TFA Dostmann DT-8862 Operating Manual

Page 1
Non-Contact Infrared Thermometers
Operating Manual
3 p
Page 2
TABLE OF CONTENTS
INTRODUCTION………………………………………3 FEATURES……………………………………………3 WIDERANGEAPPLICATION
………………………… 4
SAFETY
……………………………………………… 4
DISTANCE&SPOTSIZE
……………………………… 5
SPECIFICATIONS
…………………………………… 6
FRONTPANELDESCRIPTION
……………………… 8
INDICATOR
……………………………………………8
BUTTONS………………………………………………9 MEASURMENTOPERATION………………………… 10 BATTERYREPLACEMENT
…………………………… 13
NOTES
……………………………………………… 13
MAINTENANCE
…………………………………… 17
2
Page 3
INTRODUCTION
Thank you for purchase of the IR Thermometer. This is capable of non-contact (infrared) temperature measurements at the touch of a button. The built-in laser pointer increases target accuracy while the backlight LCD and handy push-buttons combine for conv enient, ergonomic operation. The Non-contact Infrared Thermometers can be used to measure the temperature of objects’ surface that is improper to be measured by traditional (contact) thermometer (such as moving object, the surface with electricity current or the objects which are uneasy to be touched.) Proper use and care of this meter will provide years of reliable service.
FEATURES:
z Rapid detection function z Precise non-contact measurements z Dual laser sighting z Unique flat surface, modern housing d esign z Automatic Data Hold z / switch z Emissivity Digitally adjustable from 0.10 to 1.0
3
Page 4
z MAX temperature displays z Backlight LCD display z Automatic selection range and Display Resolution 0.1º
C(0.1ºF)
z Trigger lock z Set high and low alarms
WIDE RANGE APPLICATION:
Food preparation, Safety and Fire inspectors, Plastic molding, Asphalt, Marine and Screen printing, measure ink and Dryer temperature, HVAC/R, Diesel and Fleet maintenance.
SAFETY
z Use extreme caution when the laser beam is turned on. z Do not let the beam enter your eye, another person’s
eye or the eye of an animal.
z Be careful no to let the beam on a reflective surface
strike your eye.
z Do not allow the laser light beam impinge on any gas
which can explode.
4
Page 5
Distance & Spot Size
As the distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. The relationship between distance and spot size for each unit is listed below. The focal point for each unit is 914mm (36”). The spot sizes indicate 90% encircled energy.
D:S= 12:1
D
S
12in.1in @
6in.
0.5in @
25 mm @
300mm
150mm
12 .5mm @
1. SPECIFICATIONS
Temperature range D: S
-50 to 650 oC(-58 ~ 1202℉) 12:1
Display resolution 0.1 oC(0.1) <1000 1℉ >1000
Accuracy for targets:
5
Page 6
Assumes ambient operating temperature of 23 to 25 oC (73 to 77)
-50 ~ 20℃(-58 ~ 68℉) ±2.5℃(4.5℉) 20 ~300℃(68℉ ~572℉) ±1.0% ±1.0℃(1.8℉) 300 ~650℃(572℉ ~ 1202℉) ±1.5%
Repeatability
-50~20℃(-58~68℉) : ±1.3℃(2.3℉)
20~650℃(68~1202℉): ±0.5% or ±0.5℃(0.9℉)
Response time 150ms Spectral response 8~14um Emissivity Digitally adjustable from 0.10 to 1.0 Over range indication LCD will show “----” Polarity Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity Diode laser output <1mW,Wavelength 630~670nm, Class 2 laser product Operating temp. 0 to 50℃(32 to 122℉) Storage temp. –10 to 60 (14 to 140℉) Relative humidity 10%~90%RH operating, <80%RH storage Power supply 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
6
Page 7
Safety “ CE ” Comply with EMC
Note:
z Field of View: Make sure that the target is larger than
the unit’s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size.
2. FRONT PANEL DESCRIPTION
IR sensor LCD Display Laser
pointer beam
up button down button mode button Measurement Trigger Battery Cover Handle Grip
3. INDICATOR
Data hold Laser ” on” symbols Lock symbol
7
Page 8
High alarm and low alarm symbol / symbol
Low power symbols Emissivity symbol and value Temperature values for the MAX Symbols for MAX Current temperature value
4. Buttons
Up button (for EMS,HAL,LAL) Down button (for EMS,HAL,LAL) MODE button
(for cycling through the
mode loop)
Functional Design
1. the switches of C/F sat in a cell switching
2. In the measuring time up, down keys to adjust the
Emissivity.
3. IN the hold time, up keys to turn on or off the laser Down keys to turn on or off the backlight
4. To set value s for the High Alarm (HAL), Low Alarm (LAL) and Emissivity (EMS), press the MODE button until the
8
Page 9
appropriate code appears in the display, press the UP and down buttons to adjust the desired values.
