59mm
90mm
Instruction Manual
DOMINO
Remote Thermo-Hygrometer
for Smartphones
[For iPod, iPhone and iPad User] Nr. 30.5034
Main Unit
Location of control
1. Connect
2. Reset
3. Battery
compartment
Stand
Screws
distance
LED
30mm
Sensor ID label
1
Features
Thank you for choosing the DOMINO Remote ThermoHygrometer from TFA.
Before you start using it
• Please make sure to read the instruction manual
carefully.
• Following and respecting the instructions in your
manual will prevent damage to your instrument and
loss of your statutory rights arising from defects
2
due to incorrect use.
• We shall not be liable for any damage occurring as a
3
result of non-following of these instructions.
Likewise, we take no responsibility for any incorrect
readings and for any consequences which may
result from them.
• Please take particular note of the safety advice!
• Please keep this instruction manual for future
reference.
Field of operation and all the benefits of your new
instrument at a glance
• Temperature and humidity by means of a transmitter via
Bluetooth (BLE 4.0) with a range of up to 40 m
• Climate control for outside or inside
• Free app for easy operation
• Maximum and minimum values
Various international parameters for climate monitoring
such as WBGT
• Constant updating (while within transmission range)
• Simple link-up also possible with multiple devices
How to Install Sensor and RTH App
1. Install battery
1.1 Open the battery compartment.
1.2 Insert 2 x AAA batteries in polarity (+) and (-)
as indicated.
1.3 Close the battery compartment.
2. Install RTH App on your smartphone.
2.1 Access App Store and search for RTH .
2.2 Select and install RTH App on your mobile device.
Connect Your Sensor with RTH App
3. Connect sensor with RTH App
9:41 AM3G
3.1 RTH App will check your Bluetooth condition. If
Bluetooth is it will show pop up menu on display.
Press and then
turn the Bluetooth in your mobile.
Settings
Settings
OFF
3.2 Start RTH App in your mobile device.
9:41 AM3G
Connect Your Sensor with RTH App
3.3 For first connection
press and hold the
CONNECT button
on the sensor for 2
seconds. The red LED
on front side will light
up for 2 seconds and
flash until connection
succeeds.
3.4 During connection
“Connecting...” will
pop up on the display.
3.5 After a successful connection,
the pop up menu above will
show you the connected sensor ID (eg. sensor _AA302C.
(This code is printed on the
sensor)
3.6 If the sensor is not working
properly, press the RESET
button with a pointed object.
4. Repeat step 2-3 to connect
additional mobile devices
with the same sensor (The
sensor unit is able to support
multiple mobile devices).
Change Another Sensor with RTH App
5. Change another sensor
5.1 Press and hold the
CONNECT button
on the sensor for 2
seconds. The red LED
on front side will
light up for 2 seconds
and flash until
connection succeeds.
5.2 Open the RTH App. The
pop up menu above
appears. The user can
Yes
Yes
select confirm
another sensor or
to keep the existing
sensor connection.
5.3 During connection
“Connecting...” will pop
up on display.
5.4 After a successful connection,
the pop up menu above will
show you the connected sensor ID (eg. sensor _AA3031).
Make sure the ID belongs to
your desired sensor. If the
connection fails, the existing
No
No
sensor connection will be
kept.
5.5 After changing the sensor,
you may need to clear all
the recorded data. (See
No.10 Clear recorded
contents.)
Review DAILY / RECORDED Contents
6. Swipe the screen of Temperature and Humidity left and
right to browse the Maximum and Minimum records.
