TFA Dostmann 30.5034 Instruction Manual

59mm
AA302C
90mm
Instruction Manual
DOMINO
Remote Thermo-Hygrometer for Smartphones
[For iPod, iPhone and iPad User] Nr. 30.5034
Main Unit
1. Connect
2. Reset
3. Battery compartment
Stand
Screws distance
LED
30mm
Sensor ID label
1
Features
Thank you for choosing the DOMINO Remote Thermo­Hygrometer from TFA.
Before you start using it
Please make sure to read the instruction manual carefully.
Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects
2
due to incorrect use.
We shall not be liable for any damage occurring as a
3
result of non-following of these instructions. Likewise, we take no responsibility for any incorrect readings and for any consequences which may result from them.
Please take particular note of the safety advice!
Please keep this instruction manual for future
reference.
Field of operation and all the benefits of your new instrument at a glance
Temperature and humidity by means of a transmitter via Bluetooth (BLE 4.0) with a range of up to 40 m
Climate control for outside or inside
Free app for easy operation
Maximum and minimum values
Various international parameters for climate monitoring
such as WBGT
Constant updating (while within transmission range)
Simple link-up also possible with multiple devices
How to Install Sensor and RTH App
1. Install battery
1.1 Open the battery compartment.
1.2 Insert 2 x AAA batteries in polarity (+) and (-) as indicated.
1.3 Close the battery compartment.
2. Install RTH App on your smartphone.
2.1 Access App Store and search for RTH .
2.2 Select and install RTH App on your mobile device.
Connect Your Sensor with RTH App
3. Connect sensor with RTH App
9:41 AM3G
3.1 RTH App will check your Bluetooth condition. If Bluetooth is it will show pop up menu on display. Press and then turn the Bluetooth in your mobile.
Settings
Settings
OFF
3.2 Start RTH App in your mobile device.
9:41 AM3G
Connect Your Sensor with RTH App
3.3 For first connection press and hold the CONNECT button on the sensor for 2 seconds. The red LED on front side will light up for 2 seconds and flash until connection succeeds.
3.4 During connection “Connecting...” will pop up on the display.
3.5 After a successful connection, the pop up menu above will show you the connected sen­sor ID (eg. sensor _AA302C. (This code is printed on the sensor)
3.6 If the sensor is not working
properly, press the RESET button with a pointed object.
4. Repeat step 2-3 to connect
additional mobile devices with the same sensor (The sensor unit is able to support multiple mobile devices).
Change Another Sensor with RTH App
5. Change another sensor
5.1 Press and hold the CONNECT button on the sensor for 2 seconds. The red LED on front side will light up for 2 seconds and flash until connection succeeds.
5.2 Open the RTH App. The pop up menu above appears. The user can
Yes
Yes
select confirm another sensor or to keep the existing sensor connection.
5.3 During connection
“Connecting...” will pop up on display.
5.4 After a successful connection, the pop up menu above will show you the connected sen­sor ID (eg. sensor _AA3031). Make sure the ID belongs to your desired sensor. If the connection fails, the existing
No
No
sensor connection will be kept.
5.5 After changing the sensor,
you may need to clear all the recorded data. (See No.10 Clear recorded contents.)
Review DAILY / RECORDED Contents
6. Swipe the screen of Temperature and Humidity left and right to browse the Maximum and Minimum records.
6.1 DAILY: Resets automatically at 0:00 Recorded data between 0:00 to the time you view daily Max / Min RECORDED: Recorded highest and lowest values since the last manual reset
Humidity
Humidity
75%
CURRENT
CURRENT
MAXIMUM
MAXIMUM
RECORDED
RECORDED
MINIMUM
MINIMUM
MAXIMUM
MAXIMUM
80% 90%
DAILY
DAILY
MINIMUM
MINIMUM
20% 10%
Swipe the screen to the left: the DAILY and RECORDED Humidity Max / Min. appears
36
Temperature
Temperature
27.0
CURRENT
CURRENT
MAXIMUM
MAXIMUM
30.0°C
°C
RECORDED
RECORDED
MINIMUM
MINIMUM
MAXIMUM
MAXIMUM
28.5°C
DAILY
DAILY
MINIMUM
MINIMUM
6.0°C 3.5°C
Swipe the screen to the right: The DAILY and RECORDED Temperature Max / Min. appears
How to Personalize Home Page Screen
7. Personalize you home page
Press left corner icon to enter setting. User can turn each index or .
If all indices are turned the home screen will show as below.
9:41 AM3G
Remote
Therm Hygrometer
Temperature
Temperature
°C
27.0
CURRENT
CURRENT
RECORDED
DAILY
MAXIMUM
MAXIMUM
28.5°C 30.0°C
MINIMUM
MINIMUM
6.0°C 3.5°C
OFF
OFF
Remote
Therm Hygrometer
Temperature
Temperature
27.0
Humidity
Humidity
75%
9:41 AM3G
°C
9:41 AM3G
Remote
Therm Hygrometer
Temperature
Temperature
75%
CURRENT
CURRENT
DAILY
MAXIMUM
80% 90%
MINIMUM
20% 10%
RECORDED
MAXIMUM
MINIMUM
Index Setting
8. Index setting
OFF
8.1 User can turn or
OFF
to each index by swiping the switch.
