grounding Method - See Fig. 3.
If installing a properly grounded wall receptacle is impossible at the time of
installation, consult your local electrical inspector for permission toconnect a temporary adapter (with polarized blades) which could be
plugged into your present 2-wire receptacle. This is not recommended.
If this is done, you must attach the lug and/or the green adapter wire to
the receptacle cover plate screw. Ground from it to a grounded metal cold
water pipe,* see Fig. 3. DO NOT GROUND TO A GAS SUPPLY PIPE.
You must permanently ground the adapter before connecting the appliance to the power supply.
CAUTION: Attaching the adapter ground wire to the wall receptacle
cover screw does not ground the appliance unless the cover screw is
grounded through the house wiring.
If there is any doubt as to whether the wall receptacle is properly
grounded, the customer should have it checked by a qualified electrician.
Cold water pipe must have metal continuity to the electrical ground and
not be interrupted by plastic, rubber or other electrically insulating
connectors (including water meter or pump) without adding a jumper wire
at these connections. See Fig. 4.
Fig. 2
Fig. 3
Ground
Wired
Fig. 4
Metal
Water
Pipe
Receptacle Box
Cover Plate
Three Prong Plug
Two Prong
Receptacle
Cover
Plate
➝
➝
Ground
Wire
➝
Three Prong
Adaptor
➝
Three
Prong
Plug
No. 4 Wire
➝
➝
➝
Clamp
Three Prong
Receptacle
➝
➝
Grounded Cold
Water Metal Pipe
Meter
➝
➝
➝
➝
➝
➝
Clamp
Page 4
STEP FOUR: PREPARE CABINET
1. See Cabinet Considerations
under
Step One: Before You Begin,
page 3.
2. Instructions are based on Standard American cabinets 36" high
x 24" deep.
If nonstandard cabinets are used care should be taken
to alter dimensions accordingly.
3.
All cutout dimensions given in
figure 5 have to be precisely followed.
4. Plan the installation of the unit so
that the power cord, gas shut-off
valve and gas pressure regulator
are accessible from the front of
cabinet. If a drawer is installed,
directly under the cooktop, its
depth should be no greater than
15 inches.
5. This unit has been Design Certified for installation in countertop
near adjacent walls and projecting surfaces constructed of combustible materials. The minimum
horizontal distance from the back
edge of the cooktop to adjacent
vertical combustible wall, and
minimum horizontal distance
from front edge of cooktop to front
side of countertop is 1 inch. The
minimum horizontal distance
from the sides of the cooktop to
the adjacent vertical combustible
walls are as follows: left and right
side walls is 3 inches and to the
rear wall is 1 inch.
Fig. 5
1/8" Min. Clearance
from Cooktop Edge
to Start of Radius
CABINET AND COUNTERTOP DIMENSIONS
1" Min. to Wall
"B"
"F"
1" Min.
3" Min. to Wall
21-3/4"
"E"
3" Deep
from Top
of Counter
3" Min. to Wall
3" Min. to Wall
COUNTERTOP CUT-OUT DIMENSIONS
COOKTOP
MODELS
GGS30,
GGN30,
SGS30 &
SGN30
GGS36/365,
GGN36/365,
SGS36G &
SGN36G
DIM.
REPLACEMENT
26-1/2" min.
E
29-7/8" max.
18-5/16" min.
F
20-15/16" max.
E
33" min.
35-1/8 max.
18-5/16" min.
F
20-15/16" max.
NEW
INSTALLATION
EXCEPT
OVER CT130
OVEN
27"
19"
33-1/2"
19"
NEW*
INSTALLATION OVER
CT130
20"
35"
20"
OVEN
SOLID**
SURFACE
MATERIAL
29-3/4"29-3/4"
20"
35"
20"
COOKTOP
WIDTH “B”
30-3/4"
36"
* Cooktops installed over CT130 ovens require larger cutouts (see Fig. 5).
™
** Solid surfacing material countertops such as Surell
and Corian® require
larger cutouts and special installation specified in cooktop securement
section, (see Step 5).
STEP FIVE: INSTALL THE COOKTOP
APPLY TAPE AND SECURE
COOKTOP TO COUNTER
A foam tape is provided to seal
the cooktop edges to the countertop, shown in Fig. 6. Apply tape to
the cooktop glass on the perimeter
prior to installing the cooktop.
Position the tape to the glass on
Models GGS & GGN and to the
burner box on Models SGS & SGN
(as shown).
The cooktop may be secured to
the countertop using hold-down
brackets provided. Attach
clamps to the burner box using
washer andscrews provided prior
to inserting cooktop into the cutout. Insert cooktop into cutout.
Adjust hold down brackets to
desired position and tighten
screws to burner box. Insert
clamping screw into clamp and
secure cooktop to counter top,
see Fig. 6 on Page 6.
Counter tops made from SOLID SURFACING MATERIALS, such as Surell™
and Corian®, require special cut-out
preparation and installation procedures.
Follow the manufacturers guidelines in
preparing the cut-out to the dimensions
noted in Fig. 5, above.
Continued on Page 6
Page 5
STEP FIVE: INSTALL THE COOKTOP
Continued from Page 5
Install the cooktops as follows:
a) Apply heat reflective tape (such
as Scotch® Aluminum Foil Tape
#425 or #427) around the cutout so that it folds over on the top
and sides. DO NOT WRAP THE
TAPE UNDERNEATH THE COOKTOP. Be sure the tape extends
beyond the outermost flange of
the cooktop. All corners should
also be covered with tape, see
Fig. 7.
b) Attach clamps to the burner box
using washer and screw provided,
see Fig. 6.
c)Center cooktop in center of cut-
out to insure adequate clearance
between the burner box and
counter top edge. (A light pencil
mark along center of front edge
and side edge of cooktop and
counter will aid positioning the
cooktop in the center).
