Field of application
Variable isolating transformers are portable devices which are arranged in 19” housings. These variable and low- resistance a.c. voltage sources can be used in all fields, especially in workshops, laboratories, test stands and service shops. Due to the galvanic separation between the primary and the secondary by means of a test voltage of 3,5 kV and the construction according to the protective system II these transformers are especially suitable for use electric workshops, where they are employed for protective isolation of electric or electronic devices which are in need of repair. They are useable only in dry rooms.
The output voltage ca be easily adjusted between 1 V and 250 V by means of the adjustable transformer. In continuous operation, the transformer can be subjected to maximum current loading throughout the whole adjusting range.
The most apparent advantage of such a voltage control are the maintenance of the output voltage curve, the nealy loss-free voltage or adaption of current and the relatively low internal resistance.
Operating instructions
The transformers can be used either individually or in combination with other devices in measuring places or laboratories. Take care to ensure that they are vented through the ventilating ducts available. The ambirent temperature should not increase over 40
o
C.
Variable isolating transformer LTS
voltmeter
mains signal lamp
mains switch
ampmeter
socket
secondary fuse
adjusting knob of output voltage