Thermaco W-200-IS Installation Manual

Installation & Operation Instructions
1
2
3
4
17.85 in
453.4 mm
25.85 in
656.6 mm
For Big Dipper 40000 Series
Internal Strainer (IS) Units
(Including 230 VAC Units)
Part# MNL-ISPS40000
®
Copyright ©2016 Big Dipper® Thermaco, Inc. • P.O. Box 2548 • Asheboro, NC 27204
Toll Free: (800) 633-4204 • V: (336) 629-4651 • F: (336) 626-5739
AEA
* Please consult Thermaco, Inc. for specic models
tested, certied and/or listed by these organizations.
info@thermaco.com • www.big-dipper.com
40000 Series
Table of Contents
Table of Contents
IS System Overview 3
IS System Maintenance 4
IS Digital Control Operation 5
IS System Troubleshooting 7
How To Reverse IS System Operation 8
Plumbing Installation 9
Vented Flow Control Installation 11
Electrical Installation 12
IS System Wiring Diagram 13
IS Component Identication 14
IS Replacement Parts 16
Limited Warranty 17
©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-ISPS40000 2
40000 Series
Big Dipper® Internal Strainer (IS)
System Overview
Big Dipper Internal Strainer System Overview
The Thermaco, Inc. Big Dipper® Automatic Grease and Oils Removal System removes free-oating
grease & oils from kitchen drain water ows. As most food service facility managers already know, grease buildup within a building’s plumbing drainage system is a major cause of prob­lems due to drain line blockages. These problems jeopardize normal operations as well as create health and safety hazards within the facility itself.
The proper installation of a Big Dipper System can reduce or eliminate grease problems. Use of the Big Dipper assures minimization and/or elimination of costly sewer surcharges and nes through efcient separation and removal of free-oating grease & oils. In addition, the Big Dipper also helps reduce or eliminate pumping and disposal costs associated with conventional grease separators or intercep­tors. The recovered grease & oils are substantially water-free and are suitable for recycling by local rendering and/or biodiesel companies.
The Big Dipper system is an automatic, self-cleaning device. As greasy kitchen efuent drains from kitchen xtures, the unit contains the grease & oils. These separate from the efuent and rise to the surface of the separator tank. The unit automatically skims the contained grease & oils and transfers the grease & oils to a collection container. A digital control maintains the self cleaning operation, activating the skimming wheel periodically based on the setting chosen. Only the “cleaned” water exits the unit and ows into the facility drain lines. The Big Dipper IS automatic systems operate most efciently when servicing single xtures such as a 1 to 3-compartment sink or a pre-rinse station.
The Big Dipper system’s compact footprint allows installation directly at the source where grease problems originate. The system design also allows easy maintenance and operation requiring only a minimal amount of daily and weekly maintenance to maintain peak operating performance.
The Big Dipper system design allows for maximum installation exibility. Reversing the system op­eration is a simple as rotating the cover assembly of the unit.
Hydromechanical grease interceptors*, grease separators, automatic recovery units, grease removal devices and other similar plumbing devices receiving kitchen ows from sinks, oor drains, woks and other food bearing sources may generate odors. There are many factors inuencing odor evolu­tion and dissemination. These include room ventilation, kitchen menu, ambient temperatures, ware washing practices, grease/oil input, daily input uid volume, sanitizers, installation plumbing design and product maintenance/upkeep. Odors are usually prevented by good area ventilation, frequent uid inputs, good product maintenance practices and proper product installation. Additional steps, including aeration, chlorination, improved area ventilation and additional maintenance control, may be needed at some sites.
*Devices formerly referred to as grease traps are now called hydromechanical grease interceptors.
©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-ISPS40000 3
40000 Series
Big Dipper® Internal Strainer (IS)
System Maintenance
Big Dipper® Internal Strainer (IS) System Maintenance
*CAUTION! DISCONNECT POWER TO UNIT BEFORE CLEANING
to prevent damage to the unit and personal injury
*NOTE: Before energizing unit after cleaning, ll tank with water
to protect wipers and heater from damage
Daily Maintenance:
(A) Empty the clear plastic grease/oils collection container (located beside the unit) prior to its be­coming full once each day. The Big Dipper recovers grease and oil virtually water-free so that they can be recycled. The collector container should be washed periodically so as to maintain the easy viewing translucent characteristic of the collector.
(B) The internal strainer basket should be removed and emptied into a garbage container by shaking briskly. Wash the inside and outside surfaces of the strainer after emptying.
Weekly Maintenance:
(A) Check the collection trough and the wiper blades for any solids build-up. Wipe off any accumulated deposits and assure that the wiper blades are clipped in place properly.
(B) Press the Start button (on the bottom of the user interface) momentarily to ensure that the motor and skimming wheel are still operating correctly.