MODE Button Function
Press the mode button also allows you to access the set state,Emissivity(EMS),Lo ck on/off,HAL on/off, HAL adjustment LOW on/off,LOW adjustment,Each time you press set you advance through the mode cycle. The diagram shows the sequence of functions in the mode cycle. EMS adjustment. The Emissivity(EMS) digitally
adjustable from 0.10 to 1.0,
LOCK on/off. The lock mode is particularly useful for continuous monitoring of temperatures. Press the up button or down button to
LOCK on/off
HAL on/off
HAL adjustment
LOW on/off
LOW adjustment
EMS adjustment
9
Page 10
turn on or off . Press the Measurement Trigger to confirm the lock measurement mode. The
IR
Thermometer
will continuously display the temperaure
until press again the Measurement Trigger.
In lock mode, press the up button or down button adjustable the Emissivity.HAL (LOW) on/off. Press the up button or down button to turn on or turn off. Press the Measurement Trigger to confirm the High(Low)alarm mode.Hal(LOW) adjustment. The high(Low) alarm adjustable form
-50 to 650 oC(-58 ~ 1202℉)
Switching C/F
Select the temperature units (oC or oF) using the oC/oF switch ( ① )
Max indicate the max record that displays between the pressing and releasing the "ON/OFF"
MEAS
rip and point it
button each time
UREMENT OPERATION
Hold the meter by its Handle G
10
Page 11
toward the surface to be measured.
ull and hold the Trigger to turn the meter on and begin testing. The display will light if the battery is good.
P
Replace the battery if the display does not
ress the DOWN button to
e trigger is
released.(Unless the unit is locked on)
Not
light.
Release the Trigger and the HOLD display icon will appear on the LCD indicating that the reading is being held. In HOLD status, press the UP button to turn on or off the laser. And p turn on or off the backlight. The meter will automatically power down after approximately 7 seconds after th
e: Measurement considerations
Holding the meter by its handle, point the IR Sensor toward the object whose temperature is to be measured. The meter automatically compensates for temperature deviations from ambient temperature. Keep in mind t hat it will take up to 30 minutes to adjust to wide ambient temperatures are to be measured followed by high temperature measurements, some time (several
11
Page 12
minutes) is required after the low (and before the high)
oling process, which must take
lace for the IR sensor.
5.
battery type 9V is
9-Volt battery and place the battery cover
back.
z
temperature measurements are made. This is a result of the co p
BATTERY REPLACEMENT
As battery power is not sufficient, LCD will display “ ” replacement with one new
required. Open battery cover, then take out the battery from instrument and replace with a new
6. NOTES:
How it Works
Infrared thermometers measure the surface
temperature of an object. The unit’s optics sense
emitted, reflected, and transmitted energy, which is
collected and focused onto a detector. The unit’s
12
Page 13
electronics translate the information into a temperature
reading, which is display on the unit. In units with a
is used for aiming purposes onl y.
z
re the target is at
e spot size.
z
a measured by the unit becomes
z
ith an up and down
ou locate hot spot.
z
es ( stainless steel, aluminum,
l measure the surface temperature of
laser, the laser
Field of V ie w
Make sure that the target is larger than the unit’s spot
size. The smaller the target, the closer you should be to
it. When accuracy is critical, make su
least twice as large as th
Distance & Spot Size
As the distance (D) from the object increases, the spot
size (S) of the are
larger. See: Fig: 1.
Locating a hot Spot
To find a hot spot aim the thermometer outside the area
of interest, then scan across w
motion until y
Reminders
Not recommended for use in measuring shiny or polished metal surfac etc.).See Emissivity The unit cannot measure through trans parent surfaces such as glass. It wil
13
Page 14
the glass instead.
Steam, dust, smoke, etc., Can prevent accurate
ng the unit’s optics.
z
ribe the
asure the temperature of the tape or
ainted surface.
measurement by obstructi
Emissivity
Emissivity is a term used to desc energy-emitting characteristics of materials. Most (90% of typical applications) organic materials and painted or oxidized surfaces hav e an emissivity of
0.95 (pre-set in the unit). Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cove the surface to be measured with masking tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath it. Me p
14
Page 15
Emissivity Va
Substance Substance
ivity
lues
Thermal emissivity
Thermal
emiss Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement o 0.80 0.96 Lather 0.75 t Sand 0.90 0.96 Charcoal
(powder) Earth 0.92 to 0.96 Lacquer o 0.95 0.80 t Water 0.92 to 0.96 r 0.97 Lacque
(matt) Ice 0.96 to 0.98 0.94 Rubber
(black) Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic o 0.94 0.94 0.90 t Paper 0.70 to Marble 0.94 m 0.81 Chromiu
oxides Plaster 0.80 to 0.90 0.78 Copper
oxides Mortar 0.89 to 0.91 Iron oxides o 0.82 0.78 t Brick 0.93 to 0.96 Textiles 0.90
15
Page 16
16
be carried out by qualified trained
. Do not use
ified parts.
7. MAINTENANCE
z Repairs or service are not covered in this manual and
should only technician.
z Periodically , wipe the body with a dry cloth
abrasives or solvents on this instrument.
z For service, use only manufacturer’s spec
Loading...