8.2 User can personalize the sequence of indices by pressing the button.
8.3 After pressing appears at each index, except “Fahrenheit / Celsius” and “Recorded MAX / MIN” contents.
Index Setting Change The Temperature Reading
9. Change format reading
9.1 To change temperature reading in Fahrenheit or Celsius, press button
to enter setting.
9.2 At Fahrenheit / Celsius row switch °C / °F to your desired format.
36
8.4 Press and hold to drag any index up or down to personalize your own sequence.
8.5 Press button and your home screen will show the indices in the sequence you set.
29°C
708mm
59mm
90mm
Change The Temperature Reading
9.3
After setting the home screen will show Fahrenheit or Celsius for all temperature and index readings.
Clear MAX / MIN Record
10. Clear recorded content
10.1 Go to Setting. Press button on “Recorded MAX / MIN” content.
10.2 Pop up menu will appear to ask your double confirmation. Select to clear the record or to cancel the action.
Clear MAX / MIN Record
10.3
9:41 AM
If is selected, the Temperature and Humidity section of “Recorded MAX / MIN” will show - - .
Connection failed or disconnected
11. Connection failed or disconnected
If your devices do not receive any signal or are disconnec­ted from the network over 3 minutes, the home screen will turn into transparent. A pop up menu will remind the user the bluetooth signal is lost or disconnected.
Low Battery / Out of Battery
12. Low battery detection
If the batteries of the RTH transmitter are getting low, above pop up menu will appear on the screen.
If the RTH transmitter is out of batteries, above pop up menu will appear on the screen.
reconnect.
WBGT Level
36
CAUTION
CAUTION
EXTREME
EXTREME
CAUTION
CAUTION
DANGER
DANGER
EXTREME
EXTREME
DANGER
DANGER
-Blank
-Caution
-Extreme Caution
-Danger
-Extreme Danger
29°C
WBGT (Wet Bulb Globe Temperature) is widely used, e.g. for sports events to measure the potential heat stress to prevent injuries replicated by temperature and humidity correlation.
Humidex Level
36
29°C
Humidex is an index to describe how hot the weather feels to the average person based on temperature and humidity correlation.
COMFORTABLE
COMFORTABLE
SOME
SOME
DISCOMFORT
DISCOMFORT
GREAT
GREAT
DISCOMFORT
DISCOMFORT
DANGEROUS
DANGEROUS
-Blank
-Comfortable
-Some Discomfort
-Great Discomfort
-Dangerous
Heat Index Level
-Blank
-Comfort
COMFORT
COMFORT
-Caution
CAUTION
CAUTION
EXTREME
EXTREME
-Extreme Caution
CAUTION
CAUTION
-Danger
DANGER
DANGER
EXTREME
EXTREME
-Extreme Danger
DANGER
DANGER
36
29°C
Heat index is an index that combines air temperature and relative humidity to determine the human perceived equivalent temperature - how hot the subject feels.
Mold Index
-Blank
-Comfort
COMFORT
COMFORT
CAUTION
CAUTION
-Pre-Caution
-Caution
PRE-CAUTION
PRE-CAUTION
36
29°C
Flu Index
Flu Index
CAUTION
CAUTION
Mold index is an index to describe the condition that may encourage mold growth based on temperature and humidity correlation.
Flu Index
-Blank
COMFORT
COMFORT
PRE-CAUTION
36
PRE-CAUTION
CAUTION
CAUTION
29°C
Flu Index
Flu Index
CAUTION
CAUTION
Flu index is an index to describe the condition if it is likely to transmit the common flu virus based on temperature and humidity correlation.
-Comfort
-Pre-Caution
-Caution
Safety advice
For your safety:
• This product should only be used as described within these
instructions.
• Unauthorised repairs, modifications or changes to the product
are prohibited.
• This product is not be used for public information, it is only
intended for home use.
Caution!
Risk of injury:
• Keep this instrument and the batteries out of reach of children.
• Batteries must not be thrown into a fire, short-circuited, taken
apart or recharged. Risk of explosion!
• Batteries contain harmful acids. Low batteries should be
changed as soon as possible to prevent damage caused by leaking. Never use a combination of old and new batteries together, or batteries of different types.
• Wear chemical-resistant protective gloves and safety glasses
when handling leaking batteries.
• Remove the batteries if you do not use the product for a long
period of time.
Important information on product safety!
• Do not place your product near extreme temperatures, vibrations
or shocks.
• Protect it from moisture.
• The transmitter is protected against splash water, but is not
watertight. Choose a shady and dry position for the transmitter.
• Check the transmission of the signal from the outdoor trans-
mitter to the smartphone (transmission range 40 m free field).
• Within ferro-concrete rooms (basements, superstructures), the
received signal is naturally weakened.
• If necessary choose another position for the transmitter.
• Clean it with a soft damp cloth. Do not use solvents or scouring
agents.
Waste disposal:
Never dispose of empty batteries and rechargeable batteries in household waste. As a consumer, you are legally required to take them to your retail store or to an appropriate collection site depending on national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compatible disposal.
Declaration of Conformity
Herewith we declare, that this wireless transmission device does comply with the essentials requirements of R&TTE Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via info@tfa-dostmann.de.
TFA Dostmann GmbH & Co. KG
Zum Ottersberg 12, D-97877 Wertheim No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice.
The product manual in all available languages and the latest technical data and information can be found by entering your product number on our homepage www.tfa-dostmann.de 02/14
RoHS
708mm