The Big Dipper® HAG Horizontal Air Gap Assembly Kit offers a simple yet effective
method for providing an air gap for meeting health department or plumbing code require­ments. Among the many different methods of creating an air gap to protect against cross­contamination, the most popular is an air gap directly between the sink discharge and the outow piping. This means that in the event of a backup, efuent will spill out of this gap under the sink discharge and directly onto the oor without any danger of cross-contamina­tion. The optional eld-installable HAG-BA- 1 Solids Strainer Baskets collect incidental solids from the drain ow.
How Does the HAG Air Gap Assembly Work?
Drain
Sink Drain Sink Drain Sink Drain
Flow
Control
2” Gap Min. (50 mm)
Flow
Control
Air Gap Drain Trough
2” Gap Min.
(50 mm)
Flow
Control
Flow
Support
Leg
*Optional HAG-BA-1
Solids Strainer Baskets
Not Shown
As the sink drains, efuent ows into the all stainless steel construction HAG Air Gap. The ow is slowed down by ow controls (provided) attached at the end of each drain stem. There is a 2” (50 mm) or greater gap between the bottom of the drain tailpiece and the drainage pip­ing. In the event of a blockage downstream of the sink, efuent ows out of this 2” (50 mm) gap onto the kitchen oor preventing any cross-contamination between the sinks or contami­nation from efuent. The HAG Air Gap may also be plumbed through a Big Dipper® Auto­matic Grease & Oils Removal Unit. Incidental solids in the ow may be strained and collected using the optional, eld-installable HAG-BA-1 Solids Strainer Baskets. The HAG is mounted to the oor using threaded rod support legs and feet (supplied). A Bracket that mounts the HAG assembly to the wall is also provided.
Tailpiece
Support
Leg
Big Dipper®
Unit
©2011 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
6/11
646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 • North America: (800) 633-4204
E-mail: info@thermaco.com • Online: www.big-dipper.com
1
®
HAG-2 Horizontal Air Gap Trough Component
Options
2” (50 mm) Pipe Outlet
(10.1 cm)
4” (10.2 cm)
3” (7.6 cm)
6” (15.2 cm)
Outlet View
Threaded Rod Support Leg
2” (50 mm) Pipe Outlet
Support Foot &
Side View
1.5”
(3.81 cm)
* The HAG-2 Air Gap is shipped in 72” (182.9 cm) lengths. It is eld-trimmed to t the appli­cation. It is recommended 8” (20.3 cm) be left behind the drain valve that is furthest from the Big Dipper® unit. The threaded rod supports & wall mount brackets must also be trimmed to t the sink installation. A 1/4” drop should be used for every 1’ of run (2 cm per meter).
HAG-3 Horizontal Air Gap Trough Component
4”
3” (150 mm) Pipe Outlet
3” (7.6 cm)
6” (15.2 cm)
Outlet View
3” (150 mm) Pipe Outlet
Support Foot &
Threaded Rod Support Leg
Side View
4” (10.2 cm)
1.5”
(3.81 cm)
* The HAG-3 Air Gap is shipped in 72” (182.9 cm) lengths. It is eld-trimmed to t the appli­cation. It is recommended 8” (20.3 cm) be left behind the drain valve that is furthest from the Big Dipper® unit. The threaded rod supports & wall mount bracket must also be trimmed to t the sink installation. A 1/4” drop should be used for every 1’ of run (2 cm per meter).
©2011 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice