Trapzilla® Supercapacity Grease Traps
VFCA Vented Flow Control
Installation Instructions
Sometimes space restrictions require the installation of Trapzilla units in basement locations where signicant
head pressure becomes a factor. The Trapzilla® VFCA Vented Flow Control module provides an option for use
with installations where a signicant amount of head pressure is present (greater than 6 ft./1.95 m) or where applicable regulations require vented ow controls. A Vented Flow Control helps reduce problems associated with
high head pressure and helps slow the drainwater ow down. The VFCA kit contains an appropriate tting and
ow control orice.
Flow Control Vent/Air Intake
(Note: Flow Control Vent may be independent direct connect
to atmosphere or code-approved air admittance valve. To
be installed above sink ood rim.)
NEVER CONNECT TO FACILITY VENT
Drainage Piping
from Kitchen
Outlet Vent
(Note: Vent may be facility vent connection or
code-approved air admittance valve)
Installations where head
height is greater than 6 feet
(1.95 m)
Trapzilla
VFCA-35 Vented Flow Control for TZ-160
VFCA-75 Vented Flow Control
- for both TZ-400 & TSS-70
VFCA-125 Vented Flow Control
- for both TZ-600 & TSS-95
* Installation in high head height
locations requires removal of the
LHFC Flow Control provided with
your Trapzilla unit should NOT be
install when using a Vented Flow
Control Assembly VFCA.
Optional P-Trap
NOTE: Drawing for reference only. Equipment must be installed in
compliance with all applicable laws, regulations and codes, including plumbing codes. Installation should be performed by a qualied
plumber.