Fig. 6
Fig. 7
ATTACHING HOLD DOWN BRACKETS & FOAM
Burner Box
Adjusting
Screw
TAPE INSTALLATION
Clamp
GGS & GGN
Foam Tape (seal)
GLASS TOP
Wooden Block
(to be used with solid
surfacing material, i.e.
Surell and Corian)
Burner Box
Adjusting
Screw
Clamp
COUNTER CUTOUT -
Shows location of Aluminum
Reflective Tape
GG
Foam Tape (seal)
Adjusting
SGS & SGN
Screw
PORCELAIN TOP
Wooden Block
(to be used with solid
surfacing material, i.e.
Surell and Corian)
Burner Box
Clamp
CAUTION
Avoid scratching or chipping the
edges of the cut-out with cooktop
burner box.
d) Adjust and tighten clamps to the
burner box. Insert clamping
screw into clamp.
CAUTION
Insert a wooden block between the
end of the screw and the bottom of
the SOLID SURFACING MATERIAL
countertop. Do not overtighten
clamping screw, see Fig. 6.
e) Trim excess aluminum tape around
cooktop flange.
STEP SIX: POWER SUPPLY HOOKUP
GAS CONNECTION
The gas inlet to the unit is located at the right rear of rough-in box. (See
Fig. 8). After installing a gas shut-off valve in an easily accessible location
under the unit (see Fig. 9), install the gas pressure regulator (supplied) to
manifold pipe using pipe dope on threads of manifold pipe. To prevent
possible damage to the gas pressure regulator, install it after the rough-in
box is in its permanent position. Proceed with gas connection.
Connect the gas supply line to the unit pressure regulator using a
1/2" flex gas line connector between wall shut-off valve and pressure
For Massachusetts Installations:
1. Shut-off valve must be a “T” handle gas cock.
2. Flexible gas connector must not be longer than 36 inches.
3. Not approved for installation in a bedroom or a bathroom
unless unit is direct vent.
Page 6
!
regulator (see complete procedure
at Fig. 9).
Always use pipe dope on the pipe
threads and be careful not to apply
excessive pressure when tightening
the fittings.
STEP SIX: POWER SUPPLY HOOKUP
CAUTION:
Do not attempt any adjustment of
the pressure regulator, except conversion to propane.
Turn on gas and check supply line
connections for leaks using a soap
solution. Do not use a flame of
any sort.
NATURAL GAS
The cooktop is shipped from the factory for use with natural gas only.
The gas supply to the appliance regulator must be a minimum of 6.0"
water column.
PROPANE GAS
!
The cooktop must be converted for
use with propane gas use Kit #
NLPKIT5 P/N 35-00-622 which contains new burner jets (orfices) and
instruction for adjusting valves and
regulator.
CAUTION:
When connecting unit to propane
gas make certain the propane gas
tank is equipped with its own high
pressure regulator in addition to the
pressure regulator supplied with the
appliance. The maximum gas pressure to the appliance regulator is not
to exceed 14.0" water column from
the propane gas tank.
Important Notes for Gas
Units:
(a) The appliance and its indi-
vidual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess
of 1/2 psig (3.5 kPa).
(b) The appliance must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve during
any pressure testing of the gas
supply piping system at test
pressures equal to or less than
1/2 psig (3.5 kPa).
Important Electrical
Connection Instructions
This appliance is now ready for connection to the properly grounded and
polarized three-prong wall receptacle
located within reach of 6-foot supply
cord. The circuit required is 15 Amp,
120Volt, 60 Hz. Before connecting
supply cord to wall receptacle make
certain that wall shut-off valve and
all burner controls are in “OFF” position.
Operation of electric igniters should
be checked after unit and gas supply
have been carefully checked for leaks
and unit is connected to electric
power.
Fig. 8
Table 1
Opening for Gas
Connection &
Electrical Cord
2"
C
L of Cutout
11-5/8" for GGS30, GGN30,
SGS30 & SGN30
14-7/8" for GGS36/365,
GGN36/365, SGS36G &
SGN36G
Fig. 9
Pressure
Regulator
Direction of
Gas Flow
Rough-In Box
Pipe Threads
Flex Gas Line
Shows
Gas Shut-Off Valve
Gas Stubout
Cabinet Floor
MODEL VOLTS CIRCUIT REQUIRED HZ.GASMANIFOLD PRESSURE
Thermador is a leading manufacturer of Convection Micro Thermal Ovens, Convection Thermal Ovens, Thermal Electric Ovens,
Warming Drawers, Free-Standing and Slide-In Ranges, Steel Gas ExtraLow® Cooktops, Steel Gas Cooktops, Glass Gas ExtraLow
Cooktops, Glass Gas Cooktops, Glass Ceramic Gas Cooktops, Glass Ceramic Dual-Fuel Cooktops, Glass Ceramic All-Radiant
Cooktops, Glass Ceramic Halogen Cooktops, Electric Cooktops, Professional® All-Gas Ranges and Cooktops, Professional
Dual-Fuel Ranges, Cook'n'Vent® Downdraft Ventilation System, Hoods, Ventilators, Housings, Dishwashers and Char-Glo® Outdoor
Barbecues. Specifications are for planning purposes only. Refer to installation instructions and consult your countertop
supplier prior to making counter opening. Consult with a heating and ventilating engineer for your specific ventilation requirements.
For the most detailed information, refer to installation instructions accompanying product or write Thermador indicating the
model number.
Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada.
Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your
local Canadian distributor or dealer. Thermador, 5551 McFadden Avenue, Huntington Beach, CA 92649.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328