(C) Check the thickness of the grease layer at the top of the unit. There should be no appreciable amount of grease or oil left in the tank immediately after the daily automatic skimming cycle. If there is more than a 1/2” (13 mm) thick layer of grease after the skimming cycle, this indicates a need to increase the skimming time. Increase the digital control settings accordingly until a clean unit ap­pearance is obtained after the automatic skimming cycle. A simple guide is to change to the next higher setting (Light [I] to Moderate [II] or Moderate [II] to Heavy [III]) and run for a period of time until enough grease is being skimmed from the tank.
Quarterly Maintenance:
(A) The internal strainer basket in the unit is designed to remove incidental solids from kitchen drain ows. Over a period of time, sediment consisting of very ne particles may begin to accumulate on the bottom of the unit. If this build-up is allowed to continue, it may eventually block the outlet bafe. To prevent this from occurring, remove the lid and stir the bottom of the unit with a long handled spatula while water is owing to ush out the sediment. Occasionally drain and clean the unit thoroughly. Properly used, a wet-vac may be appropriate for this purpose.
©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-ISPS40000 4
40000 Series
REVISIONS
ZONE REV DESCRIPTION DATE APPROVED
Big Dipper® IS System
Digital Control Operation
Digital Control Operation (Default Modes)
Timed Skimming Default
Through the “User Interface” three levels of skimming may be selected in the “default” mode. By selecting one of the skimming buttons – I, II, or III - the skimming cycle (see table below) is activated. The LED associated with the selected button is illuminated
continuously as an indicator of the
selected skim cycle and as a “power on” indicator. If the skimming level is changed during an active skimming cycle, the next active skim cycle will be at the new setting (The LED associated with the newly selected level will change immediately). If the skimming cycle is changed between active skimming cycles the next skim cycle will be at the new level.
Motor Exercising
For all default mode skimming levels, the motor will be energized for 30 seconds every 9.5 hours. Only the motor will be energized (no heater operation) at these exercising times.
Start Button Operation
Any time the start button is depressed the “time between skims” the digital control goes to its maximum time and operation begins for the selected skim level. After this skimming cycle the normal time delay to the next skim cycle is used (skim cycle resets when the start button is depressed).
Light Setting:
Recommended for
Light Grease Output
(Small Cafes, Coffee/
Ice Cream shops***)
Moderate Setting:
Recommended for
Moderate Grease Output
(Quick and Full-Service
restaurants***)
Recommended for
Heavy Grease Output
(Steakhouses, Buffets,
producing sites***)
Start Button: Press
to begin a cycle early
or to test operation..
Heavy Setting:
Heavy Grease
Heater Operation
The heater operates under Thermistor control any time the skimmer motor is energized and anytime the liquid temperature drops to 40º F to prevent liquid from freezing. Contact Thermaco for programming alternative heater settings.
Default Modes - Normal Operation*
Button Selected Skim Time Delay Between Skims**
Light (I) 15 Minutes 76 Hours
Moderate (II) 30 Minutes 19 Hours
Heavy (III) 60 Minutes 19 Hours
* For Extreme Conditions see next page. ** Delay between Skims is the time from the start of the 1st skim to the start of the next skim. *** Only examples, actual mode needed will vary depending upon menu, warewashing procedures, etc.
©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-ISPS40000 5
40000 Series
REVISIONS
ZONE REV DESCRIPTION DATE APPROVED
Big Dipper® IS System
Digital Control Operation
Digital Control Operation (Extreme Modes)
Extreme Operation
For Food Service Operations which produce more grease and need additional run-time, the 40000 Series Big Dipper provides additional modes for extreme operation. In order to access these modes:
1. Remove power from CLA by unplugging unit or lifting it to disengage the safety switch (found on underside of the back of assembly).
2. Reapply power while holding down the Heavy Mode (III) Button.
3. The button (III) will blink temporarily, indicating which operation level has been selected.
4. Select desired mode at skim times/frequencies listed below.
Extreme Modes
Button Selected Skim Time Delay Between Skims*
Light (I) 90 Minutes 19 Hours
Moderate (II) 120 Minutes 19 Hours
Heavy (III) 120 Minutes 9.5 Hours
* Delay between Skims is the time from the start of the 1st skim to the start of the next skim.
To return to Default Modes, follow the instructions above, but press the Light Mode (I) Button instead of the Heavy Mode (III) Button. The Light Mode (I) Button will temporarily blink to indicate this operational level has been selected.
Hold down Light
Mode (I) Button
when connecting
power to unit to
switch back to
default modes.
Hold down Heavy
Mode (III) Button
when connecting
power to unit to
switch to extreme
modes.
©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651
MNL-ISPS40000 6