6.1 DAILY: Resets automatically at 0:00
Recorded data between 0:00 to the time
you view daily Max / Min
RECORDED: Recorded highest and lowest values
since the last manual reset
Humidity
Humidity
75%
CURRENT
CURRENT
MAXIMUM
MAXIMUM
RECORDED
RECORDED
MINIMUM
MINIMUM
MAXIMUM
MAXIMUM
80% 90%
DAILY
DAILY
MINIMUM
MINIMUM
20% 10%
Swipe the screen to the
left: the DAILY and
RECORDED Humidity
Max / Min. appears
36
Temperature
Temperature
27.0
CURRENT
CURRENT
MAXIMUM
MAXIMUM
30.0°C
°C
RECORDED
RECORDED
MINIMUM
MINIMUM
MAXIMUM
MAXIMUM
28.5°C
DAILY
DAILY
MINIMUM
MINIMUM
6.0°C 3.5°C
Swipe the screen to the
right: The DAILY and
RECORDED Temperature
Max / Min. appears
How to Personalize Home Page Screen
7. Personalize you home page
Press left corner icon to enter setting. User can turn
each index or .
If all indices are turned the home screen will show as
below.
9:41 AM3G
Remote
Therm Hygrometer
Temperature
Temperature
°C
27.0
CURRENT
CURRENT
RECORDED
DAILY
MAXIMUM
MAXIMUM
28.5°C 30.0°C
MINIMUM
MINIMUM
6.0°C 3.5°C
OFF
OFF
Remote
Therm Hygrometer
Temperature
Temperature
27.0
Humidity
Humidity
75%
9:41 AM3G
°C
9:41 AM3G
Remote
Therm Hygrometer
Temperature
Temperature
75%
CURRENT
CURRENT
DAILY
MAXIMUM
80% 90%
MINIMUM
20% 10%
RECORDED
MAXIMUM
MINIMUM
Index Setting
8. Index setting
OFF
8.1 User can turn or
OFF
to each index
by swiping the switch.
8.2 User can personalize
the sequence of
indices by pressing
the button.
8.3 After pressing
appears at each
index, except “Fahrenheit /
Celsius” and “Recorded
MAX / MIN” contents.
Index Setting Change The Temperature Reading
9. Change format reading
9.1 To change temperature
reading in Fahrenheit or
Celsius, press button
to enter setting.
9.2 At Fahrenheit / Celsius
row switch °C / °F to
your desired format.
36
8.4 Press and hold to
drag any index up or
down to personalize
your own sequence.
8.5 Press button and your
home screen will show the
indices in the sequence you
set.
29°C
708mm
59mm
90mm
Change The Temperature Reading
9.3
After setting the home screen
will show Fahrenheit or
Celsius for all temperature
and index readings.
Clear MAX / MIN Record
10. Clear recorded content
10.1 Go to Setting. Press
button on
“Recorded MAX / MIN”
content.
10.2 Pop up menu will
appear to ask your
double confirmation.
Select to clear
the record or
to cancel the action.
Clear MAX / MIN Record
10.3
9:41 AM
If is selected, the Temperature and Humidity section
of “Recorded MAX / MIN” will show - - .
Connection failed or disconnected
11. Connection failed or disconnected
If your devices do not receive any signal or are disconnected from the network over 3 minutes, the home screen will
turn into transparent. A pop up menu will remind the user
the bluetooth signal is lost or disconnected.
Low Battery / Out of Battery
12. Low battery detection
If the batteries of the RTH
transmitter are getting low,
above pop up menu will
appear on the screen.
If the RTH transmitter is out
of batteries, above pop up
menu will appear on the
screen.
reconnect.
WBGT Level
36
CAUTION
CAUTION
EXTREME
EXTREME
CAUTION
CAUTION
DANGER
DANGER
EXTREME
EXTREME
DANGER
DANGER
-Blank
-Caution
-Extreme Caution
-Danger
-Extreme Danger
29°C
WBGT (Wet Bulb Globe Temperature) is widely used, e.g.
for sports events to measure the potential heat stress to
prevent injuries replicated by temperature and humidity
correlation.
Humidex Level
36
29°C
Humidex is an index to describe how hot the weather feels
to the average person based on temperature and humidity
correlation.
