Backplate wiring: Example (Volt Free)
3,
To appliance
Wiring diagram (Volt Free)
5 4 3 2 1 E
Live out to
appliance
Live In to
timer
12345
230V AC Supply
M
~
LN
230V AC
mains supply
Power / Set-up
Button
WiFi Signal
Indicator
Specification
PROG CAPACITY:
COMMS:
COUNTDOWN:
RANDOM:
REPEAT:
DIMENSIONS:
WEIGHT:
POWER:
RESISTIVE LOAD:
INDUCTIVE LOAD:
TEMP RATING:
ACCURACY:
MIN. SWITCHING:
OVERRIDE:
Class II control / Protection class IP20
Complies with European Norm
EN 61058-1:2002+A2:2008
Switches for Appliances: General
Requirements,and European Directives:
LVD; EMC; RoHS; RED
www.tfc-group.co.uk
TFC Group LLP Tonbridge TN9 1TB
WiFi ISM 2.4GHz; WLAN 802.11 b/g/n
20 On/Off Programmes
Countdown On or Off
Output switches randomly during set
period.
A repeating cycle that can be set
between the ON and OFF times.
92 x 92 x 60
170g
1vA @ 230V 50Hz
16 Amperes
4 Amperes (cos Ø 0.6)
-10T55
Internet Synchronised
1 Minute
On / Timed / Off
WiFi Socket Box
Time Switch
For general purpose use
Installation instructions
OP-SBWF01 WiFI Socket Box Timer
Min switching 1 Minute
1. Installation procedure
2. Backplate wiring Example
3. Backplate wiring Example
4. Specification
OP-SBWF01 Installation InstructionsOP-SBWF01 Installation Instructions
(230V AC 50-60Hz)
(Volt Free)

Please read the instructions fully
before attempting installation.
IMPORTANT
Installation must be carried out in
accordance with the current edition of
the I.E.E. Wiring Regulations. It is
recommended that installation is
undertaken only by a qualified
electrician.
● Timer must not be mounted on a
flammable surface.
● Ensure that the timer does not come
into contact with any combustible
materials such as towels or bedding.
● Ensure at least a 300 mm air space is
allowed around the timer.
● The timer should not be mounted on an
unearthed metal or metallised surface.
● If the timer is to be connected to an
appliance that is required to be earthed the
supply earthing conductor and the
appliance earthing conductor should be
terminated together in the earth terminal
provided within the timer.
1. Installation procedure
1. Switch the supply off at the mains. Means
of disconnection from the supply having at
least 3 mm contact separation in all poles
must be incorporated in the fixed wiring
mains supply.
2. Unscrew the two screws located top right
and bottom left of front module cover;
remove cover and gently pull module from
backplate. Do not put undue stress on, ‘or’
interfere with fixed connecting wires. Bare
wires back for 6 mm (1/4 inch) maximum;
insert into terminals and secure with the
screws, in accordance with circuit diagram
label beneath terminals.
Note: Do not connect unprepared
stranded wires. Use ferrules supplied
to crimp stranded wire terminations.
3. Fix backplate to socket box.
4. Connect wiring in accordance with wiring
diagram.
5. Fit cover over module and reassemble to
backplate. Ensuring fixed blue wires are
stowed neatly without being trapped.
6. Re-fit and tighten two screws.
7. Switch on mains.
Backplate wiring: Example (230V AC 50-60Hz)
2.
Wiring diagram (230V AC 50-60Hz)
5 4 3 2 1 E
L N L N
to appliance mains supply
OP-SBWF01 Installation Instructions
12345
M
~