Q: Do you know what type of breaker is required for the CIT151DS model of the cooker or what is the circuit breaker rating?
A: The model requirements a circuit breaker rating of either 20 Amps for 240 Volt and 208 Volt.
Q: Can you tell me what the dimension of the cooktop in CIT151DS model is?
A: The unit has an 85 mm height or 3 1/3 inches which makes it 135 mm or 5 1/3 inches with the heat shield installed.
Q: Do heat shields have to be installed?
A: Indeed, it is imperative to install heat shields to avert the chances of overheating and allowing the warm air around the cooktop to cool down and circulate.
Q: How much space would be needed from the cooktop to the cabinets or any other load-bearing shelves above it?
A: In an ideal setting, a safe distance of not less than 30” (762mm) should be maintained, although this can be brought down 24” (610mm) if substantial flame-retardant shielding is properly installed and located.
Q: What tools are needed to install the cooktop?
A: A range of tools is required to perform the installation including but not limited to a jigsaw, tape measure, drill with a quarter inch bit and a Philips head screwdriver.