COMFORTABLE
COMFORTABLE
SOME
SOME
DISCOMFORT
DISCOMFORT
GREAT
GREAT
DISCOMFORT
DISCOMFORT
DANGEROUS
DANGEROUS
-Blank
-Comfortable
-Some Discomfort
-Great Discomfort
-Dangerous
Heat Index Level
-Blank
-Comfort
COMFORT
COMFORT
-Caution
CAUTION
CAUTION
EXTREME
EXTREME
-Extreme Caution
CAUTION
CAUTION
-Danger
DANGER
DANGER
EXTREME
EXTREME
-Extreme Danger
DANGER
DANGER
36
29°C
Heat index is an index that combines air temperature and
relative humidity to determine the human perceived
equivalent temperature - how hot the subject feels.
Mold Index
-Blank
-Comfort
COMFORT
COMFORT
CAUTION
CAUTION
-Pre-Caution
-Caution
PRE-CAUTION
PRE-CAUTION
36
29°C
Flu Index
Flu Index
CAUTION
CAUTION
Mold index is an index to describe the condition that may
encourage mold growth based on temperature and humidity
correlation.
Flu Index
-Blank
COMFORT
COMFORT
PRE-CAUTION
36
PRE-CAUTION
CAUTION
CAUTION
29°C
Flu Index
Flu Index
CAUTION
CAUTION
Flu index is an index to describe the condition if it is likely to
transmit the common flu virus based on temperature and
humidity correlation.
-Comfort
-Pre-Caution
-Caution
Safety advice
For your safety:
• This product should only be used as described within these
instructions.
• Unauthorised repairs, modifications or changes to the product
are prohibited.
• This product is not be used for public information, it is only
intended for home use.
Caution!
Risk of injury:
• Keep this instrument and the batteries out of reach of children.
• Batteries must not be thrown into a fire, short-circuited, taken
apart or recharged. Risk of explosion!
• Batteries contain harmful acids. Low batteries should be
changed as soon as possible to prevent damage caused by
leaking. Never use a combination of old and new batteries
together, or batteries of different types.
• Wear chemical-resistant protective gloves and safety glasses
when handling leaking batteries.
• Remove the batteries if you do not use the product for a long
period of time.
Important information on product safety!
• Do not place your product near extreme temperatures, vibrations
or shocks.
• Protect it from moisture.
• The transmitter is protected against splash water, but is not
watertight. Choose a shady and dry position for the transmitter.
• Check the transmission of the signal from the outdoor trans-
mitter to the smartphone (transmission range 40 m free field).
• Within ferro-concrete rooms (basements, superstructures), the
received signal is naturally weakened.
• If necessary choose another position for the transmitter.
• Clean it with a soft damp cloth. Do not use solvents or scouring
agents.
Waste disposal:
Never dispose of empty batteries and rechargeable
batteries in household waste.
As a consumer, you are legally required to take them
to your retail store or to an appropriate collection site
depending on national or local regulations in order to
protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the EU
Waste Electrical and Electronic Equipment Directive
(WEEE).
Please do not dispose of this instrument in household
waste. The user is obligated to take end-of-life devices
to a designated collection point for the disposal of
electrical and electronic equipment, in order to ensure
environmentally-compatible disposal.
Declaration of Conformity
Herewith we declare, that this wireless transmission device does
comply with the essentials requirements of R&TTE Directive
1999/5/EC.
A copy of the signed and dated Declaration of Conformity is
available on request via info@tfa-dostmann.de.
TFA Dostmann GmbH & Co. KG
Zum Ottersberg 12, D-97877 Wertheim
No part of this manual may be reproduced without written consent
of TFA Dostmann. The technical data are correct at the time of
going to print and may change without prior notice.
The product manual in all available languages and the latest
technical data and information can be found by entering your
product number on our homepage
www.tfa-dostmann.de 02/14
RoHS
708mm